YIHENG LHS-150SC Constant Temperature and Humidity Chamber (simple type) 10~45 ℃/150L
Temperature range No humidification: 10~45 ℃; Humidification: 15~ 45 ℃, temperature resolution 0.1 ℃, Temperature fluctuation High temperature +/- 1 ℃, low temperature +/- 2 ℃, humidity control range 60~85% R.H, humidity deviation +/- 5~ 8% R.H, input power 550W, Operating Environment temperature 5~ 35 ℃, continuous working time is not less than 180 hours.
YiHeng-
HUDA programmable Humidity Chamber QT-E702-225B60 -60 ℃/225L
$ 3091.00 -
KESIONOTS KS-HW80C doors and windows humidity chamber -20~ 150 ℃/80L
$ 4361.00 -
CHINA NBC-80L-20 high-low temperature heating and humidity Chamber, paint panel -20 ℃~ 150 ℃/80L
$ 2371.00 -
CHINA NBC-225L-60 programmable constant temperature and humidity laboratory -60 ℃/225L
$ 3506.00 -
CHINA NBC-408L-60 Drug constant temperature and humidity test Room temperature heating and Humidity Chamber -60 ℃/408L
$ 5512.00
Introduction of LHS-150SC Constant Temperature and Humidity Chamber
LHS-150SC constant temperature and Humidity Chamber is a simple constant temperature and Humidity Chamber of Yiheng. It adopts mirror stainless steel liner and semi-circular corners, which has the advantages of anti-corrosion and easy cleaning. The input power of the LHS-150SC constant temperature and Humidity Chamber is 550W, and the temperature control range is 15~45℃/10~45℃. RS45 interface is optional to connect to the PC to monitor the temperature and humidity parameters.
Features
1. The LHS-150SC constant temperature and Humidity Chamber adopts a new fluorine-free design.
2. The mirror stainless steel liner is adopted, the four corners are semi-circular and easy to clean, and the distance between the shelves in the box is adjustable.
3. Humidity sensor and microcomputer temperature and humidity controller are selected to ensure accurate and reliable temperature and humidity control.
4. There is an independent temperature limit alarm system, which will automatically stop when the temperature exceeds the limit, so as to ensure the safe operation of the experiment without accidents. (optional)
5. It can be equipped with RS485 interface for connecting to a computer, which can record the changes of temperature and humidity parameters, but it cannot be connected to a printer. (optional)
6. There is a test hole with a diameter of 25mm on the left side of the box, which is convenient for experimental operation and testing. (optional)
Note: The independent temperature limit alarm system, RS485 interface, and test hole are all optional accessories, and users need to purchase them separately.
Pictures

YiHeng LHS-150SC Constant Temperature and Humidity ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | No humidification: 10~45 ℃; Humidification: 15~ 45 ℃ |
| Temperature Resolution | 0.1℃ |
| Temperature fluctuation | High temperature +/- 1 ℃, low temperature +/- 2 ℃ |
| Humidity control range | 60~85%R.H |
| Humidity Deviation | ±5~8%R.H |
| Input power | 550W |
| Environment temperature | 5~35℃ |
| Continuous Operating Time | Not less than 180 hours |
| Power | AC220V 50HZ |
| Interior size | 500*370*800mm |
| Dimensions | 600*575*1325mm |
| Shelf (std.) | 3pcs |
| Optional accessories | This model is simple and cannot be equipped with a printer. The humidity fluctuates greatly and cannot operate for a long time. |
| Net Weight | 150Kg |
| Gross Weight | 205Kg |
| Packing size | 930*1720*810mm |
YiHeng LHS-150SC Constant Temperature and Humidity Chamber Packing list
Constant Temperature and Humidity Chamber x1, instruction manual x1, packing list x1, certificate x1, warranty x1, warranty card x1, shelf x2, gauze x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- IncomingGB/T 19787-2025
- ActiveIEC
- ActiveIEC
- ActiveASTM
- ActiveGB/T 2423.34-2024
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- 2058-2023
- ActiveQX/T 16-2020
- ActiveGB/T 38534-2020
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 41166-2021
- ActiveGB/T 35157-2017
- AbolishGB/T 2423.34-2005
- ActiveGB/T 8013.1-2018
- ActiveHG/T 5180-2017
- ActiveGB/T 2423.3-2016
- AbolishHG/T 3658-1999