BOSEAN K-G60 (C2H4O) Industrial Acetaldehyde Gas Alarm Detector
Fixed, measure combustible gas (C2H4O), range 0-100PPM, multi-parameter LCD digital display, full software calibrate, semiconductor nano-process, infrared remote control remote operation, up to 8 meters.
Bosean-
HONEYEAGLE HNAG1000-HCL Fixed Hydrogen Chloride Detector 0-100PPM
Login -
GUOYUGRA GY/VGD-200-4M-G (C6H6/C7H8/C8H10/EX) On-line Gas Detector for refineries
$ 1041.00 -
HONEYEAGLE HNAG1000-SO2 Online sulfur dioxide Detector 0-1PPM
$ 758.00 -
BH-60-HCN (with display + alarm) Fixed HCN Gas Detector 0~10ppm
$ 257.00 -
GUOYUGRA GY/VGD-200-R32-G refrigerant, refrigerant Detector, difluoromethane detection 0-1000ppm
$ 630.00




















Bosean K-G60(C2H4O) Stationary Gas DetectorSpecifications
| LIST | VALUE |
|---|---|
| range | 0~100ppm |
| Optional range | 0~100ppm |
| resolution | 1/0.1PPM |
| alarm point | Low: 20PPM High: 50PPM |
| Sensors | Electrochemistry, Catalytic combustion, Semiconductor, PID Light Ion, Infrared Gas Sensors |
| Installation method | Wall-mounted, pipeline type (thread size: M35X1.5mm), circulation type, pump suction type optional |
| Transmission method | Standard 4-20mA; Standard RS485 Model: Standard MODBUS RTU Protocol: Optional 433MHz Wireless Transmission Function |
| Working Voltage | DC24V±15% |
| Detection Accuracy | ≤±3%F.S |
| linearity error | ≤±1%F.S |
| Response time | ≤20s |
| Zero drift | ≤±1%(F.S/年) |
| recovery time | ≤20s |
| Explosion-proof sign | Exd II T6 GB |
| Explosion-proof Certificate number | CNEx16.0449 |
| Protection class | IP65 |
| Connectivity | M20x1.5、G1/2 |
| Connection Cable | 3X1.5mm2 Shielding Cable |
| Operating Pressure | 86 ~ 106Kpa |
| relay | Two sets of relay outputs, touchpoint container: 30VDC 2A/220VAC 0.3A |
| Operating Temperature | -20~50℃ |
| Operating Humidity | ≤ 95% RH, no condensation |
Bosean K-G60(C2H4O) Stationary Gas Detector Packing list
Complete-built unit X1, Encasement box X1, Charger X1, Calibration cover X1, Manual X1, Certificate X1, Warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHJ 872-2017
- ActiveJB/T 13109-2017
- ActiveJB/T 11937-2014
- ActiveJB/T 11621-2013
- ActiveGB/T 3392-2023
- ActiveGB/T 20936.3-2017
- ReplacedGB 12358-2006


K-G60(C2H4O)