CHINA Programmable Humidity Test Chamber NBC-LHS-1000H -20 ℃/1000L
Temperature control -20 ℃~ 150 ℃, programmable, volume is 1000L, LCD touch screen, can display the set value Linear dispersion, 304 stainless steel inner box, French Taikang compressor refrigeration system.
HuiTai-
Lugong ST-408LD Humidity Chamber -70 ℃~ + 150 ℃
$ 5605.00 -
CHINA NBC-150L-40 Semiconductor Humidity Chamber paint panel -40 ℃/150L
$ 2678.00 -
Aipei AP-HX-800A Programmable high and low temperature heating and humidity box 800L/0 ℃
$ 7020.00 -
CHINA NBC-50L-20 Programmable High and Low Temperature Humidity chamber Temperature circulation box -20 ℃/50L
$ 2367.00 -
KESIONOTS KS-HW80L programmable humidity chamber -70 ℃/80L
$ 5527.00











Introduction
The function of the Test Chamber is to provide a test environment such as constant high-low temperature humidity and alternating high-low temperature humidity; Including refrigeration system, heating system, humidification/water system, air duct system, control system, system protection device, etc.
Constant temperature and humidity testing machine, also known as environmental testing machine, can accurately simulate low temperature, high temperature, high temperature and high humidity, low temperature and low humidity and other complex natural environments, suitable for electronics, electrical appliances, batteries, plastics, food, paper products, vehicles, metals, chemicals, building materials, research institutes, inspection and quarantine bureaus, universities and other industry units for quality control testing.
Test chamber body
1. Structural form
The integral structure, that is, the Test Chamber, the refrigeration system, the heating/humidification system, the air conditioning system, the electrical control cabinet, and the refrigeration unit are a whole, the refrigeration unit is located at the bottom of the box, and the electrical control part is placed on the side of the Test Chamber for easy operation.
2. a box
a) In the air duct mezzanine at one end of the studio, heat/humidifier, refrigeration evaporator, blower motor, fan blade and other devices are distributed; b) The Test Chamber workshop is made of 1mm thick SUS304 stainless steel plate, and enclosure is made of 1mm thick stainless steel.
Meet the criteria
GB11158、GB10589-89、GB10592-89、GB/T10586-89、GB/T2423.1-2001、GB/T2423.2-2001、GB/T2423.3-93、GB/T2423.4-93、GB/T2423.22-2001、IEC60068-2-1.1990、IEC60068-2-2.1974、GJB150.3、GJB150.4、GJB150.9etc.
Test chamber refrigeration system
Refrigeration principle
The refrigeration part is the main part of the cold source generated by the equipment, which provides the required cooling capacity for the cooling, low temperature and constant temperature of the equipment, and the refrigeration system is automatically turned on according to the different test states of the equipment to provide cooling capacity for the corresponding test process, so as to achieve the purpose of the performance indicators of the equipment.
Refrigeration system components
1. Compressor:The refrigeration system is mainly a compressor, this scheme we use the French Taikang fully enclosed compressor, 2.2, oil separator: whether the compressor has refrigeration oil, will directly affect its life
3. Condensing evaporator:Adopting the Swedish "Alfa Laval" currently in the world
4. Vibration reduction:Compressor spring vibration reduction is adopted, and the overall secondary vibration reduction of the refrigeration system is adopted;
5. Refrigeration evaporator:The evaporator is located in the air duct interlayer at one end of the Test Chamber and is forced to ventilate by a blower motor
Touch controllers
1. LCD touch panel, screen intercom input data, temperature and humidity can be programmed at the same time
2. It can display the curve, display the set value curve, and the actual running curve;
3. Programmable, program group up to 120 groups;
4. The interface between Chinese and English can be converted;
5. It has the function of date and time adjustment, scheduled start, shutdown and screen lock.

HuiTai NBC-LHS-1000H Humidity Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -20~150℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Temperature Uniformity | ≤±1.5℃ |
| Humidity control range | 20~98%R.H |
| Humidity fluctuation | ±2%R.H |
| Humidity Uniformity | ±3.0%R.H、-2.0%R.H |
| Power | 3f 380V |
| Interior size | 1000*1000*1000mm |
| Dimensions | 1510*1560*1860mm |
| Interior Volume | 1000L |
| Cooling rate | 1 ℃/min (no-load nonlinear) |
| Heating rate | 3 ℃/min nonlinear no-load |
| Heating rate | RT + → 150 ℃ │ 40min (no-load nonlinear) |
| Cooling rate | RT + → -40 ℃ │ 60min (no-load nonlinear) |
| Inner box material | USU #304 Mirror Stainless Steel (1MM thick) |
| Enclosure Material | Cold rolled steel spray treatment or gauze surface stainless steel (thickness 1MM) |
| Refrigeration system | Using original French Taikang compressor, environmentally friendly refrigerants R404A and R23A, fin type condenser with heat dissipation evaporator, evaporator: fin type multi-stage automatic load Capacity adjustment |
| Controller | Using original TEM series Control system such as TEMI880 color Chinese and English touch condenser or TEMI300 English button Controller |
| Safety Devices | No fuse switch, compressor high pressure, overheating, overcurrent protection, over temperature protection, fan overload protection, fuse, dry burn protector, water shortage alarm protection |
| Communication function | 232 or 485 online, with software CD and 1 set of connecting data cable, optional USB interface |
| Display | LCD touch panel |
HuiTai NBC-LHS-1000H Humidity Test Chamber Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The Critical Study of Coating Specimen State Adjustment and Test Temperature Humidity
- Principle, application and selection of field effect transistor programmable Humidity Chamber
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveJG/T 25-2017
- ActiveGB/T 43489-2023
- ActiveGB/T 23711.2-2019
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 15905-1995
- ActiveGB/T 11158-2008
- ActiveIEC 60068-2-1-1990
- ActiveGJB 150.3A-2009
- ActiveGB/T 2423.22-2002
- ActiveGB/T 2423.4-2008
- AbolishGB/T 2423.34-2005
- ActiveGJB 150.9A-2009
- ActiveGB/T 2423.3-2016
- ActiveGB/T 10589-2008


NBC-LHS-1000H






