TASI /TASI TASI-601 K Dual channel digital thermometer Measurement range -200 ℃~ 1372 ℃
TASI TASI-601 digital thermometer, using K type dual channel thermocouple, is a liquid crystal digital display thermometer, TASI-601 Measuring temperature range of -200 ℃~ 1372 ℃, resolution of 0.1.
TASI-
BANTE TP-100P Temperature Probe 0~ 405 ℃ Suitable for MS300/400 Magnetic Stirrer
$ 102.00 -
Wasites WT100P-32 Multi-channel temperature Recorder Linear dispersion temperature Tester 32-channel Linear dispersion version
$ 788.00 -
HANNA HI151-00 high-precision temperature Tester -50.0~220.0 ℃ dairy products
$ 217.00 -
Liquid thermometer TQC TE0027 high-precision precision liquid thermometer
$ 291.00 -
Wasites WT200-48 Intelligent 48-way Temperature Logger Thermocouple Temperature Acquisition Linear dispersion
$ 1672.00
TASI-601 Digital Thermometer Product Features
◆ High precision thermometer, 0.1% basic accuracy
◆ T1, T2 dual input and T1-T2 function
◆ The large display screen is easy to read
◆ Thermocoupler line temperature compensation adjustment
◆ Impact-resistant protective sleeve
◆ °C and °F temperature unit switching function
◆ Automatic shift 0.1°C/1°C
◆ Automatic shutdown function
◆ Backlit display function
◆ Maximum, minimum, average, relative reading and reading value retention functions
◆ Wide range of measurement, suitable for various measurement applications
Structural function diagram
1. Power switch button
2. "°C/°F" button: unit switch key
3. "☀" key: backlight function key
4. "ADJ" key: adjust the thermocouple offset value
5. "▲/REL" button: turn on the relative mode of measured values
6. "▼/HOLD" button: enter the measurement value lock mode
7. "APO" key: APO function
8. "MAX/MIN" button: enter MAX and MIN recording mode
9. "ENTER" key: confirm key
10. T1 input of "T1" channel

A- Temperature measurement results;C - Low Voltage symbol;D-Hot spot element input type
E - Auto Shutdown Symbol;F - Record Indicator Symbol;G - maximum value indication symbol;
H - Minimum indicator, I - Mean indicator, J - Relative indicator;
K - Readings retain the indicator, L - Celsius temperature unit symbol, and M - Fahrenheit temperature unit symbol
Product display diagram






Safety instructions for the operation of dual-channel digital thermometers
1. Before using the TASI-601 digital thermometer, please read the operation safety instructions and instructions.
2. When the surface measurement Voltage exceeds 24V DC/AC, the measurement needs to be stopped to avoid clicking.
3. Do not use in the microwave oven to avoid burning.
4. Before replacing the battery, be sure to unplug the temperature test wire from the thermometer to maintain safety.
Precautions for the use of digital thermometers
1. If the battery is insufficient, please replace the battery to maintain the accuracy of the test.
2. When the thermometer is not in use for a long time, please remove the battery from the TASI-601 thermometer and avoid storing it in a high temperature place. 3. Regularly use a soft damp cloth dipped in neutral detergent to gently wipe the shell, not use an abrasive cloth or solvent with soluble ability to wipe.
3. Repeatedly bending the thermocouple line will break it. Avoiding bending thermocouple wires, especially near corners, can extend the life of thermocouple wires.
Place of use
Greenhouses, offices, laboratories, environmental research, climate monitoring, art galleries, department stores, factories.
TASI TASI-601 Thermocouple ThermometerSpecifications
| LIST | VALUE |
|---|---|
| Temperature Measurement Range | -200~1372℃ |
| Number of channels | 2 channel |
| Accuracy | +/- (0.1% rdg + 1 ℃) at -60 ℃~ 137 < br > +/- ( 0.1% rdg + 2 ℃) at -60 ℃~ 200 ℃ < br > +/- ( 0.1% rdg + 2 ° F) at -76 ° F~ 1999 ° F < br > +/- ( 0.1% rdg + 4 ° F) at -76 ° F~ -328 ° F |
| Resolution | 0.1 |
| Accuracy test environment | 23 ℃ +/- 5 ℃, Relative Humidity < 75% R.H. |
| Display | 3 ½ digit LCD display, maximum 1999 readings |
| Low battery Voltage display | When the battery Voltage is lower than the operating Voltage ,“+ - ” display |
| Sampling rate | 2.5 times/s |
| Power Supply | Four 1.5V AA batteries |
| Environmental temperature | 0~50℃ |
| Storage environment | -20~60℃,0~70%R.H. |
| Dimensions | 160*83*38mm |
| Weight | Approximately 235 grams |
| Standard Accessories | Manual, Thermocouple Cable, Battery |
| Allowable Relative Humidity | <80%R.H. |
TASI TASI-601 Thermocouple Thermometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Thermocouple thermometer purchase points
- Linear dispersion test in high temperature heat treatment
- Thermocouple measurement principle and characteristics
- Introduction to the calibration method of thermocouple
- Preparation process of electron beam curing Wooden furniture coatings
- Thermal resistance measurement principle and type introduction


TASI-601