JFL QHQ-A 750g pencil hardness meter
JFL QHQ-A pencil hardness meter load weight 750g, suitable for most soft and hard moderate film pencil Hardness test, QHQ pencil hardness meter contains horizontal pad and 13 pencils, is a coating Hardness Gauge.
JFL-
JINGKELIAN QHQ film Pencil Scratch Hardness Tester Determination of Paint Film Hardness by Pencil Hardness Grade of Plow Broken Paint Film
$ 313.00 -
QHQ-3084 Pencil Hardness Tester QHQ-3084 (500g/750g/1000g) JFL
$ 198.00 -
Pencil Hardness Tester TQC VF2378 A Hardness Tester that meets GB/T6739 pencil hardness testing standards
$ 1198.00 -
DUBAN DB20-LX-P Pencil Hardness Tester paints Hardness Gauge
$ 137.00 -
LANDTEK HT-6510P Pencil hardness Tester film Hardness detection
$ 131.00
Introduction
JFL pencil Hardness Tester is a pencil Hardness Tester designed and manufactured in strict accordance with GB/T5739-1996 for measuring the hardness of paint film. According to different test requirements, three weights of 500g, 750g and 1000g are produced, and the corresponding models are respectively For QHQ-A (500g), QHQ-A (750g), QHQ-A (1000g).
JFL QHQ-A (500g) / (750g) / (1000g) Pencil Hardness Tester is a mechanical structure design, which touches the surface to be tested through two wheels and three points of the pen core, and the pen core remains in contact with the test coating surface Make an angle of 45 degrees, and measure the hardness value of the paint film by pushing the Hardness Tester.
Note: This pencil Hardness Tester corresponds to a single weight. If you need a pencil Hardness Tester with three weights, please contact customer service.
real shot


Pencil Hardness Test Requirements
1. Test sample: Use smooth tinplate, the specification can be 120*50*(0.2-0.3) mm or other specifications, prepared according to GB1279-79 "General Preparation Method of Paint Film".
2. Pencil refill requirements: use a pencil sharpener to sharpen the pencil until the cylindrical lead core is exposed 5-6mm (do not loosen or scratch the refill), hold the refill so that it is 90 degrees from the "NO: 400" sandpaper surface ° included angle, and keep circling on the sandpaper to rub the end face of the refill until a lead lead with a flat end face and sharp edges is obtained (the edge must not be broken or notched).
The pencil should be rotated 180° after each use, or re-sharpened before use.
Test Methods
1) Put the QHQ-A (500g) / (750g) / (1000g) pencil Hardness Tester on a flat work surface, and place the pad on the lower part of the Hardness Tester.
2) Insert the pencil sharpened according to the requirements into the main hole of the pencil Hardness Tester, the edge of the pencil touches the workbench, and tighten the screw.
3) Put the QHQ-A (500g) / (750g) / (1000g) pencil Hardness Tester on the test board to be tested, and apply force at a speed of about 1mm per second (this force is about to break the edge of the lead core or plow damage to the coating) advance the pencil Hardness Tester.
4) Starting from the hardest pencil, plow five 3mm-long traces with each level of pencil until a pencil that does not plow the coating film is found. The hardness of this pencil represents the pencil hardness of the measured coating film.
JFL QHQ-A(750g) Pencil Hardness TesterSpecifications
| LIST | VALUE |
|---|---|
| Load | 750g |
| Applicable standard | GB/T 6739 |
| Standard pencil | Chinese pencils (13 pcs) |
JFL QHQ-A(750g) Pencil Hardness Tester Packing list
Host x1, horizontal pad x1, Chinese pencil x13
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the gloss meters that meet the GB/T9966 standard?
- What are the models of stone gloss meter? What is the difference?
- These gloss meters can be used in paper inspection, understand!
- How to choose the right model for Jinfulun JFL gloss meter?
- Jinfulun JFL-B60 Glossiness Meter instruction manual
- Study on uncertainty analysis of Moisture meter measurement results by drying method
- ActiveISO
- ActiveJB/T 3078-2015
- ActiveSJ 20910A-2018
- ActiveWJ 2669-2005
- ActiveJJF (石化)007-2018
- ActiveSY/T 4106-2016
- Active 002-2017
- ActiveHG/T 2006-2022
- ActiveGB/T 41899-2022
- ActiveGB/T 42541-2023
- ActiveGB/T 13448-2019
- ActiveGB/T 6739-2022
- ActiveHG/T 2006-2006
- ActiveGB/T 22374-2018
- ActiveGB/T 23997-2009
- ActiveHG/T 5370-2018
- ActiveHG/T 5367.1-2018
- ActiveHG/T 5187-2017
- ActiveHG/T 5180-2017
- ActiveHG/T 5175-2017


QHQ-A(750g)
A-3086
QHQ-A(500g)
QHQ-A(1000g)