CHINA Humidity Test Chamber -60 ℃/408L
Volume 408L, temperature control -60 ℃~ 150 ℃, Interior size 800 * 600 * 850mm, Temperature fluctuation ≤ ± 0.5 ℃, Temperature uniformity ≤ ± 2 ℃.
HuiTai-
KESIONOTS KS-HW150A coating humidity chamber 25~ 100 ℃/150L
$ 4610.00 -
Lugong ST-80LC Humidity Chamber thermostatic Test Chamber -60 ℃~ + 150 ℃
$ 3537.00 -
ZKHS GDS-500D high-low temperature Humidity Test Chamber -60~150 ℃/500L
$ 9398.00 -
HUITAI LHS-100HC humidity chamber -5~ 80 ℃/100L
$ 1866.00 -
YIHENG BDW-86L770 ultra-low temperature freezer 770L/-50~ -86 ℃
$ 8151.00











Introduction
The function of the Test Chamber is to provide a test environment such as constant high-low temperature humidity and alternating high-low temperature humidity; Including refrigeration system, heating system, humidification/water system, air duct system, control system, system protection device, etc.
Constant temperature and humidity testing machine, also known as environmental testing machine, can accurately simulate low temperature, high temperature, high temperature and high humidity, low temperature and low humidity and other complex natural environments, suitable for electronics, electrical appliances, batteries, plastics, food, paper products, vehicles, metals, chemicals, building materials, research institutes, inspection and quarantine bureaus, universities and other industry units for quality control testing.
Test chamber body
1. Structural form
The integral structure, that is, the Test Chamber, the refrigeration system, the heating/humidification system, the air conditioning system, the electrical control cabinet, and the refrigeration unit are a whole, the refrigeration unit is located at the bottom of the box, and the electrical control part is placed on the side of the Test Chamber for easy operation.
2. a box
a) In the air duct mezzanine at one end of the studio, heat/humidifier, refrigeration evaporator, blower motor, fan blade and other devices are distributed; b) The Test Chamber workshop is made of 1mm thick SUS304 stainless steel plate, and enclosure is made of 1mm thick stainless steel.
Meet the criteria
GB11158、GB10589-89、GB10592-89、GB/T10586-89、GB/T2423.1-2001、GB/T2423.2-2001、GB/T2423.3-93、GB/T2423.4-93、GB/T2423.22-2001、IEC60068-2-1.1990、IEC60068-2-2.1974、GJB150.3、GJB150.4、GJB150.9etc.
Test chamber refrigeration system
Refrigeration principle
The refrigeration part is the main part of the cold source generated by the equipment, which provides the required cooling capacity for the cooling, low temperature and constant temperature of the equipment, and the refrigeration system is automatically turned on according to the different test states of the equipment to provide cooling capacity for the corresponding test process, so as to achieve the purpose of the performance indicators of the equipment.
Refrigeration system components
1. Compressor:The refrigeration system is mainly a compressor, this scheme we use the French Taikang fully enclosed compressor, 2.2, oil separator: whether the compressor has refrigeration oil, will directly affect its life
3. Condensing evaporator:Adopting the Swedish "Alfa Laval" currently in the world
4. Vibration reduction:Compressor spring vibration reduction is adopted, and the overall secondary vibration reduction of the refrigeration system is adopted;
5. Refrigeration evaporator:The evaporator is located in the air duct interlayer at one end of the Test Chamber and is forced to ventilate by a blower motor
Touch controllers
1. LCD touch panel, screen intercom input data, temperature and humidity can be programmed at the same time
2. It can display the curve, display the set value curve, and the actual running curve;
3. Programmable, program group up to 120 groups;
4. The interface between Chinese and English can be converted;
5. It has the function of date and time adjustment, scheduled start, shutdown and screen lock.

HuiTai NBC-LHS-408L Humidity Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -60~150℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Temperature Uniformity | ≤±2℃ |
| Humidity control range | 20~98%R.H |
| Humidity Deviation | ≤ ± 2%~ 3% R. H (above 75% R. H); ± 5% R. H (below 75% R. H) |
| Interior size | 800*600*850mm |
| Dimensions | 1380*1850*1250mm |
| Interior Volume | 408L |
| Cooling rate | 0.7~1℃/min |
| Heating rate | 2~3℃/min |
| Noise | ≤65dB |
| wind speed | 1.7~2.5m/s |
| Humidity Deviation | ≤3% |
| Heating rate | RT + → 150 ℃ │ 40min (no-load nonlinear) |
| Cooling rate | RT +~ -60 ℃ │ 65min (no-load nonlinear) |
| Humidity fluctuation | ±3%R.H |
| Humidity Deviation | ≤3% |
| Inner box material | SUS304 stainless steel |
| Enclosure Material | Stainless steel plate atomized (SUS #304) or cold plate paint (optional) |
| Thermal insulation material | Rigid Polyurethane Foam and Glass Cotton |
| Box door window | 260X340x40mm 3-layer vacuum layer |
| Box door | Single door, single window, left open, handle on the right |
| Circulatory system | (1) 90W motor 1 (2) Stainless steel extended shaft (3) Multi-wing fan blade (SIRCCO FAN) |
| Refrigeration system | Fully dense compressor imported from France |
| refrigerant | Environmentally friendly refrigerant R404A |
| Condenser | Fin type with cooling motor |
| Condenser | Fin type multi-stage automatic load Capacity adjustment |
| expansion system | Capacity Controlled Refrigeration System |
| Humidity Control Accuracy | ±1%R.H |
| Controller Resolution | Temperature ± 0.1, Humidity 1% R.H. |
| Temperature slope | 0.1~ 9.9 can be set |
| Temperature and humidity conversion output | 4~20MA |
| Temperature and humidity input signal selection | PT 100Ω × 2 (dry and wet bulbs) |
| Available program groups | Up to 100 groups |
| Available memory Capacity | Total 5000SEGMENTS |
| Command, repeability | Each command can be up to 9999 times |
| Environment temperature | 0~35℃ |
| Environment temperature | 5~35℃ |
| Environment humidity | Not more than 85% |
| atmospheric pressure | 86106Kpa |
| Natural drain | There must be no protrusions in the middle of the drain pipe, and there must be no extreme inclination of the floor of the house |
| Power | Single-phase electricity 6.5KW 380V 50HZ |
| temperature control Accuracy | ±0.1℃ |
HuiTai NBC-LHS-408L Humidity Test Chamber Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveSJ/T 10454-2020
- ActiveGB/T 43489-2023
- ActiveGB/T 38948-2020
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 37382-2019
- ActiveGB/T 11158-2008
- ActiveIEC 60068-2-1-1990
- ActiveGJB 150.3A-2009
- ActiveGB/T 2423.22-2002
- ActiveGB/T 2423.4-2008
- AbolishGB/T 2423.34-2005
- AbolishGB/T 2423.25-2008
- ActiveGJB 150.9A-2009
- ActiveGB/T 2423.3-2016


NBC-LHS-408L