Huitai LHS-500SC small Climate Chamber, with temperature limit alarm, temperature control 0~60 ℃/500L
With independent temperature limit alarm system, volume 500L, temperature control 0~60 ℃, humidity control 60~85% R.H, standard 3 load brackets, PID temperature control, fluorine-free refrigerant, international brand compressor.
HuiTai-
MODERNER HSX-250SC Constant Temperature and Humidity Chamber 10~45 ℃/250L
Login -
KESIONOTS KS-HW800A Programmable High Temperature Damping heat testing chamber 25~ 100 ℃/800L
$ 6973.00 -
KESIONOTS KS-HW1000L vertical humidity chamber -70 ℃/1000L
$ 10004.00 -
ZKHS DHS-010 Low Temperature Constant Moist Heat Box 0~100 ℃/1000L
$ 9522.00 -
Factory Direct NBC-150L-60/2 split constant temperature and humidity testing machine, high-low temperature heat and humidity alternating test
$ 7066.00
product description
Huitai LHS-500SC constant temperature and Humidity Chamber has an input power of 2000W, a volume of 500L, and a temperature control range of 0~60°C. It adopts large-screen LCD display, mirror-finished stainless steel liner, double-layer door structure, and good heat insulation effect. The temperature control of the constant temperature and Humidity Chamber is PID control, and the accuracy of temperature and humidity control fluctuates little.
Product use
Huitai LHS-500SC constant temperature and Humidity Chamber has a precise temperature and humidity control system. It provides various environmental simulation conditions for industrial research and biotechnology testing, so it can be widely used in aseptic conditions such as pharmaceuticals, textiles, and food processing. Tests, stability checks, and testing of raw material properties, product packaging, and product life of industrial products.
Features
1. Humanized design
●Large-screen LCD display, multi-group data display on one screen, menu-style operation interface, easy to understand and easy to operate. (standard configuration)
● Use 134 a, 406 a fluorine-free refrigerant, effective, energy-saving, and make the environment healthier!
● Mirror-finished stainless steel liner, semi-arc design at four corners for easy cleaning, and adjustable shelf spacing.
● Double-layer door structure is adopted, which has good heat insulation performance, and the temperature inside the box will not be affected when observing the situation inside the box.
● There is a test hole with a diameter of 25mm/50mm on the left side of the box, which is convenient for experimental operation and temperature measurement. (optional)
● Optional door observation window (except for optional, SC)
2. Quality Assurance
● International brand compressors are used, and the self-developed compressor cooling system can effectively prolong the service life of the compressor.
● Using JAKEL pipe flow circulation fan, coupled with uniquely designed air duct structure, creates a good air circulation system and effectively ensures the uniformity of temperature in the box.
● Adopt the humidity sensor of the international famous brand, and the self-designed built-in Water Tank electric heating tube humidification system can effectively guarantee the humidity deviation.
● PID control method, accurate temperature control and humidity control with little fluctuation, menu-style operation page, easy to understand and easy to operate.
● The program has 99 cycles, each cycle is divided into 30 segments, and each cycle is 99 hours and 99 minutes, which can meet almost all complicated experimental procedures.
3. Independent temperature limit alarm system (standard configuration)
● If the temperature exceeds the limit, the operation will be automatically interrupted, and the audible and visual alarm will prompt the operator. Ensure the safe operation of the experiment without accidents.
4. Convenient data processing (optional)
● With USB or RS485 interface, it can be connected to a printer or computer, and can record the changes of temperature parameters. (optional)
Optional
Intelligent program controller
Independent temperature limit controller
BOD special socket
Embedded printer
RS485 interface and special software
Door observation window (except SC)
Test hole 25mm/50mm
LHS series Climate Chamber parameter comparison table
project | LHS-100SC | LHS-150SC | LHS-250SC | LHS-500SC | LHS-100HC | LHS-150HC | LHS-250HC | LHS-500HC |
Voltage | AC220V 50HZ | |||||||
Temperature control range | 0~60℃ | -5℃~80℃ | ||||||
Constant temperature fluctuation | High temperature ±0.5°C Low temperature ±1.5°C | |||||||
temperature resolution | 0.1°C | |||||||
input power | 1100W | 1400W | 1950W | 2000W | 1100W | 1400W | 1950W | 2000W |
Inner tank size W×D×H(mm) | 450×380×590 | 480×400×780 | 580×500×850 | 800×700×900 | 450×380×590 | 480×400×780 | 580×500×850 | 800×700×900 |
Dimensions W×D×H(mm) | 575×605×1160 | 605×625×1350 | 705×725×1525 | 1000×1100×1860 | 575×605×1160 | 605×625×1350 | 705×725×1525 | 1000×1100×1860 |
Nominal volume | 100L | 150L | 250L | 500L | 100L | 150L | 250L | 500L |
Carrier (standard) | 2pcs | 3pcs | 2pcs | 3pcs | ||||
Timer Range | 1~9999min | |||||||
Note: The performance parameters are tested under no-load conditions, without strong magnetism and vibration: the ambient temperature is 20°C, and the ambient humidity is 50%RH.
1000L and other customized non-standard Incubators can be customized according to user needs.
HuiTai LHS-500SC + independent temperature limit alarm system Constant temperature and Humidity Chamber Specifications
| LIST | VALUE |
|---|---|
| Temperature range | 0~60℃ |
| temperature resolution | 0.1℃ |
| Temperature fluctuation | High temperature ± 0.5 ℃, low temperature ± 1.5 ℃ |
| Humidity control range | 60~85%R.H |
| Humidity Deviation | ±5~8%R.H |
| Input power | 2000W |
| Environment temperature | 20℃ |
| Power | AC220V 50HZ |
| Interior size | 800*700*900mm |
| Dimensions | 1000*1100*1860mm |
| Load carrier (std.) | 3pcs |
| Interior Volume | 500L |
| Timer | 1~9999min |
| Environment humidity | 50% RH |
| Temperature limit alarm | Independent temperature limit alarm system |
HuiTai LHS-500SC + independent temperature limit alarm system Constant temperature and Humidity Chamber Packing list
Host X1, fuse X2, rack X2, water tank X1, certificate X1, manual X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveIEC
- ActiveIEC
- ActiveASTM
- ActiveASTM
- ActiveGB/T 2423.34-2024
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveQX/T 16-2020
- Active 42091-2016
- ActiveGB/T 43489-2023
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- AbolishGB/T 2423.34-2005
- ActiveGB/T 2423.3-2016
- ActiveGB/T 1740-2007


LHS-500SC + independent temperature limit alarm system
LHS-500SC






