| Lighting method | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; includes UV/exclude UV measurement; Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; includes UV/exclude UV measurement; Haze (ASTM D1003) |
| Integrating sphere size | Φ154mm |
| Lighting source | 360~780Nm Combined LED Light source, 400nm Cut-off Light source, 420nm Cut-off Light source |
| spectroscopy | Concave grating spectroscopy |
| Sensor | 256 pixel dual array CMOS image sensor |
| Wavelength Range | 360~780nm |
| wavelength interval | 10nm |
| Half bandwidth | 5nm |
| Reflectance Measurement Range | 0~200% |
| Measurement caliber | Reflection: φ 0.5mm Transmission: φ 4mm |
| Light-containing method | Reflection SCI/SCE, Transmission SCI/SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
| Other chroma metrics | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313),同色异谱指数Mt |
| Viewing Angle | 2°/10° |
| Available Light Sources | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
| display mode | Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias |
| Measurement time | Approximately 2.4s (approximately 5s for simultaneous SCI/SCE testing) |
| Repeatability | Spectroscopic reflectance: 0019 1mm/SCI, standard deviation within 0.08% chromatic value: 0019 1mm/SCI, Delta E * ab within 0.15 (after instrument preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) |
| Inter-instrument Agreement | ΔE*ab<0.25(SCI) |
| size | 370*300*200mm |
| Weight | About 9.6kg |
| Power Supply | DC 24V, 3A power adapter Power |
| Lighting source life | More than 3 million measurements in 5 years |
| Display | TFT true color 7inch, capacitive touch screen |
| Interface | USB, Bluetooth ® 5.0, print serial port |
| store data | 5000 master standards, 40,000 samples (SCI/SCE counts as one data) |
| Operating language | Simplified Chinese, Traditional Chinese, English, (customizable German, French, Spanish) |
| Operating temperature range | 0~40℃(32~104°F) |
| Storage temperature range | -20~50℃(-4~122°F) |
| Optional | Microprinters, instrument inverted test fixtures, culture dishes |
| meet the standard | CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7 |
| Other chroma metrics 2 | Staining colour fastness, fastness to color change, force, coverage, APHA/Hazen/Pt-Co (platinum cobalt index), Gardner index 8 degree gloss, 555 shade classification, haze (ASTM D1003), Saybolt (Seibert index), ASTM D1500 color standard, Chinese Pharmacopoeia color standard |
| Repeatability 2 | Spectral transmittance: 0019 8mm/SCI, standard deviation within 0.1% chromatic value: 0019 8mm/SCI, Delta E * ab within 0.18 (after instrument preheating correction, the average value of whiteboard 30 times at intervals of 5s measurement) |
None