Yoke YG-01 button desktop dissolved oxygen analyzer, fluorescence method
Fluorescence dissolved oxygen analyzer, range 0-20.00ppm, concentration 0-200%, with fluorescence dissolved Oxygen electrode, electrode without film, no electrolysis solution, no polarization.
Yoke-
HANNA HI70080P TDS calibrating solution 800 mg/L (ppm) /20ml/bag (25 bags/box)
$ 141.00 -
JINGQI WD8204 Aluminum Tester
$ 481.00 -
LEICI bromine ion electrode calibrated solution, suitable for bromine ion composite electrode
$ 106.00 -
JINGQI WD8219 Arsenic Tester
$ 481.00 -
TONGAO TR-106H residual chlorine total chlorine Tester
$ 786.00
Features
1. It adopts 6.5-inch LED screen with complete and intuitive parameter display and user-friendly interface design, which is convenient for users to operate and use.
2. Omron long-life light-touch button is adopted, which is convenient and durable, and can reach more than 100,000 times.
3. Meet the GLP requirements of international standards, with intelligent functions such as automatic calibration, automatic temperature compensation, data storage, USB output, clock display, wireless printing, function setting and self-diagnosis information.
4. The built-in large-capacity storage can store 2000 sets of measurement data, the data can be stored and transferred through the U disk, and the stored data can be opened by the general office software EXELL, which is very convenient for customers to edit.
5. The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and automatic air pressure compensation.
6. The instrument can be equipped with a Bluetooth module, which supports wireless Bluetooth printing, which is convenient for users to operate.
7. Equipped with a new type of dissolved oxygen electrode with a temperature sensor, the dissolved oxygen measurement mode has the functions of automatic temperature compensation, manual salinity compensation, and manual air pressure compensation, which is more convenient to use and more accurate to measure.
8. Fluorescent dissolved oxygen sensor, the electrode has no membrane, no electrolyte, no polarization. The electrode does not need to consume oxygen, is not affected by the flow rate, is free from maintenance, has a long service life, and is easy to replace the fluorescent cap.
9. Comply with IP54 dust-proof and splash-proof design.
Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method)Specifications
| LIST | VALUE |
|---|---|
| Measurement parameters | Concentration, saturation, temperature |
| Display | 6.5 inch LED screen |
| DO range | 0.00~20.00mg/L(ppm) |
| DO resolution | 0.01/0.1 |
| DO measurement Accuracy | Electric meter: ± 0.10mg/L; matching: ± 0.40mg/L |
| DO measurement Accuracy | ±1% |
| DO% Measurement range | 0.0~200% |
| DO% resolution | 0.1% |
| DOAccuracy | ±2.0%FS |
| Temperature Measurement range | (0~100)℃ |
| temperature resolution | 0.1℃ |
| temperature relative Accuracy | ±0.1℃ |
| Temperature compensation range | (0~100) ℃ (automatic/manual) |
| Salinity compensation range | 0~45ppt (manual) |
| Air pressure compensation range | 0~200kPa (automatic) |
| Barometric resolution | 0.1 |
| Air pressure Accuracy | ± 2% |
| Stability | (±0.07mg/L)/1h |
| Response time | ≤10s |
| data storage | 2000 groups, external USB for Mass storage |
| Communication interface | USB, wireless Bluetooth (optional) |
| Environment temperature | 5~40℃ |
| Power | 12V1A (110-220, 50Hz-60Hz adapter) |
| Dimensions | 160*190*70mm |
| Weight | 880g |
| Working Relative Humidity | 5~85% |
Yoke YG-01 Button type desktop Dissolved Oxygen Meter (fluorescence method) Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Maintenance and Maintenance of Dissolved Oxygen Electrode
- The correct operation method of the dissolved Oxygen Meter [including five-minute video demonstration]
- Ren's JENCO 9010M dissolved Oxygen Meter instruction manual
- Application value of dissolved oxygen Detector in brewery
- Basic knowledge of conductivity, resistivity, TDS and salinity measurements
- How to choose the dissolved oxygen measurement method: optical method, current method, polarographic method?
- How to choose the right titrator for the laboratory?
- How to monitor the pH and other water quality parameters of aquarium water?
- Water quality testing instrument FAQ collection
- What is the importance of dissolved oxygen testing in water quality testing?
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveJB/T 14242-2022
- ActiveHJ 925-2017
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 7489-1987
- ActiveGB/T 11913-1989
- ActiveGB/T 18920-2020
- ActiveGB/T 1576-2018
- ActiveGB/T 33328-2016


YG-01