CHINA CTG-800-1500FN Paint Layer Thickness Gauge, Integrated dual-use Standard Type
Magnetic induction, eddy current integration, automatic identification of the substrate, super wear-resistant cemented carbide probe, measuring thickness up to 1500μm, measurement accuracy ± 2% + 1μm, reaction speed up to 0.3 seconds/time, with temperature compensation.
YiBai-
CHINA CTG-802-1500FV cylindrical coating Thickness Gauge, split iron-based large V type, suitable for surface measurement
$ 226.00 -
List MEGA-CHEK Basic platings Thickness Gauge
$ 1392.00 -
German EPK MiniTest 600 B-F magnetic platings Thickness Gauge, thickness: 0~3000μm
$ 846.00 -
Defelsko N0S split 0 ° probe, thin coating
$ 1017.00 -
German EPK MikroTest F6 McCourt coated platings Thickness Gauge, thickness measurement: 0~1000μm
$ 800.00
Introduction
CTG-800-1500 Coating Thickness Gauge is a combination of magnetic and eddy current. It can automatically identify magnetic or non-magnetic substrates and switch automatically. It can quickly, without damage, and accurately measure the thickness of coatings and coatings. It can be used in both laboratory and engineering site. This instrument can be widely used in the detection fields of automobile industry, manufacturing industry, metal processing industry, chemical industry, commodity inspection and so on. It is the instrument required by the material protection profession.
CTG-800-1500 coating Thickness Gauge has backlight, large-screen digital display, single-point and multi-point calibration and other functions, and this product is resistant to high-low temperature, anti-drop, probe wear-resistant (more than 500,000 times), and test stability Well, the test speed is fast and it is suitable for various measurement environments. Its Specifications fully comply with national and international standards.
The Fe function detects the thickness of non-magnetic coatings on all magnetic substrates, such as paint applied to steel, iron, powder coating, plastic, porcelain, chrome, copper, zinc, etc.
The NFe function detects the thickness of insulating coatings on all non-magnetic substrates, such as lacquer, plastic, porcelain, etc. These coatings must be applied to non-magnetic metal substrates such as aluminum, copper, brass or stainless steel.
Features
●Measurement method: F magnetic induction, N eddy current
●The spring guide sleeve probe with super wear-resistant carbide probe can ensure the probe has constant pressing force and stable sampling value when measuring on hard or rough surface;
●Can quickly and automatically identify magnetic substrate and non-magnetic substrate;
●High precision, good stability, can measure 1-5μm ultra-thin coating;
●The measurement speed can reach 0.3 seconds/time;
●Large screen digital display is clearer;
●Two shutdown modes: manual shutdown and automatic shutdown;
●Wide measurement range and high resolution;
●Digital backlight display, no parallax, suitable for night use;
●Measurement mode: single measurement/continuous measurement;
●With metric and imperial unit conversion function, realize μm / mil conversion;
●The shell and internal structure are newly designed to enhance the product's appearance, drop resistance and impact resistance;
●Touch measurement accuracy is good.

YiBai CTG-800-1500FN Integrated dual-use Standard Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic induction + eddy current |
| Measuring range | 0 ~ 1500m |
| margin of error | ±2% |
| resolution | 0.1mm | 1mm |
| Minimum radius of curvature | F: convex: 1.5mm/concave 25mm; N: convex: 3mm/concave 50mm |
| thinnest matrix | 0.3mm |
| Test environment | Non-magnetic coating on magnetic substrates |
| probe | Integrated probe |
| Power | 2 AA batteries (AAA) |
| Display screen | 4-Bit digital backlight LCD |
| Operating Temperature | -10-50℃ |
| Relative Humidity | <80% |
| Total Weight | 54G (without battery) |
| Complete-built unit size | 101*61*26mm |
YiBai CTG-800-1500FN Integrated dual-use Standard Coating Thickness Gauge Packing list
Host X1, standard piece X6, base X2, manual X1, battery X2, warranty card X1, certificate X1, portable case X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Characteristics of Solvent-Based Acrylic Coatings
- Definition and Applicable Criteria for Dry Film Thickness
- Destructive dry film thickness test and non-destructive dry film thickness test which is good? What standard is applied?
- Conductive and non-conductive coating thickness measurement and testing skills
- Frequently Asked Questions for Thickness Gauges in 2022
- What should I do if there is a negative number when the customer reports the Thickness Gauge measurement?
- How does the split coating Thickness Gauge measure the thickness of the three-proof paint of the aluminum LED lamp? [Video Demonstration]
- Eletroplating zinc layer thickness measurement application
- Coating Thickness Gauge measurement nano-coating coating thickness
- Application of Film Thickness Gauge in glue thickness measurement
- ActiveGB/T 44757-2024
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 13448-2019
- ActiveJJG 818-2018
- ActiveISO 2808-2019
- ActiveGB/T 4956-2003
- AbolishGB/T 13448-2006
- AbolishISO 4042-1999
- ActiveQC/T 484-1999
- AbolishGB/T 4956-1985
- ActiveGB/T 5209-1985
- AbolishJB/T 5673-1991
- ActiveGB/T 4957-2003


CTG-800-1500FN Integrated dual-use Standard
CTG-800-3000FN Integrated dual-use Standard