Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> STIP-scan> Yoke> Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method)

      Yoke YG-01 button desktop dissolved oxygen analyzer, fluorescence method

      Fluorescence dissolved oxygen analyzer, range 0-20.00ppm, concentration 0-200%, with fluorescence dissolved Oxygen electrode, electrode without film, no electrolysis solution, no polarization.

      Brand
      SKU: NB039444
      China Yoke
      Model
      VS
      Genuinegoods
      • Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method)Overview

      • Specifications
      • Comments
      • FAQs
      YG-01
      Button type desktop Dissolved Oxygen Meter (fluorescence method)
      • Yoke YG-01 button desktop dissolved oxygen analyzer, fluorescence method
      • Yoke YG-01 button desktop dissolved oxygen analyzer, fluorescence method Figure 1
      • Yoke YG-01 button desktop dissolved oxygen analyzer, fluorescence method Figure 2
      Fluorescence dissolved oxygen analyzer, range 0-20.00ppm, concentration 0-200%, with fluorescence dissolved Oxygen electrode, electrode without film, no electrolysis solution, no polarization.

      Features

      1. It adopts 6.5-inch LED screen with complete and intuitive parameter display and user-friendly interface design, which is convenient for users to operate and use.

      2. Omron long-life light-touch button is adopted, which is convenient and durable, and can reach more than 100,000 times.

      3. Meet the GLP requirements of international standards, with intelligent functions such as automatic calibration, automatic temperature compensation, data storage, USB output, clock display, wireless printing, function setting and self-diagnosis information.

      4. The built-in large-capacity storage can store 2000 sets of measurement data, the data can be stored and transferred through the U disk, and the stored data can be opened by the general office software EXELL, which is very convenient for customers to edit.

      5. The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and automatic air pressure compensation.

      6. The instrument can be equipped with a Bluetooth module, which supports wireless Bluetooth printing, which is convenient for users to operate.

      7. Equipped with a new type of dissolved oxygen electrode with a temperature sensor, the dissolved oxygen measurement mode has the functions of automatic temperature compensation, manual salinity compensation, and manual air pressure compensation, which is more convenient to use and more accurate to measure.

      8. Fluorescent dissolved oxygen sensor, the electrode has no membrane, no electrolyte, no polarization. The electrode does not need to consume oxygen, is not affected by the flow rate, is free from maintenance, has a long service life, and is easy to replace the fluorescent cap.

      9. Comply with IP54 dust-proof and splash-proof design.

      VS

      Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method)Specifications

      LIST VALUE
      Measurement parameters Concentration, saturation, temperature
      Display 6.5 inch LED screen
      DO range 0.00~20.00mg/L(ppm)
      DO resolution 0.01/0.1
      DO measurement Accuracy Electric meter: ± 0.10mg/L; matching: ± 0.40mg/L
      DO measurement Accuracy ±1%
      DO% Measurement range 0.0~200%
      DO% resolution 0.1%
      DOAccuracy ±2.0%FS
      Temperature Measurement range (0~100)℃
      temperature resolution 0.1℃
      temperature relative Accuracy ±0.1℃
      Temperature compensation range (0~100) ℃ (automatic/manual)
      Salinity compensation range 0~45ppt (manual)
      Air pressure compensation range 0~200kPa (automatic)
      Barometric resolution 0.1
      Air pressure Accuracy ± 2%
      Stability (±0.07mg/L)/1h
      Response time ≤10s
      data storage 2000 groups, external USB for Mass storage
      Communication interface USB, wireless Bluetooth (optional)
      Environment temperature 5~40℃
      Power 12V1A (110-220, 50Hz-60Hz adapter)
      Dimensions 160*190*70mm
      Weight 880g
      Working Relative Humidity 5~85%

      Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method) Packing list

      complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      This execution standard
      [A]
      JJG 291-2018
      [Q]
      It is written above that it is not affected by Flow velocity. Do you not need Stirrer?
      [A]
      Fluorescence does not consume oxygen and does not require stirring
      [Q]
      Will bubbles in the sensitive film affect the test results when the dissolved oxygen meter is tested?
      [A]
      Yes, the surface of the sensitive film can not accumulate bubbles, otherwise it will affect the Test accuracy.
      [Q]
      Does Sensors need to be cleaned every day?
      [A]
      No, wash it every 30 days.
      [Q]
      How long does it take to replace the fluorescent cap?
      [A]
      It is recommended to replace it once a year.
      +Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method) Big data
        +Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method)Similar products
        +Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method)Knowledge
        +Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method)Standard
        +Navigation
        Yoke
        Yoke YG-01 button desktop dissolved oxygen analyzer, fluorescence method
        Service
        Focus on online sales of Lab Testing Instruments