Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> PH Meter> LeiCi> LeiCi PT-11 pH meter (acid-base test pen)
      LeiCi PT-11 pH meter (acid-base test pen)

      LEICI PT-11 Pen pH meter (acid-base test pen) Regular pen tip

      LEICI PT-11 pen pH meter is a kind of acid and alkali test pen, conventional pen, pen pH meter is suitable for water, food, human body, clothing and daily chemical PH value detection.

      Brand
      SKU: NB003974
      China LeiCi
      Model
      VS
      Genuinegoods
      • LeiCi PT-11 pH meter (acid-base test pen)Overview

      • Specifications
      • Comments
      • FAQs
      PT-11
      pH meter (acid-base test pen)

      Introduction

      Leici PT-11 pen PH meter, also known as pH Tester, is a pen type PH meter with small size, accuracy of ±0.2pH value, and good waterproof and dustproof properties.The different nibs of the PT-11 pen PH meter are suitable for different applications, there are two kinds of conventional pen nibs and flat pen nibs, and the measurement range is 0~14.pH.PT-11 pen PH meter has the function of automatic shutdown which can extend the service life of the battery, and the durability is very good, which is suitable for measuring the PH value of daily water, food, human body, clothing, daily chemical products, etc.

      Features

      1、The PT-11 pen PH meter has a professional waterproof and dustproof rating, and the durability is very good.

      2. It has the functions of automatic reading, automatic shutdown and prolonging battery life.

      3. There are flat plates, conventional (spherical), and tapered pen heads, which can be measured anytime and anywhere.

      4. The measurement is convenient and direct, simple and easy to use.

      Product Structure

      The structure of PT-11 pen PH meter includes: protective cap, measuring end, instrument housing, display window, switch button, and battery box.

      Boot method

      1、The PT-11 pen PH meter is powered by 4 AG5 1.5V button batteries, which are already installed in the pH Tester.

      2. Press the on/off button 1 time,The PH meter is turned on and enters the measurement state;The pen PH meter chirps once to prompt the power on, and the model number is displayed: "PT-11" enters the measurement state.

      3. If there is no button operation for 45s continuously, the PT-11 pen PH meter will be automatically turned off.

      Shutdown method

      Press the switch for more than 3 seconds, and the pen PH meter will prompt the word "OFF" and turn it off. After that, the measuring end is cleaned with pure water, gently spun dry and stored with an electrode protective cap.

      How to use:

      1. Take an appropriate amount of the measured sample and clean the measuring end, and gently spin off the residual sample on the measuring end after cleaning. (Sampling is to prevent cross-contamination of the tested sample)

      2. Gently immerse the measuring end in the measured solution, the depth of the measured solution needs to be immersed in the measuring end, shake it gently, and press the switch button once.

      3、PT-11 Pen PH Meter chirps once, and displays the word "on", indicating the start of measurement, the pen PH meter will automatically measure, automatically judge, and flash the measured PH value.

      4. After the reading is stable, the PT-11 pen PH meter will automatically lock the measured value, stop flashing, and tweet 3 times to prompt the user to read.

      5. If the measurement is repeated, press the on/off button again to repeat the measurement.

      Actual picture of the product

      Ray Magnetic PT-11 Pen PH Meter (Acid and Base Test Pen) Detail drawing of conventional and flat two kinds of pen heads

      Application of different nibs

      Substances are often detectedPH value detection method
      aqueous solutionSampling for direct detection, recommendedConventional (spherical)probe
      Household flavoringsSampling for direct detection, recommendedConventional (spherical)probe
      dairy productSampling for direct detection, recommendedConventional (spherical)probe
      SkincareSampling for direct detection, recommendedflatprobe
      textilesDetection after partial wetting,Recommended useflatprobe
      skin
      Direct detection, recommendedflatprobe
      Fruits/vegetables1. After sampling and grinding, directly or with a certain amount of water for testing, it is recommended to use a spherical probe; 2. For direct measurement, it is recommended to use a tapered pen tip
      Meat1. For surface measurement, it is recommended to use a flat probe; 2. For internal measurement, it is recommended to use a tapered pen tip


      VS

      LeiCi PT-11 pH meter (acid-base test pen)Specifications

      LIST VALUE
      PH range 0~14.0pH
      PH Measurement Accuracy ±0.2pH
      Resolution 0.1pH
      pen Conventional/Spherical
      Measurement range 0~50℃
      Allowable Relative Humidity <85%

      LeiCi PT-11 pH meter (acid-base test pen) Packing list

      Acid-base test pen x1, manual x1, certificate x1, outer Encasement box x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      When do I need to calibrate my pH meter?
      [A]
      Hello! The following situations need to re-calibrate the pH meter, including placing it for a long time; high frequency of use; after replacing the battery; high accuracy requirements.
      LeiCi
      LEICI PT-11 Pen pH meter (acid-base test pen) Regular pen tip
      Service
      Focus on online sales of Lab Testing Instruments