MODERNER XTH-030C High and Low Temperature Humidity Cyclic Chamber -70 ℃/306L
Ultra-low temperature -70 ℃~ 150 ℃, content volume 306L, equilibrate Conditioning (BTC) mode, imported fully enclosed compressor, used for high-low temperature, high-low temperature gradual change, constant heat and humidity and alternating humidity cabinet test.
Moderner-
Lugong ST-408LA Humidity Chamber constant environment temperature and humidity tolerance test -20 ℃~ + 150 ℃
$ 4159.00 -
CHINA NBC-225L-20 programmable rapid temperature change humidity cabinet test -20 ℃~ 150 ℃/225L
$ 2989.00 -
CHINA NBC-408L-20 Programmable Reliability Environmental Test Chamber Paint Panel -20 ℃/408L
$ 3610.00 -
HZAOC hzaoc GDJS-225A Temperature Humidity Cyclic Chamber -20~150 ℃/225L
$ 7486.00 -
Haiyoda Program Constant Temperature and Humidity Test Chamber, Humid Hot Box QT-E702-225B40 -40 ℃/225L
$ 2791.00
Introduction
This equipment simulates high-low temperature and high-low temperature cycle environments. It is suitable for performing high temperature, low temperature, high humidity, low humidity, high-low temperature humidity alternation, and temperature on electrical and electronic products, lighting products, parts, materials, and Chinese electronic components. The performance and storage adaptability under cyclic changing conditions can also be used to check the sample's ability to withstand certain corrosion (non-monoxidized acids and alkalis).
Features
1. Used for high-low temperature, high-low temperature gradient, constant damp and heat and alternating damp and heat tests of industrial products and parts;
2. The refrigeration circuit can realize automatic opening and closing of the compressor and automatic adjustment of output power;
3. In addition to wet and dry bulbs, humidity sensors can also be used for humidity control;
4. Using balanced temperature/humidity adjustment method, the temperature/humidity control has high precision and fast stabilization speed;
5. The temperature control instrument is easy to operate and has a friendly interface;
6. Standard test curve USB export port and LAN communication interface.
fulfill the standard
GB/T10586-2006 Technical conditions for heat and Humidity Test Chamber
GB/T10589-1989 Technical conditions for low Temperature Test Chamber
GB/T11158-2006 High Temperature Test Chamber technical conditions
GB/T2423.1-2001 (IEC68-2-1) Test A: Low temperature test method
GB/T2423.2-2001 (IEC68-2-2) Test B: High temperature test method
GB/T2423.3-2006 (IEC68-2-3) Test Ca: Constant damp heat test method
GB/T2423.4-1993 (IEC68-2-30) Test Db: Alternating damp heat test method
GB/T2423.1-2008 Environmental testing of electrical and electronic products Part 2: Test method test A. Low temperature (IEC60068-2-1:2007)
GB/T2423.2-2008 Environmental testing for electrical and electronic products Part 2: Test method test A. Low temperature (IEC60068-2-1:2007)
GBT10592-2008 High-low Temperature Test Chamber technical conditions (temperature alternating)
GB/T2423.1-2008 Environmental testing of electrical and electronic products Part 2: Test method test A. Low temperature (IEC60068-2-1:2007)
GB/T2423.2-2008 Environmental testing for electrical and electronic products Part 2: Test method test A. Low temperature (IEC60068-2-1:2007)
GB/T2423.3-2006 Electrical and electronic product environmental testing Part 2: Test method test Cab constant temperature test (IEC60068-2-78:2001)
GB/T2423.59-200 Electrical and electronic product environmental testing Part 2: Test method test Z/ABMFh temperature, humidity and vibration three comprehensive
GB/T2423.4-2008 Electrical and electronic products environmental testing Part 2: Test method test Db alternating warm 12h+12h cycle (IEC60068-2-30:2005)
GB/T2423.9-2001 Environmental testing of electrical and electronic products Part 2: Test method Test Cb equipment with constant temperature (IEC60068-2-56)
GB/Y2423.22-2002 Electrical and electronic products environmental testing Part 2: Test method test N temperature change (IEC60068-2-14)
GJB150.3 (MIL-STD-810D) High Temperature Test Method
GJB150.4 (MIL-STD-810D) Low temperature test method
GJB150.9 (MIL-STD-810D) Damp heat test method
Moderner XTH-030C High-low temperature alternating (heat and humidity) Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Power | AC220V 50Hz |
| Maximum current | 15A |
| Maximum Power | 9.1KW |
| Temperature control method | Equilibrating Conditioning (BTC) |
| Temperature range | -70~150℃ |
| Humidity control range | 20~98%R.H |
| Temperature Fluctuation | ≤±0.5℃ |
| Temperature Uniformity | ≤2℃ |
| Temperature deviation | ≤±2℃/+2,-3%RH |
| Heating rate | -70~+100℃≤60min;-70~+150℃≤75min |
| Cooling rate | ﹢20~-70℃≤80mins |
| Enclosure Material | Cold rolled steel plate |
| Chamber material | SUS304 2B stainless steel plate |
| Insulation material | Rigid Polyurethane Foam (+ Ultrafine Glass Cotton) |
| refrigeration method | Single compression refrigeration (air-cooled) |
| Refrigeration system | Imported fully enclosed compressor |
| Compressor Capacity | 3+3HP |
| Condenser | Heat sink type chilling down (double as dehumidifier) |
| Water supply method | Electromagnetic pump |
| Water tank Capacity | 20L |
| Heating system | Nickel chromium wire heating |
| blower | centrifugal fan |
| Temperature transducer | High-precision platinum resistor (PT100) |
| Controller | UMC1200 programmable touch LCD Controller with remote monitoring and debugging software package |
| Interior Volume | 306L |
| Interior size | 600*850*600mm |
| Dimensions | 1060*1990*1040mm |
| Weight | 450kg |
Moderner XTH-030C High-low temperature alternating (heat and humidity) Test Chamber Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


XTH-030C