Yoke PB-560 Plate pH/Conductivity Detector/Dissolved Oxygen Meter
Digital electrode, 3.5mm plug, temperature electrode compound to each detection electrode, no additional temperature electrode, can be equipped with digital 504ORP electrode to measure Oxidation-reducton potential.
Yoke-
DDKSIC CON201T Conductivity Detector electrode for laboratory and outdoor measurement of conventional water samples
$ 109.00 -
LEICI DDBJ-350F Portable Conductivity Meter Class 1.0, Touch Screen
$ 599.00 -
BANTE DDS-11AW Laboratory Conductivity Meter
$ 214.00 -
DDKSIC CON201 Conductivity Detector electrode for laboratory and outdoor measurement of conventional water samples
$ 96.00 -
BANTE A151-DH Laboratory conductivity /TDS/salinity/resistivity meter
$ 535.00
Introduction
One machine with multiple functions: built-in pH module, conductivity module and dissolved oxygen module
Test items: pH value/mV value/conductivity/resistivity/TDS/salinity/dissolved oxygen concentration/dissolved oxygen saturation/temperature
Features
1.5-inch LCD, 150-degree Viewing Angle, beautiful design, lightweight.
2. The compact bracket and rotating electrode rack can be fixed on the wall. The integrated design of the host bracket and electrode rack saves space. The rotating electrode rack can be rotated 360 degrees without dead angle, which is more convenient for personnel to view data.
3. Small size, instrument thickness 15mm, easy to carry. It is suitable for being carried to the field or used in the field, and can also be used in the laboratory.
4. Built-in ARM32-bit microprocessor chip, using digital filtering and slip technology to intelligently improve the response speed of the instrument and the accuracy of measurement data. The circuit board adopts SMT patch technology, which improves the reliability of product processing.
5. The button adopts CTS technology (capacitive touch sensor button), which has waterproof and anti-interference ability, good protection and durability, and the button area is easy to clean.
6. Scalability: Different electrodes can be easily and quickly replaced to measure pH, conductivity or dissolved oxygen. Both PH conductivity and dissolved oxygen can be measured with one electrode, and the temperature can be measured at the same time. The electrode only has a 3.5mm plug, which is convenient for connection and avoids the inconvenience caused by multiple plug connections.
7. The host of the instrument has a 3.5mm electrode socket, which can automatically identify the type of electrode when it is plugged in. The electrode with the built-in chip can automatically store the calibration data, and automatically retrieve the calibration data after connecting to the machine.
8. Automatic temperature compensation, can automatically identify the standard liquid. The pH can automatically identify 3 groups of standard solutions and 15 kinds of buffer solutions, and supports 1-3 point automatic calibration. The conductivity module automatically recognizes the conductivity standard solution. The dissolved oxygen module supports automatic atmospheric pressure compensation, salinity calibration, automatic zero oxygen and full oxygen calibration.
9. 3.5mm plug electrode cable, easy to connect and easy to use. (The electrode length can be customized according to customer needs)
10. 2 USB sockets, easy to charge, copy data, and connect to a computer for data transmission.
11. Can store 2000 data logs, data settings include readings, GLP data, date and time.
12. Two operating modes: extended and basic operating modes; for example: in the extended operating mode, there are 5-point calibration and 2 customized buffers can be used; in the basic mode, only 5 pre-programmed buffers and 3-point calibration are available.
The battery can be used continuously for 30 hours. Available for 2 weeks. 10 minutes automatic shutdown, the longest can be set to 30 minutes. Rechargeable lithium battery charging, support charger and mobile power charging. Battery low Voltage reminder.
Yoke PB-560 Flat three in oneSpecifications
| LIST | VALUE |
|---|---|
| pH Measurement range | -2.00 ~ 20.00pH |
| resolution | 0.1/0.01 pH |
| pH Accuracy | Electric meter: ± 0.01 pH, matching: ± 0.02 pH |
| Stability | ±0.01pH/3h |
| Temperature compensation range | -5.0~105.0℃ |
| Measuring range | 0.00~20.00μS/cm;20.0~200.0μS/cm;200~2000μS/cm; 2.00~20.00mS/cm;20.0~200.0mS/cm |
| resistivity | ( 0 ~ 100 ) MW · cm |
| TDS range | 0~100g/L |
| salinity | (0 ~ 100)ppt |
| resolution | 0.01/0.1/1μS/cm 0.01/0.1mS/cm |
| Conductivity Detector temperature compensation range | (-5.0~105.0) ℃ (automatic/manual) |
| Electrode constant | 0.1 / 1 / 10 cm-1 |
| reference temperature | 25 ℃, 20 ℃ and 18 ℃ |
| Dissolved oxygen Measurement range | (0 ~ 20.00)mg/L(ppm) (0 ~ 200.0)% |
| Dissolved oxygen resolution | 0.1/0.01 mg/L(ppm) 1/0.1 % |
| Accuracy of dissolved oxygen | Electric meter: ± 0.10 mg/L, matching: ± 0.40 mg/L |
| Dissolved oxygen temperature compensation range | (0~100) ℃ (automatic/manual) |
| Salinity compensation range | (0~45) ppt (manual) |
| Air pressure compensation range | (0~200) kPa (manual) |
| data storage | 2000 groups |
| Store content | Number, value, unit, temperature, time |
| Power | 3.7V/1800mA rechargeable lithium battery |
| Dimensions | 190×130×15mm |
| Mass and safety certification | ISO9001 2000,CE和CMC |
| Environment temperature | 5~ 35 ℃ (0.01 grade) |
| Environment humidity | ≤85% |
| Weight | 280g |
| Temperature compensation method | Manual/Automatic |
Yoke PB-560 Flat three in one Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Measurement method for electrophoretic coating by conductivity meter
- The correct operation method of the dissolved Oxygen Meter [including five-minute video demonstration]
- Determination and application of conductivity of pigment water suspension
- Differences between several common water quality testing equipment
- Application value of dissolved oxygen Detector in brewery
- American Ren's JENCO water quality analysis full series of instrument model selection table
- The principle and main functions of STIP-scan
- What factors affect ORP measurements?
- Operation steps and application of pen conductivity meter
- Principles of two different measurement techniques for moisture determination
- ActiveGB/T 8884-2017
- ActiveJJF 1714-2018
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJB/T 9366-2017
- ActiveHJ 925-2017
- ActiveSL 78-1994
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013
- ActiveGB/T 17650.2-2021
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018


PB-560