YouKe P706 portable touch screen pH/conductivity/dissolved oxygen analyzer dissolved oxygen fluorescence method
Measure acidity + conductivity + dissolved oxygen, with fluorescence method to dissolve Oxygen electrode, automatic temperature compensation, manual salinity compensation, manual air pressure compensation function.
Yoke-
HANNA HI98130 acidity meter multiparameter pH-EC-TDS Measurement Instrument
$ 354.00 -
HANNA HI97720 calcium hardness Portable Photometer
$ 540.00 -
HANNA HI93718-01 Photometer reagent, iodine 100 times
$ 148.00 -
Qiwei ORP-2 Portable ORP Meter
$ 165.00 -
DDKSIC ORP301 composite ORP electrode for waste water, swimming pool water measurement
$ 122.00
Introduction
Multi-parameter measuring instrument for high-precision measurements in the laboratory, covering a wide range of electrochemical parameters such as pH, conductivity and dissolved oxygen. It is suitable for petroleum, chemical, power plant and environmental protection industries, and has a wider range of applications in the fields of education and scientific research.
One machine for multiple purposes: built-in pH module, conductivity module and dissolved oxygen module
Test items: pH value/mV value/conductivity/resistivity/TDS/salinity/dissolved oxygen concentration/dissolved oxygen saturation/temperature
Features
1.7-inch color high-resolution (1024*600) capacitive touch screen, UI design, navigation-based operation experience, high sensitivity, complete parameter display, intuitive, easy to use, simple. The shell of the main engine is made of PEEK material, which is resistant to high temperature, corrosion and aging.
2. Built-in ARM32-bit microprocessor chip, using digital filtering and slip technology, intelligently improve the response speed of the instrument and the accuracy of measurement data. The circuit board adopts SMT placement process, which improves the reliability of product processing.
3. The main interface of the instrument can display pH value/mV value/conductivity/dissolved oxygen concentration/dissolved oxygen saturation/temperature value at the same time.
4. In line with the GLP requirements of international standards, it has intelligent functions such as automatic calibration, automatic temperature compensation, data storage, USB output, clock display, wireless printing, function setting and self-diagnosis information.
5. The instrument has a built-in bilingual operating system in Chinese and English, humanized operation design, adjustable brightness of the instrument, and the temperature unit can be freely switched between °C and °F.
6. Built-in large-capacity storage can store 2000 sets of measurement data, the data can be stored and transferred through U disk storage, and the stored data can be opened by the general office software EXELL, which is greatly convenient for customers to edit.
7. The instrument can be equipped with a Bluetooth module, which supports wireless Bluetooth printing, which is convenient for users to operate.
8. Based on the WeChat applet, the Yoke Instrument Intelligent Internet of Things platform system can be downloaded from the mobile phone to view the instrument data in real time.
9. Equipped with a new fluorescence dissolved oxygen electrode with temperature sensor, the dissolved oxygen measurement mode has the functions of automatic temperature compensation, manual salinity compensation and manual air pressure compensation, which is more convenient to use and more accurate to measure.
10. Fluorescence dissolved oxygen sensor, electrode without membrane, no electrolyte, no polarization. The sensor does not consume oxygen, is not affected by flow rate, is maintenance-free, has a long service life, and is easy to replace fluorescent caps.
11. Scalability: Different pH probes can be easily and quickly replaced (matching electrodes can be selected for different samples) to measure pH. Replace the electrodes with different electrodes (you can choose electrodes with different electrode constants) to measure the conductivity.
12. Automatically identify 8 kinds of conductivity standard solutions, and there are two series of standard solutions to choose from: European and American series and Chinese series. 15 pH standard buffer solutions are automatically recognized, and there are three series of standard buffer solutions to choose from: European and American series, NIST series and CHINA series.
13. It can intelligently judge the electrode status to ensure that customers use it accurately.
14. Switchable conductivity, TDS, salinity and resistivity. TDS and salinity are calculated polynomially to ensure the conversion accuracy of the full scale.
15. Rechargeable lithium battery power supply, support power supply and mobile power bank charging.
16. IP54 dustproof and splashproof design.
Yoke P706 Touch screen portable three-in-one (dissolved oxygen fluorescence method)Specifications
| LIST | VALUE |
|---|---|
| PH range | (-1.99 ~ 19.99)pH |
| pH resolution | 0.1/0.01pH |
| Measurement Accuracy of pH | Electric meter: +/- 0.01pH, matching: +/- 0.02pH |
| input current | ≤1×10-12 A |
| Impedance | ≥3×10(12) Ω |
| Stability | ±0.01pH/3h |
| Temperature compensation range | Manual/automatic (0~100.0) ℃ |
| Measurement range mV | -2000mV ~ 0 ~ 2000mV |
| mV resolution | 1mV |
| Measurement Accuracy of mV | ±0.1%FS |
| EC range 1 | (0.00~20.00)μS/cm 、(20.0~200.0)μS/cm、(200~2000)μS/cm |
| EC range 2 | (2.00~20.00)mS/cm、(20.0~200.0)mS/cm、(200~2000)mS/cm(K=10) |
| Resistivity range | 0~100MΩ·cm |
| TDS range | 0~100g/L |
| Salinity range | 0~100ppt |
| Resolution | 0.01/0.1/1μS/cm,0.01/0.1/1 mS/cm |
| Accuracy | Electric meter: +/- 0.5% FS, matching: +/- 1.0% FS |
| Temperature compensation range | (0~100) ℃ (manual/automatic) |
| Electrode constant | 0.1/1/10cm-1 |
| reference temperature | 25 ℃, 20 ℃ and 18 ℃ |
| DO range | 0~20.00mg/L(ppm) |
| DOS resolution | 0.1/0.01 mg/L(ppm), 1/0.1 % |
| DO Measurement Accuracy | Electric meter: +/- 0.10mg/L, matching: +/- 0.40mg/L |
| Response time | ≤10s |
| Stability | (±0.07mg/L)/1h |
| Temperature compensation range | (0~100) ℃ (automatic/manual) |
| Salinity compensation range | 0~45ppt (automatic) |
| Air pressure compensation range | 0~200kPa (automatic) |
| Electrode type | Sensors of dissolved oxygen by fluorescence |
| Measurement range | 0℃~ 100℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | 5~ 6 0 ℃: +/- 0.4 ℃; the remaining range: +/- 0.8 ℃ |
| Data storage | 2000 groups |
| save content | Measured value number, Measured value, Temperature value, ATC or MTC status, Measurement date, Measurement time |
| Power Supply | Rechargeable lithium battery Power Supply, 3.7V/1800mA rechargeable lithium battery |
| Communication interface | USB2.0, wireless Bluetooth (optional) |
| Dimensions | 160*190*70mm |
| Environmental temperature | Environmental temperature: 5~ 35 ℃ (0.01 grade), 15~ 30 ℃ (0.001 grade) |
| Environmental humidity | ≤75% |
| Protection level | IP54 |
| Weight | 880g |
Yoke P706 Touch screen portable three-in-one (dissolved oxygen fluorescence method) Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Maintenance and Maintenance of Dissolved Oxygen Electrode
- Measurement method for electrophoretic coating by conductivity meter
- The correct operation method of the dissolved Oxygen Meter [including five-minute video demonstration]
- How to choose the right titrator for the laboratory?
- Use of Colorimeters
- How to choose the dissolved oxygen measurement method: optical method, current method, polarographic method?
- Water quality testing instrument FAQ collection
- How the Colorimeter works
- How to monitor the pH and other water quality parameters of aquarium water?
- What is the importance of dissolved oxygen testing in water quality testing?
- ActiveGB/T 8884-2017
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveHJ 1147-2020
- ActiveHJ 925-2017
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 18920-2020
- ActiveGB/T 1576-2018
- ActiveGB/T 17650.2-2021
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016


P706