YIHENG GRX-9013A Hot Air Disinfection Box Power is 650W
High-precision temperature control (RT + 10200 ℃/RT + 10250 ℃, 0.1 ℃ Temperature resolution , +/- 1 ℃ Temperature Fluctuation), low energy consumption (650W), flexible Timer Range (19999 minutes), suitable for various Environmental temperatures (540 ℃), and equipped with 2 shelves.
YiHeng-
Kenton DZF-6050S constant temperature vacuum Drying Oven, stainless steel liner
$ 840.00 -
BOZHEN DHG-9420A vertical Forced Air Drying Oven
$ 1475.00 -
YIHENG DZF-6055 Vacuum Oven
$ 881.00 -
YIHENG DZF-6050B Vacuum Oven (for biology)
$ 817.00 -
SANFA DHG-9202-1 Electric thermostatic Drying Oven 300 ℃/70L
$ 380.00
Introduction of GRX-9013A hot air disinfection box
Yiheng GRX-9013A hot air disinfection box is a small-sized desktop hot air disinfection box with a temperature control range of RT+10~200°C and a temperature resolution of 0.1°C. The input power of GRX-9013A hot air disinfection box is 650W, and the inner tank size is 250x260x250mm.
Features
1. Accurate: High-precision microcomputer liquid crystal display temperature controller, accurate and reliable temperature control.
2. Rapid: heating up quickly, forced convection, hot and dry air directly passes through the heated object, and the drying and disinfection time is significantly shortened.
3. Safety: If the temperature exceeds the limit, it will be automatically interrupted to ensure the safety of personnel and instruments.
4. Convenience: The GRX-9013A hot air disinfection box can be set from the instrument to realize the three-speed adjustable fan speed and Timer Control. The shelf can be moved to facilitate cleaning in the box, which makes the operator feel convenient everywhere.
Pictures

YiHeng GRX-9013A Hot Air SterilizerSpecifications
| LIST | VALUE |
|---|---|
| Power | AC 220V 50Hz |
| Temperature range | RT+10~200°C/RT+10~250°C |
| Temperature Resolution | 0.1℃ |
| Environment temperature | 5~40℃ |
| Input power | 650W |
| Interior size | 250*260*250mm |
| Dimensions | 530*480*420mm |
| Shelf (std.) | 2pcs |
| Timer | 1~9999min |
| Temperature fluctuation | ±1℃ |
| Net Weight | 20kg |
| Gross Weight | 22Kg |
| Packing size | 670*530*510mm |
YiHeng GRX-9013A Hot Air Sterilizer Packing list
host x1, instruction manual x1, packing list x1, warranty x1, warranty card x1, fuse x2, shelf x2, shelf x2.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 23850-2024
- ActiveJB/T 20033-2011
- ActiveGB/T 13835.4-2009
- ActiveGB/T 32710.10-2016
- ActiveHG/T 5164-2017
- AbolishGB/T 5211.3-1985
- ActiveJB/T 5520-1991
- ActiveQB/T 1552-1992


GRX-9013A