FANGZHOU FZ-821 Lead-free Glass PH electrode for protein samples
3 ceramic cores, pre-pressurized reference and Proteyle reference electrode solution, suitable for protein-containing samples, cell foster solution, TRLS buffer, hair dye, mascara, etc.
FZchina-
HANNA HI1135B PH electrode Refillable pH electrode with side arm structure and BNC connector
$ 554.00 -
FANGZHOU FZ-863 PH Glass electrode with temperature probe, suitable for high temperature solution
$ 285.00 -
FANGZHOU FZ-821 Lead-free Glass PH electrode for protein samples
$ 234.00 -
LEICI T-818-A-6 temperature electrode
$ 125.00 -
Bante920-ORP laboratory ORP meter
$ 464.00
The difficulty in testing viscous and dairy samples lies in the blockage of the junction. The former is because the sample is very viscous and hinders the seepage of the reference solution, and the latter is because the protein in the sample reacts with the reference solution to block the junction.
Viscous and dairy products measurement pH electrode series model function
Application Requirements for Viscosity and Dairy Measurements: Prepressurized Reference System, Protelytle Reference Electrolyte

Pre-pressurized reference system
There are many viscosity test samples, such as creams, lotions, hair dyes, etc. in the cosmetic industry, jams and creams in the food industry, coatings, glues, paints, and resins in the chemical industry, etc. It is often difficult to test viscous samples with conventional pH electrodes, and the response is slow. Unstable readings, poor repeatability and other issues. Because the viscous sample will block the ceramic core and prevent the reference solution from seeping out. Another situation is the test under high temperature and high pressure, and the sample solution reversely penetrates into the electrode. The pre-pressurization electrode can effectively solve the above problems. Pre-pressurization is a special electrode processing technology, which is to pre-fill a certain pressure inside the electrode to ensure that the electrolyte can slowly flow from the junction even in a very viscous solution. Exudation can also prevent the sample solution from entering the electrode, ensuring stable and repeatable testing. The figure below is a schematic diagram of the pre-pressurized electrode, and the pressure indicator tube in the figure is used to control the pressure.

dairy testing
When using a conventional pH electrode to test protein-containing dairy products and foods, the protein in the sample will react with the KCI reference solution, precipitate and block the ceramic junction.
Protelyte is an oily electrolyte that will not react with protein, and the junction of the FZ-821/823 electrode has 3 ceramic cores, which is less likely to be blocked.
Viscous and dairy product measurement pH electrode series model parameter table
| FZ | 851-S | 853-S | 851-H | 853-H | 821 | 823 |
| pH range | 0-14pH | 0-14pH | 0-14pH | 0-14pH | 0-14pH | 0-14pH |
| temperature range | -5~100℃ | -5~100℃ | 0~130℃ | 0~130℃ | -5~100℃ | -5~100℃ |
| temperature probe | none | NTC 30KΩ | none | NTC 30KΩ | none | NTC 30KΩ |
| glass film | S | S | HA | HA | S | S |
| Membrane impedance | <150MΩ | <150 MΩ | <500 MΩ | <500 MΩ | <200 MΩ | <200 MΩ |
| Junction | ceramic core | ceramic core | ceramic core | ceramic core | Ceramic core*3 | Ceramic core*3 |
| reference system | silver ion trap | silver ion trap | silver ion trap | silver ion trap | silver ion trap | silver ion trap |
| reference electrolyte | KCI gel | KCI gel | KCI gel | KCI gel | Protelyte | Protelyte |
| Shell material | lead-free glass | lead-free glass | lead-free glass | lead-free glass | lead-free glass | lead-free glass |
| electrode size | φ12*120mm | φ12*120mm | φ12*120mm | φ12*120mm | φ12*120mm | φ12*120mm |
| Interface/Cable | BNC/1m | BNC-RCA/1m | BNC/1m | BNC-RCA/1m | BNC/1m | BNC-RCA/1m |
FZchina FZ-821 PH electrodeSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | PH value |
| PH range | 0~14pH |
| Temperature range | -5~100℃ |
| Temperature probe | without |
| Glass film | S |
| Membrane Impedance | <200MΩ |
| Liquid network department | Ceramic core * 3 |
| reference type | silver ion trap |
| Reference electrolysis solution | Protelyte |
| Shell material | Lead Free Glass |
| Electrode size | Φ12*120mm |
| Connector | BNC-RCA/1m |
FZchina FZ-821 PH electrode Packing list
Electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveQB/T 2724-2005


FZ-821
FZ-823
FZ-853-H
FZ-851-H
FZ-853-S
FZ-851-S