Yoke P614 Portable dissolved oxygen Conductivity Detector rate Measurement Instrument
Dissolve oxygen + Conductivity Detector two-in-one, automatically identify 8 kinds of Conductivity Detector standard solutions, automatic temperature compensation, automatic salinity compensation and manual air pressure compensation, high-purity water nonlinear temperature compensation function,
Yoke-
Bante DO-8 portable Dissolved Oxygen Meter with US DO100 dissolved Oxygen electrode
$ 427.00 -
HANNA HI93712-01 Photometer reagent, aluminum 100 times
$ 274.00 -
DDKSIC PCD100T touch screen desktop pH/conductivity/Dissolved Oxygen Meter
$ 1510.00 -
Bante903P-UK Portable multiparameter Water Quality Meter
$ 571.00 -
NOBOTECH ZS-680 Flow Online Suspension Meter 0-500NTU
$ 752.00
Introduction
It is used to measure the conductivity, TDS, salinity and resistivity of aqueous solution. It is suitable for industrial and mining enterprises, water treatment engineering and environmental protection industries, especially for field and field use.
Features
1. Large-screen LCD display with controllable white backlight.
2. Built-in microprocessor chip, with intelligent functions such as automatic calibration, automatic temperature compensation, data storage, function setting, automatic shutdown and low Voltage display.
3. Automatically identify 8 kinds of conductivity standard solutions, and there are two series of standard solutions to choose from: European and American series and Chinese series.
4. The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation.
5. The polarographic dissolved oxygen electrode with a new structure can measure temperature, salinity and dissolved oxygen at the same time. Equipped with a special dissolved oxygen electrode calibration set, the electrode polarization only needs 3~5 minutes.
6. Using the combined diaphragm cap, when replacing the sensitive membrane, just screw the new diaphragm cap on the electrode, which is very convenient to use.
7. Using excellent conductivity measurement technology, only one point of calibration is required, and electrodes with different cell constants are configured to meet the measurement accuracy requirements of 0.5μS/cm ~ 200 mS/cm.
8. Switchable conductivity, TDS, salinity and resistivity. TDS and salinity are calculated using polynomials to ensure the conversion accuracy of the full range.
9. Conductivity measurement mode has high-purity water non-linear temperature compensation function.
10. Humanized design: bracket design, convenient for customers to use. Anti-skid glove design, convenient for customers to operate.
11. The instrument is equipped with a temperature electrode for automatic temperature compensation.
12. The instrument complies with IP57 waterproof level, optional calibration solution and suitcase.
Yoke P614 P6 Series Conductivity Detector/Dissolved Oxygen MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | Dissolved oxygen, Conductivity Detector |
| Conductivity Detector Measurement range | (0.00~19.99)μS/cm、(20.0~199.9)μS/cm、 (200~1999)μS/cm、(2.00~19.99)mS/cm、(20.0~199.9)mS/cm |
| TDS range | 0~100g/L |
| Salinity range | 0~100ppt |
| Resistivity Measurement range | 0 ~ 100MZ · cm |
| resolution | 0.01/0.1/1μS/cm 0.01/0.1 mS/cm |
| Conductivity Detector temperature compensation range | (0~100) ℃ (automatic) |
| Conductivity Detector measurement Accuracy | Electric meter: ± 1.0% FS, matching: ± 1.5% FS |
| reference temperature | 25 ℃, 20 ℃ and 18 ℃ |
| Electrode constant | 0.1 / 1 / 10 cm-1 |
| DO range | 0~20.00mg/L(ppm) |
| DO resolution | 0.1/0.01 mg/L(ppm) 1/0.1 % |
| DO measurement Accuracy | Electric meter: ± 0.10mg/L, matching: ± 0.40mg/L |
| Response time | ≤ 30s (25 ℃, 90% Response) |
| Residual current | ≤0.1mg/L |
| Temperature compensation range | (0~99) ℃ (automatic) |
| Salinity compensation range | 0~45ppt (manual) |
| Air pressure compensation range | 0~200kPa (manual) |
| Auto calibration | Air saturated with water; water saturated with air |
| Electrode type | polarographic |
| data storage | 150 groups |
| Save content | Numbers, measurements, Measurement Units and temperature values |
| Power | 2 AA batteries (1.5V × 2) |
| Dimensions | 65*120*31mm |
| Weight | 180g |
| Suitcase Dimensions | 255×210×50mm |
| Suitcase Weight | 790g |
| Environment temperature | 5~ 35 ℃ (0.01 grade) |
| Environment humidity | ≤85% |
| Mass and safety certification | ISO9001:2000, CE和CMC |
| Protection class | IP57 |
| DO% Measurement range | 0~200.0% |
| DO% Measurement range | 0~200.0% |
Yoke P614 P6 Series Conductivity Detector/Dissolved Oxygen Meter Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Measurement method for electrophoretic coating by conductivity meter
- The correct operation method of the dissolved Oxygen Meter [including five-minute video demonstration]
- What are the water quality testing equipment required by the laboratory?
- What to do if the pH meter does not measure pH correctly?
- 5 Little Known Things About TDS in Solution
- Principles of two different measurement techniques for moisture determination
- What is a salinity meter?
- Definitions for Conductivity, Resistivity, TDS and Salinity Measurements
- How to test the hardness of copper?
- How does Holiday Detector work in coating leak detection control?
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveHJ 925-2017
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990


P614