LEICI DZB-712 multiparameter Water Quality Analyzer measurement conductivity/dissolved oxygen concentration /PH/temperature value
The LEICI DZB-712 multiparameter Water Quality Analyzer has a pH rating of 0.01 and a conductivity of 1.0.
LeiCi-
YUEFENG SZ8127 multiparameter STIP-scan can measure 11 kinds of water quality parameters
$ 957.00 -
JINGQI WD8205 Hexavalent Chromium Tester
$ 481.00 -
LEICI Fluorine ion electrode calibrating solution, suitable for fluorine ion composite electrode
$ 106.00 -
JINGQI WD8103 Nitrate Tester
$ 481.00 -
HANNA HI7036L TDS calibrated solution 12.41 ppt (g/L)/500ml
$ 117.00
Introduction
Thunder Magnetic portable multi-parameter Water Quality AnalyzerDZB-712All are multi-functional multi-parameter Water Quality Analyzer, Water Quality Analyzer has IP65 protection level, low power consumption, especially suitable for field and other occasions to detect aqueous solutions, can simultaneously measure conductivity, dissolved oxygen concentration, PH value, temperature value and other values, Chinese interface, easy to operate. thereintoDZB-712The multi-parameter Water Quality Analyzer has a PH level of 0.01 and a conductivity of 1.0, which is suitable for users with different accuracy needs, and the appearance of the instrument is the same.
Features and advantages
1. Thunder magnetismDZB-712 multi-parameter Water Quality Analyzer adopts LCD display with backlight, and the operation language is Chinese, which is simple and convenient.
2. The measurement data conforms to GLP specifications, and can support data storage, deletion data, printing data, and data review, and can store up to 2200 sets of data.
3. Realize manual/automatic temperature compensation function.
4. It has standard USB communication interface and REX data acquisition software, which can be connected and communicated with PC.
5. It has IP65 protection level and low-power design, which is suitable for testing in field places.
Introduction to the functions of the module
1. Conductivity measurement module function
1)DZB-712 multi-parameter Water Quality AnalyzerIt supports the measurement of conductivity, resistivity, TDS, and salinity.
2) Automatic calibration, automatic range switching, can calibrate the cell constant or TDS conversion coefficient. thereintoThe DZB-718 supports 2-point calibration.
2. PH/ion measurement module function
1) Automatically identify 10 kinds of buffer solutions, allowing self-built standard solution sets.
2) Able to automatically calibrate 1-5 points, manual/automatic temperature compensation is possible.
3) Provide a variety of commonly used ion modes such as: H+、Ag+、Na+、K+、NH4+、Cl-、F-etc., the user can also customize the ion mode.
4) Provide a variety of ion concentration units, such as ug/L, mg/L, g/L, mol/L, mmol/L, PX, etc., to achieve automatic switching.
5)DZB-712Multi-parameter Water Quality AnalyzerDirect concentration measurement mode is available
3. Dissolved oxygen measurement module function
It has the functions of automatic zero oxygen calibration and full calibration, and can realize two calibration methods: air pressure calibration and salinity calibration.
Actual picture of the product

LeiCi DZB-712 Multiparameter Water Quality Analyzer (Portable)Specifications
| LIST | VALUE |
|---|---|
| Instrument level | pH: 0.01 grade; conductivity: 1.0 grade |
| Measurement parameters | Conductivity Detector, dissolved oxygen, pH/pX, temperature |
| pH/PX Measurement range | (-2.00~20.00)pH/pX |
| ORP Measurement range | ±1999.9mV |
| Ion concentration Measurement range | (0~19990) Optional units: pX, mol/L, mmol/L, g/L, mg/L, ug/L |
| Conductivity range | 0.000μS/cm~199.9mS/cm |
| Resistivity range | 0.00Ω·cm~20.00MΩ·cm |
| TDS range | 0.000mg/L~100g/L |
| Salinity range | 0.00~8.00% |
| DO range | 0.00~19.99mg/L |
| DO% Measurement range | 0.0~199.9% |
| Response time | ≤ 45s (90% Response at 20 ℃) |
| Measurement range | -5.0~135.0℃ |
| pH/pX resolution | 0.01pH/pX |
| ORP resolution | 0.1mV |
| DOS resolution | 0.01mg/L |
| DO% resolution | 0.10% |
| Temperature Resolution | 0.1℃ |
| pH/pX intrinsic error | +/- 0.01pH/pX +/- 1 word |
| ORP intrinsic error | ±0.1%FS |
| EC intrinsic error | ±1.0%FS |
| Resistivity intrinsic error | ±1.0%FS |
| TDS intrinsic error | ±1.0%FS |
| Salinity intrinsic error | ±0.2% |
| DO intrinsic error | ±0.30mg/L |
| DO% intrinsic error | ±10.0% |
| Temperature intrinsic error | +/- 0.3 ℃ +/- 1 word |
| Temperature compensation range | Automatic, PH: (0.0~100.0) ℃; Conductivity Detector: (0.0~100.0) ℃; dissolved oxygen: (0.0~40.0) ℃ |
| Power Supply | 4 AA alkaline batteries |
| Dimensions | 210*100*45mm |
| Weight | 0.5kg |
LeiCi DZB-712 Multiparameter Water Quality Analyzer (Portable) Packing list
Multiparameter analyzer x1, DJS-1C-F platinum black electrode (waterproof type) x1, E-201-C-F electrode (waterproof type) x1, T-818-B-4-F type temperature sensor (waterproof type) x1, DO-957-F type dissolved Oxygen electrode (waterproof type) x1, pH standard buffer pH4,7,9 each x5,5 dry battery x4, miniUSB communication cable x1, REX instrument communication disc x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How are dissolved oxygen analyzers and pH meters used in sewage treatment?
- Uncertainty Analysis of Fast Moisture meter measurement
- ActiveGB/T 693-2024
- ActiveJJF 1714-2018
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 126-2009
- Active 271-2018
- ActiveSL 144.2-2008
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 17650.2-2021


DZB-712