QIWEI PHB-4 pH Tester, Portable Microcomputer 0~14pH
PHB-4 pH Tester with E201-C-W plastic shell PH three composite electrode or 018 temperature electrode, PHB-4 pH meter can perform automatic temperature compensation PH test, while measuring PH value, mV value and temperature value.
QiWei-
Bante220-CN portable pHmeter with E201 plastic pH electrode
$ 256.00 -
DDKSIC 201PRO composite pH electrode - double-splice design for water sample measurement in wastewater, pool environment monitoring and more
$ 113.00 -
E-PHSCAN-LT-10K pH electrode
$ 105.00 -
LEICI PHBJ-260 portable smart pH meter pH/mV/temperature 0.01 class
$ 509.00 -
HANNA HI7001L pH standard solution calibrated value 1.68pH (25 ℃) 500ml
$ 116.00
Overview
Qi WeiPHB-4 The ph Tester is a portable microcomputer pH meter, controlled by a microprocessor, with a measurement accuracy of 0.01 pH.The PHB-4 PH meter is equipped with E201-C-W molded case PH triple composite electrode or 018 temperature electrode, and the PH meter can perform automatic temperature compensation PH test.The PHB-4 PH meter is equipped with high-quality imported integrated components, which is accurate, stable and reliable, simple and convenient to operate, and is suitable for laboratory measurement of pH and mV value of solutions.
Application
PHB-4 ph Tester can be used in light industry, chemical industry, food, environmental protection, and education and scientific research departments.
Measurement method
1. Measurement of pH value
1) Measure the temperature of the solution with a thermometer first (PHB-4 contains a temperature electrode that can automatically detect the temperature);
2) Press the increase button ∧or decrease button∨ adjust the temperature value of the instrument accurately;
3) WASH THE ELECTRODE OF THE PH METER AND PUT IT INTO THE SOLUTION, STIR IT SLIGHTLY, PLACE IT STILL, AND READ IT WHEN THE MEASURED VALUE IS STABLE, AND THE OBTAINED READING IS THE PH VALUE.
2. Measurement of mV value
1) Switch the PH meter to the "mV" setting first.
2) Connect the ORP electrode or ion electrode (sold separately) and insert it into the solution to be measured.When the measured value is stable, the resulting reading is the ORP value or the potential value of the ion electrode.
pH Tester calibration options
Qi WeiPHB-4 pH TesterThe built-in intelligent chip can be used for one-, two-point or three-point automatic calibration. There are three cases: If the measurement accuracy ≤ 0.1 pH, only pH is used If the measurement range is only in the acidic range (≤7pH), you can choose pH7 and pH4 calibration, if the measurement range is only in the alkaline range (≥7pH), you can choose pH7 and pH10 calibration, if the measurement range is relatively wide, or when the pH electrode is used for a long time and there is aging phenomenon, you should choose three-point calibration, which will make the measurement accuracy higherPHB-4 pH TesterThe slope is adjusted to be consistent with the pH sensor.
Actual picture of the product



QiWei PHB-4 pH meter (portable microcomputer)Specifications
| LIST | VALUE |
|---|---|
| Measurement parameters | pH, mV, temperature |
| PH range | 0~14pH |
| Measurement Accuracy of pH | ±0.01pH |
| Resolution | pH: 0.01pH/Temperature: +/- 1 ℃ |
| Measurement range | 0~60 ℃ manual/automatic compensation |
| Stability (zero drift) | ≤ 0.01 pH +/- 1 word/2h |
| Impedance | >1x1012Ω |
| Data storage | without |
| Power Supply | 1.5V battery/4 pcs |
| Dimensions | 180*80*30mm |
| Weight | About 0.5Kg |
| Standard electrode reagent | E201-C-W plastic case PH temperature electrode; PH standard calibrated sample; No. 7 DC1.5V battery 4 |
| Environmental temperature | 0~40℃ |
| Allowable Relative Humidity | <85% |
| Solution temperature compensation range | 0~60℃ |
| Power Consumption | 2W |
| Measurement Accuracy | ±1℃ |
| Measurement range | 0~60℃ |
| Measurement range mV | ±1999mV |
QiWei PHB-4 pH meter (portable microcomputer) Packing list
Host x1, Buffer reagent x3, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 2394-2024
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- Active 098-2007
- ActiveGB/T 8077-2023
- ActiveGB/T 1601-2023
- ActiveGB/T 18920-2020
- ActiveGB/T 1576-2018
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010


PHB-4