Yoke P15 Precision Conductivity Detector, dissolved oxygen two-parameter Tester, touch screen desktop
Built-in Conductivity Detector module and dissolved oxygen module, Conductivity Detector rate 0.5, dissolved oxygen polarographic film laminating method, automatic identification of 8 kinds of Conductivity Detector rate standard solutions, in line with the GLP requirements of international standards.
Yoke-
TONGAO TR-782H Water Quality Silica Tester
$ 786.00 -
TONGAO TR-308H COD Ammonia Nitrogen Total Phosphorus Turbidity Tester Water Quality Analyzer
$ 3149.00 -
HANNA HI5222 Professional desktop acidity pH/mV-ISE-temperature Tester
$ 1743.00 -
LEICI copper ion electrode calibrating solution, suitable for copper ion composite electrode
$ 106.00 -
YUEFENG SZ8125 multiparameter Water Quality Analyzer residual chlorine dioxide, compound residual chlorine total chlorine nitrite dissolved oxygen, ammonia nitrogen, iron copper
$ 845.00
Introduction
Multi-parameter measuring instrument for high-precision measurement in the laboratory, covering various electrochemical parameters such as conductivity and dissolved oxygen. It is suitable for industries such as petroleum, chemical industry, medicine, power plant and environmental protection, and has wider applications in the fields of education and scientific research.
One machine with multiple functions: built-in conductivity module and dissolved oxygen module
Test items: conductivity/resistivity/TDS/salinity/dissolved oxygen concentration/dissolved oxygen saturation/temperature
Features
1.7-inch color high-resolution (1024*600) capacitive touch screen, UI design, navigation operation experience, high sensitivity, complete parameter display, intuitive, convenient and simple to use. The host shell is made of PEEK material, which is resistant to high temperature, corrosion and aging.
2. Built-in ARM32-bit microprocessor chip, using digital filtering and slip technology to intelligently improve the response speed of the instrument and the accuracy of measurement data. The circuit board adopts SMT patch technology, which improves the reliability of product processing.
3. The main interface of the instrument can display conductivity/dissolved oxygen concentration/dissolved oxygen saturation/temperature values at the same time. Click each item module to view the detailed detection values of each detection item and perform calibration of each item.
4. Meet the GLP requirements of international standards, with intelligent functions such as automatic calibration, automatic temperature compensation, data storage, USB output, clock display, wireless printing, function setting and self-diagnosis information.
5. The instrument has a built-in Chinese and English bilingual operating system, humanized operation design, adjustable brightness of the instrument, and the temperature unit can be freely switched between ℃ and ℉. The instrument is equipped with a temperature electrode for automatic temperature compensation.
6. The built-in large-capacity storage can store 2000 sets of measurement data, the data can be stored and transferred through the U disk, and the stored data can be opened by the general office software EXELL, which is very convenient for customers to edit.
7. The instrument can be equipped with a Bluetooth module, which supports wireless Bluetooth printing, which is convenient for users to operate.
8. Based on the Wechat applet, you can view the instrument data in real time even if you download the program on your mobile phone.
9. The polarographic dissolved oxygen electrode with a new structure can measure temperature and dissolved oxygen at the same time, and the electrode polarization only needs 3~5 minutes. When using the combined diaphragm cap, when replacing the sensitive membrane, just screw the new diaphragm cap on the electrode, which is very convenient to use.
10. The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and automatic air pressure compensation.
11. Scalability: replace different electrodes (electrodes with different cell constants can be selected) to measure conductivity.
12. Automatically identify 8 kinds of conductivity standard solutions, and there are two series of standard solutions to choose from: European and American series and Chinese series. ※13. It can intelligently judge the electrode status to ensure accurate use by customers.
13. Switchable conductivity, TDS, salinity and resistivity. TDS and salinity are calculated using polynomials to ensure the conversion accuracy of the full range.
14. Comply with IP54 dust-proof and splash-proof design.
Yoke P15 Touch screen desktop 2 in 1Specifications
| LIST | VALUE |
|---|---|
| Measurement parameters | Conductivity Detector, dissolved oxygen |
| Conductivity Detector Measurement range | (0.00~20.00)μS/cm;(20.0~200.0)μS/cm; (200~2000)μS/cm;(2.00~20.00)mS/cm; (20.0~200.0)mS/cm;(200~2000)mS/cm(K=10) |
| Resistivity Measurement range | 0 ~ 100MZ · cm |
| TDS range | 0~100g/L |
| Salinity range | 0~100ppt |
| Conductivity Detector resolution | 0.01/0.1/1μS/cm、0.01/0.1/1mS/cm |
| Conductivity Detector measurement Accuracy | Electric meter: ± 0.5% FS, matching: ± 1.0% FS |
| Temperature compensation range | Manual/automatic (0~100) ℃ |
| Electrode constant | 0.1 / 1 / 10 cm-1 |
| reference temperature | 25 ℃, 20 ℃ and 18 ℃ |
| DO range | 0~20.00mg/L(ppm) |
| DO resolution | 0.1/0.01 mg/L(ppm); 1/0.1 % |
| DO measurement Accuracy | Electric meter: ± 0.10mg/L, matching: ± 0.40mg/L |
| Response time | ≤ 30s (25 ℃, 90% Response) |
| DO temperature compensation range | 0~45 ℃ (automatic) |
| Salinity compensation range | 0~45Ppt (automatic) |
| Air pressure compensation range | 80~105kPa (automatic) |
| Auto calibration | Air saturated with water; water saturated with air |
| Electrode type | polarographic |
| Temperature Measurement range | 0℃~ 100℃ |
| temperature resolution | 0.1℃ |
| Temperature measurement Accuracy | 5~ 60 ℃ range: ± 0.4 ℃, remaining range: ± 0.8 ℃ |
| data storage | 2000 groups |
| Save content | Measurement number, measurement value, temperature value, ATC or MTC status, measurement date, measurement time |
| Power | DC12V/1A |
| Communication interface | USB2.0, wireless Bluetooth (optional) |
| Dimensions | 160*190*70mm |
| Weight | 880g |
| Environment temperature | 10~30℃ |
| Environment humidity | ≤ 80 % |
| Protection class | IP54 |
| Mass and safety certification | ISO9001:2000,CE和CMC |
| DO% Measurement range | 0~200.0% |
| DO% Measurement range | 0~200.0% |
Yoke P15 Touch screen desktop 2 in 1 Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Maintenance and Maintenance of Dissolved Oxygen Electrode
- Measurement method for electrophoretic coating by conductivity meter
- Conductivity meter operation instructions
- Operation steps and application of pen conductivity meter
- Use of Colorimeters
- Definitions for Conductivity, Resistivity, TDS and Salinity Measurements
- Surface soluble salt measurement - conductivity test method
- How the Colorimeter works
- Operation and application instructions for conductivity meters
- Conductivity Detector method and precautions
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990


P15