YIHENG LHS-50CH Humidity Chamber (equilibrated control) 10~85 ℃/50L
Temperature range 10~85 ℃, temperature resolution 0.1 ℃, Temperature fluctuation +/- 1.0 ℃, humidity control range 80~95% R.H, humidity deviation +/- 3% R.H, input power 1450W, Operating Environment temperature 5~ 30 ℃, Power Supply AC220V50HZ, LHS-100CB is: AV380V 50HZ, Interior size 350 * 300 * 500mm, dimensions 720 * 620 * 725mm, shelf (std.) 2pcs.
YiHeng-
KESIONOTS KS-HW80F Experimental Constant Temperature and Humidity Chamber -60~ 150 ℃/80L
$ 5030.00 -
YIHENG BPS-100CL Humidity Chamber -10~100 ℃/100L
$ 3497.00 -
YIHENG BDW-86L490 ultra-low temperature freezer 490L/-50~ -86 ℃
$ 6261.00 -
Aipei AP-HX-150D programmable high and low temperature damping heat test chamber 150L/-60 ℃
$ 6149.00 -
HZAOC GDJS-100A high-low temperature Humidity Cyclic Chamber -20~150 ℃/100L
$ 6724.00
Introduction of LHS-50CH Constant Temperature and Humidity Test Chamber
LHS-50CH constant temperature and Humidity Test Chamber is Yiheng's popular constant temperature and Humidity Chamber. It is fluorine-free and environmentally friendly. It is equipped with an independent temperature limit alarm system. If the temperature exceeds the limit, the operation will be automatically interrupted to ensure the safety of the operation. The humidity control range of LHS-50CH constant temperature and Humidity Test Chamber is 80~95%RH, the temperature control range is 10~85℃, and the input power is 1450W. The temperature resolution of the LHS-50CH is 0.1°C.
Application of LHS-50CH constant temperature and Humidity Test Chamber
LHS-50CH constant temperature and Humidity Test Chamber is suitable for sterility tests, stability checks of pharmaceuticals, textiles, food processing, etc., as well as raw material performance, product packaging, and product life tests of industrial products.
Features and advantages
1,The LHS-50CH constant temperature and Humidity Test Chamber adopts a new fluorine-free design.
2. The mirror stainless steel liner is adopted, the four corners are semi-circular and easy to clean, and the distance between the shelves in the box is adjustable.
3. The microcomputer temperature and humidity controller adopts the TMHM balanced temperature and humidity regulation method, which is stable in operation, accurate in temperature and humidity control, and safe and reliable. Key components such as controllers and compressors are all imported products.
4. There is an independent temperature limit alarm system, which will automatically stop when the temperature exceeds the limit, so as to ensure the safe operation of the experiment without accidents.
5. There is a test hole with a diameter of 25mm on the left side of the box, which is convenient for experimental operation and temperature measurement.
6. It can be equipped with a Recorder to record the temperature and humidity operation curve. (optional)
Pictures

YiHeng LHS-50CH Constant Temperature and Humidity ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | 10~85℃ |
| Temperature Resolution | 0.1℃ |
| Temperature fluctuation | ±1.0℃ |
| Humidity control range | 80~95%R.H |
| Humidity Deviation | ±3%R.H |
| Input power | 1450W |
| Environment temperature | 5~30℃ |
| Power | AC220V50HZ,LHS-100CB为:AV380V 50HZ |
| Interior size | 350*300*500mm |
| Dimensions | 720*620*725mm |
| Shelf (std.) | 2pcs |
YiHeng LHS-50CH Constant Temperature and Humidity Chamber Packing list
Constant Temperature and Humidity Chamber x1, instruction manual x1, packing list x1, certificate x1, warranty x1, warranty card x1, shelf x2, gauze x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 45939-2025
- ActiveIEC
- ActiveIEC
- ActiveASTM
- ActiveGB/T 2423.34-2024
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- 2058-2023
- ActiveQX/T 16-2020
- ActiveGB/T 38534-2020
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 41166-2021
- AbolishGB/T 2423.34-2005
- ActiveGB/T 8013.1-2018
- ActiveHG/T 5180-2017
- ActiveHG/T 5297-2018
- ActiveHG/T 5299-2018
- ActiveGB/T 2423.3-2016


LHS-50CH