Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Surface Tensiometer> FangRui> FangRui Q1000 platinum plate method Surface TensioMeter

      FANGRUI Q1000 Surface Tensiometer platinum plate method, range 1000mN/m accuracy 0.01mN/m

      Platinum plate method, range 0~1000mN/m, accuracy of 0.01mN/m, automatic measurement, using high-precision electromagnetic force Sensors, can test liquid density, with LED lighting.

      Brand
      SKU: NB039699
      China FangRui
      Stock
      Loading…
      Price
      $ 3702.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • FangRui Q1000 platinum plate method Surface TensioMeterOverview

        • Specifications
        • Comments
        • FAQs
        Q1000 platinum plate method
        Surface TensioMeter
        • FANGRUI Q1000 Surface Tensiometer platinum plate method, range 1000mN/m accuracy 0.01mN/m
        • FANGRUI Q1000 Surface Tensiometer platinum plate method, range 1000mN/m accuracy 0.01mN/m Figure 1
        • FANGRUI Q1000 Surface Tensiometer platinum plate method, range 1000mN/m accuracy 0.01mN/m Figure 2
        Platinum plate method, range 0~1000mN/m, accuracy of 0.01mN/m, automatic measurement, using high-precision electromagnetic force Sensors, can test liquid density, with LED lighting.

        Features

        1. The Q series tensiometer provides many expansion modules to expand the application range of the instrument, which is used to measure various characteristics of the surface and interface, which greatly improves the flexibility of its use. The main measurement principle is to accurately obtain the force between the measuring accessory or the sample to be measured when it is wetted by a liquid, the instrument uses standard methods including the DuNoüy ring method, the Wilhelmy plate method To measure the surface and interfacial tension of liquids. In addition, with the necessary optional accessories, the instrument can also be used to accurately measure the density of liquids.

        2. The spacious sample room is equipped with a transparent glass sliding door, which can protect the room from disturbing air flow. A built-in electronic level helps to fine-tune the sample stage for precise force measurements.

        3. The built-in measurement program can control the sample stage to ensure that there is no human interference in the measurement process. The running speed can be adjusted according to the experimental requirements and can be accurately repeated. The use of dynamic, smooth-running drives eliminates negatively affecting vibrations. In addition, the long-term drift of the force sensor is reduced to a minimum.

        4. Through the 7-inch touch screen, simple and intuitive operation can be realized. Intuitive operation on the touch screen is a hallmark of the new generation of tensiometers, allowing easy control of the sample stage and other components both before and during a measurement.

        5. The built-in measurement data management menu is convenient for viewing data and supports external printer operation. All measurement data files can be transferred through the U disk to be converted into Excel files, which is convenient for management, recording and arrangement of measurement data.

        6. The machine program has a password management function to ensure that the data can be traced and prevent data modification and accidental deletion.

        Application

        • Evaluation of Surfactant Effectiveness and Efficiency by Measuring Critical Micelle Concentration

        • Wetting properties of tablets, active pharmaceutical ingredients and excipients

        • Wettability of paints and coatings

        • Oil aging degree detection

        • Coating wettability and adhesion

        • Cosmetic Development

        • Study on Wetting Properties of Ink

        Transparent measurement and data management software ST Flash

        1) The simple operation of the Q series tensiometer is closely combined with the clear and clear user guidance of the software. Our ST Flash software supports easy results management through automatic summary diagrams, comprehensive measurement reports and transparent data organization functions, and also supports CMC analysis and calculation.

        FANGRUI Q2000 Surface Tensiometer Details Figure 1


        2) Support data collection, and can mark the data for easy viewing and comparison.

        3) The collected data is saved in TXT file format, which is convenient for viewing and conversion, and the graphic file is generated in PDF format for printing.

        FANGRUI Q2000 Surface Tensiometer Details Figure 2

        4) Support simultaneous comparison of up to 8 sets of data.

        FANGRUI Q2000 Surface Tensiometer Details Figure 3

        5) ST Flash software provides a toolkit for analyzing CMC concentration.

        6) The software supports Chinese and English operation and display.

        Standards

        ASTM D971 Standard Test Method for Interfacial Tension of Oil-Water by Ring Method

        ASTM D1331 Standard Test Method for Surface and Interfacial Tension of Surfactant Solutions

        ASTM D1417 Standard Method for Testing Synthetic Rubber Latex

        DIN EN 14210 Surfactants - Determination of interfacial tension of surfactant solutions by the stirrup or suspension ring method

        DIN EN 14370 Surfactants - Determination of surface tension

        ISO 304 Surfactants - Determination of surface tension by the pulling film method

        ISO 1409 Plastics/rubber — Polymer dispersions and rubber latexes (natural and synthetic) — Determination of surface tension by the ring method

        ISO 6889 Surfactants - Determination of surface tension by the pulling film method

        VS

        FangRui Q1000 platinum plate method Surface TensioMeterSpecifications

        LIST VALUE
        Measuring method Platinum plate method
        Measurement range of surface tension 0~1000mN/m
        Surface tension Accuracy 0.01mN/m
        Liquid density range 0~3.000g/cm3
        Density Accuracy 0.001g/cm3
        Operation mode Automatic lifting, automatic measurement
        Lifting speed 0~300mm/min can be adjusted arbitrarily
        Temperature Measurement Range -40 ℃~ 250 ℃ (PT100 Temperature Sensors are required)
        Display mode 7-Inch touchscreen, direct data reading
        data mode Data storage/view/print support
        Measurement time Regular within 60 seconds
        Interface RS232 (printer) or USB flash drive
        Data processing software Standard ST Flash software
        Dimension 47*24.5*47.5cm
        Horizontal adjustment method Electronic level adjustment
        Net Weight 18kg
        Power supply Voltage 110V or 220V, 50W
        Meet the standard ASTM D971、ASTM D1331、ASTM D1417、DIN EN 14210、DIN EN 14370、ISO 304、ISO 1409、ISO 6889

        FangRui Q1000 platinum plate method Surface TensioMeter Packing list

        host X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Our laboratory mainly do surfactant CMC analysis, do you have any recommended surface tensiometer?
        [A]
        The Q1000 platinum plate method surface tensiometer has a built-in special CMC analysis toolkit, and the software can automatically generate summary charts and comprehensive reports, which are suitable for evaluating the effectiveness and efficiency of surfactants. Measurement accuracy is also as high as 0.01mN/m to ensure the accuracy of the data.
        [Q]
        We would like to choose a fully functional and easy-to-operate surface tensiometer, which is mainly used for Coating and ink wettability research. Do you have any recommendations?
        [A]
        You can consider FANGRUI Q1000, which can measure not only surface/interfacial tension, but also liquid density through the expansion module, which is suitable for studying the wetting and spreading characteristics of Coatings and inks. In operation, it is equipped with a 7-inch Touchscreen, the interface is intuitive, and the supporting ST Flash Software supports Chinese and English. Data management is convenient. It can compare multiple sets of data at the same time, which is suitable for rapid testing and Data analysis in the R & D process.
        [Q]
        Testing oil and drug liquid tension is the main one, can it be used?
        [A]
        With Q1000 + Temperature Control Accessories + Platinum Ring
        FangRui
        FANGRUI Q1000 Surface Tensiometer platinum plate method, range 1000mN/m accuracy 0.01mN/m
        Service
        Focus on online sales of Lab Testing Instruments