DAQTECH DT-60 Tunnel Furnace Temperature Tester 6 Channels -40.0~1370.0 ℃
Six-channel, temperature measurement from -40.0 to 1370.0 ℃, using wired transmission, supports cold node temperature correction, can store up to 16 sets of data, and can export temperature data reports to Excel for editing.
DAQTECH-
Rennes LN-60K Furnace temperature tracker 6 channels 400 ℃ 1 hour
$ 1454.00 -
TQC CX2030 Probe Connector CX2030 Clamp Workpiece Surface Thermocouple
$ 431.00 -
TQC CX2069 furnace temperature probe, air Probe type: magnetic maximum temperature: 300 ℃/570 ° F
$ 425.00 -
TQC CX2065 rapid temperature probe, maximum temperature: 300 ℃/570 ° F measurement use: workpiece surface/air
$ 312.00 -
DAQTECH DT-100 Furnace temperature tracker 10 channel temperature tracker
$ 2443.00
Introduction
The special temperature measurement system for industrial furnaces is widely used in the coating and heat treatment industries to measure and map the temperature curves of metal products in normalizing furnaces, annealing furnaces, nitriding furnaces, tempering furnaces, and so on. Through this system, users can set and optimize the temperature process, regularly monitor the temperature of metal products and workpieces, and their performance in key high-temperature processes. The key to obtaining good performance of the product in the heat treatment process depends on the process control of the metal heating process. An incorrect time/temperature profile will affect the distribution structure of metal molecules and directly reduce the performance of metal products. With the DaTeoy temperature test system, the process can be monitored without interrupting the normal production process. The Recorder passes through the industrial furnace heating equipment, and can obtain the temperature test curve of up to 16 points on the surface of the workpiece at one time. At the same time, the wireless real-time synchronous data recording function is optional.
Analysis System Advantages
1. Set the temperature and transportation speed of the oven temperature zone
2. The time between any two temperature values
3. The slope between any two temperature values
4. Maximum temperature and arrival time
5. Horizontal temperature line, vertical time line and the time between the two times
6. Test date and time
7. Input of company name, product name and remarks
8. The temperature data report can be exported to Excel for editing
9. Insert picture function to make the position of temperature test point clear at a glance
10. The software clears the memory data of the instrument
11. Three starting modes: manual and specified temperature

Thermometer Advantages
• Up to 8 types of probes to choose from
• Calibrated with standard Voltage and provides cold junction temperature correction
• Real-time wireless/wired data reception (optional)
•Instrument power off, intelligently save data when power off
• Can test multiple times, store up to 16 sets of data
•Using USB communication port, fast download and charging, fully charged and sustainable use for 50 hours
•Various indicator lights indicate various application states of the instrument, one-button operation, easy to learn and use

DAQTECH DT-60 Tunnel Furnace temperature TesterSpecifications
| LIST | VALUE |
|---|---|
| Number of channels | 6 channels |
| Probe Type | K type thermocouple (optional) |
| temperature Measurement Range | -40.0~1370.0 ℃ (optional) |
| temperature measurement Accuracy | ±1 ℃ |
| resolution | 0.1 ℃ |
| Storage Capacity | 2008888 data points |
| Recorder size | 145*60*20 mm |
| Insulation box size | Height 16 cm |
| Power | DC3.7V~DC4.2V |
| Connectivity | wired |
| Sampling frequency | 0.2~ 200.00 seconds |
| data transmission | Wired transmission/wireless transmission (optional) |
| continuous testing | Can be tested multiple times, store up to 16 sets of data |
| Start mode | Button start, delayed start, temperature start |
| Instrument power consumption | 12mAh |
| Instrument temperature resistance | 80.0 ℃ (Maximum Internal Operating Temperature of Recorder) |
| radio frequency | 1.0~100.00 seconds (optional) |
| Stop mode | Press button to stop |
| Battery level | 600mA |
| Calibrated mode | Voltage calibrated, temperature calibrated |
| Measurement time | Heat box temperature 300 degrees measurement time 120min or 400 degrees measurement time 60min |
DAQTECH DT-60 Tunnel Furnace temperature Tester Packing list
Furnace temperature tester X1, setting software X1, Thermocouple X1, communication data cable X1, heat insulation box X1, instrument box X1, manual X1, warranty card X1, certificate X1, high temperature tape X1, scissor X1, calibrate report X1, high temperature gloves X1