Yoke FP6420 Flame photometer for cement industry K: 10.0mmol/L Na: 200.0mmol/L
Simultaneous detection of potassium and sodium, Interference filter spectroscopy, range K: 0.0~10.0mmol/L, Na: 0.0~200.0mmol/L, linear calibration, dual-channel LED digital display.
Yoke-
YueFeng UV756 Ultraviolet-visible Spectrophotometer with USB interface
$ 1272.00 -
YUEFENG FP6426 Flame photometer K/Ba
$ 1461.00 -
YUEFENG FP6455 Five-element Flame photometer
$ 1998.00 -
YueFeng 723N Visible Spectrophotometer Wavelength 325~ 1100nm
$ 839.00 -
JINGHUA 7600-I Dual beam of light UV-Visible Spectrophotometer deuterium lamp/tungsten lamp light source
$ 4808.00
Features
1. The appearance is small, exquisite and beautiful.
2. Dual-channel LED digital display 4-digit digital display per channel, clear readings.
3. Unique ignition gas circuit, push-button automatic ignition, fast and reliable ignition.
4. Potassium and sodium can be detected at the same time, and it has the detection function of lithium calcium.
5. Using silicon photocell detection, the measurement results are accurate and stable.
6. Small amount of sample, high sensitivity.
7. Use liquefied petroleum gas as fuel, easy to use.
8. With flameout protection function, the performance is safe and reliable.
Yoke FP6420 FP series Flame photoMeterSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | K:0.0~10.0mmol/L Na:0.0~200.0mmol/L |
| Spectroscopic method | Interference filter |
| Sexual repeability | Relative standard deviation ≤ 3 |
| linearity error | K≤0.005mmol/L、Na≤0.03mmol/L |
| Minimum measurement | ≤0.004mmol/L、Na≤0.008mmol/L |
| Response time | <8S |
| linear range | K:0. 02mmol~0.1mmol/L、Na:0.1~0.5mmol/L |
| Linear dispersion calibration | straight line method |
| Environment temperature | 10~35°C |
| Dimensions | 650*400*375*mm |
Yoke FP6420 FP series Flame photoMeter Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Color Measurement Challenges Faced by Manufacturers in the Metals Industry
- Working mechanism, common types and performance considerations of light stabilizers
- ActiveGB/T 713.2-2023
- ActiveASTM D4185-23
- ActiveGB/T 693-2024
- ActiveSL/T 788.4-2019
- ActiveSL/T 788.5-2019
- ActiveSL/T 788-2019
- ActiveHJ 668-2013
- ActiveSL/T 788.1-2019
- ActiveGB/T 6730.89-2024
- ActiveHB 20056.1-2011
- ActiveYB/T 4217.1-2010
- ActiveHJ 601-2011
- ActiveQX/T 216-2013
- Active 01010102-2006
- ActiveGB/T 15262-1994
- ActiveGB/T 15516-1995
- ActiveGB/T 16129-1995
- ActiveGB/T 32606-2016
- ActiveGB/T 40998-2021
- ActiveGB/T 8077-2023


FP6420