RONGHUA RHDCY-12S Water Bath Nitrogen Evaporator 12-well sample, no oxygen condensing
The 12-hole design can process multiple samples at the same time, the temperature control accuracy is up to +/- 0.5 ℃, and the nitrogen consumption can be adjusted to 330ml/min/sample by digital temperature control method to achieve rapid anaerobic condensation.
RONGHUA-
RONGHUA RHDCY-12 Dry Nitrogen Evaporator 12-hole nitrogen purge instrument, temperature control accuracy +/- 0.5 ℃
$ 480.00 -
HUXI HPT-8 Automatic quantitative nitrogen blowing condenser 8L/600W
$ 7222.00 -
YIHENG BMD200-2 Nitrogen Evaporator sample condensed prepative independent temperature control air needle
$ 1122.00 -
RONGHUA RHDCY-24 Dry Nitrogen Evaporator 24-hole nitrogen purge instrument, digital temperature control +/- 0.5 ℃
$ 674.00 -
HUXI ST-12 Water Bath Nitrogen Evaporator Sample condensing temperature control heating
$ 455.00
Introduction
The water-bath Nitrogen Evaporator adopts purge and trap technology, and can control the temperature of the sample to heat at the same time, and use inert gas such as nitrogen to quickly, controllably and continuously blow to the surface of the sample to achieve rapid anaerobic concentration of the sample solution. The method is time-saving, convenient and accurate.
Water bath Nitrogen Evaporator series parameters
| Product number | 12 holes | 24 holes | 36 holes |
| Number of samples processed | 12 | 24 | 36 |
| Tube size | Ф16mm | Ф16mm | Ф16mm |
| Nitrogen consumption | 330ml/min/sample (adjustable) | 330ml/min/sample (adjustable) | 330ml/min/sample (adjustable) |
| Barometer | 0-15L/min | 0-15L/min | 0-15L/min |
| Standard number of heating blocks | One test tube rack | One test tube rack | One test tube rack |
| Temperature control accuracy | ±0.5℃ | ±0.5℃ | ±0.5℃ |
| Temperature control range | Room temperature---100℃ | Room temperature---100℃ | Room temperature---100℃ |
| Temperature control method | Digital temperature control | Digital temperature control | Digital temperature control |
| Dimensions | 340*200*460 | 340*200*460 | 340*200*460 |
| power | 600W | 600W | 600W |
| weight | 7KG | 7.5KG | 8.5KG |
RONGHUA RHDCY-12S Nitrogen EvaporatorSpecifications
| LIST | VALUE |
|---|---|
| Number of processed samples | 12 |
| Testtube size | Ф16mm |
| Nitrogen consumption | 330Ml/min/sample (adjustable) |
| Gas flow meter | 0~15L/min |
| Standard number of heating blocks | Tuberack one |
| temperature control Accuracy | ±0.5℃ |
| Temperature range | RT+~100°C |
| Temperature control method | Digital temperature control |
| Dimensions | 340*200*460 |
| power | 600W |
| Weight | 7KG |
RONGHUA RHDCY-12S Nitrogen Evaporator Packing list
host X1, certificate X1, manual X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


RHDCY-12S
RHDCY-36S