CHINA Three-Chamber high-low temperature impact test box NBC-LRCJ-80L -60 ℃
Stainless steel panel, volume 80L, programmable, touch screen operation, control accuracy +/- 0.2 ℃, stainless steel panel, Temperature uniformity +/- 2 ℃, using imported refrigeration compressor, temperature control -40 ℃~ + 150 ℃.
HuiTai-
KESIONOTS Three Box Thermal Shock Tester KS-OTS-LR225LB Low Temperature -55 ℃/225L
$ 35049.00 -
ZKHS WDCJ-340B High and low temperature impact test box Thermal Shock box -40 ℃~ 150 ℃
$ 28053.00 -
Aipei 3AP-CJ-150A Three-Chamber Thermal Shock Air-Cooled -40 ℃
$ 21057.00 -
ZKHS WDCJ-340A High and low temperature impact test chamber Thermal Shock test chamber -20 ℃~ 150 ℃
$ 24400.00 -
KESIONOTS high and low temperature impact test box KS-OTS-LR225LA low temperature -45 ℃/225L
$ 36759.00
Overview
This series of thermal shock testing machine is mainly used to test the resistance of materials to extremely high or low temperatures, which is similar to the situation of discontinuous high or low temperatures, and the thermal shock test can make various items complete the test in the shortest time. The changes or physical injuries caused by thermal shocks are caused by changes in thermal expansion and contraction or other physical values, and all kinds of products can be fully trusted by using the PID system. The effects of thermal shock include electrochemical changes caused by cracking or breaking layers and displacement of the finished product, and the full digital element automatic control of the PID system will make it easy for you to operate.
Hot and cold shock testThe purpose of the machine inspection
Thermal shock testing machine is widely used in electronic and electrical components, automation parts, communication components, auto parts, metals, chemical materials, plastics and other industries, national defense industry, aerospace, military industry, BGA, PCB base wrench, electronic chip IC, semiconductor ceramic and polymer materials physical changes, testing the repeated tensile force of the material to high-low temperature and the chemical change or physical damage of the product in thermal expansion and contraction, can confirm the quality of the product. From precision ICs to heavy machinery components, it can be used as the basis or reference for the improvement of its products.
Enforce and meet standards
1. GB/T2423.1-2001 low temperature test method;
2、GB/T2423.2-2001;
3. GB/T2423.22-1989 temperature change test N;
4. National military standard GJB150.3-86;
5. National military standard GJB150.4-86;
6. National military standard GJB150.5-86;
7. GJB150.5-86 temperature shock test;
8. GJB360.7-87 temperature shock test;
9. GJB367.2-87 405 temperature shock test;
10. SJ/T10187-91Y73 series temperature change Test Chamber - one box;
11. SJ/T10186-91Y73 series temperature change Test Chamber - two-chamber type;
12. Meet the standard IEC68-2-14_ test method N_ temperature change;
13. GB/T 2424.13-2002 Test Method Temperature Change Test Guidelines;
14. GB/T 2423.22-2002 temperature change;
15 QC/T17-92 General rules for weather resistance test of auto parts;
16. EIA 364-32 Environmental Impact Assessment of Electrical Connectors and Receptacles for Thermal Shock (Temperature Cycling) Test Procedures.
Refrigeration system
1. Operating Principle:Three-Chamber type, product static test mode
2. Condensation method:Air-cooled and power-saving ultra-low temperature refrigeration system (air-cooled heat dissipation method)
3. Refrigeration compressor:French Taikang high-horsepower mechanical compressor
4. Evaporator:Fin heat exchanger (doubles as a dehumidifier)
5. Throttling device:Electronic expansion valves
6. Evaporative condenser:Brazed plate heat exchanger
7. Chiller control mode
The control system automatically adjusts the chiller according to the test conditions for better operation
Energy-saving conditions
Compressor return air cooling circuit
Energy regulation loops
8. Digital display of refrigeration system Operating Conditions
Evaporative pressure regulating valve
The controller digitally displays the high-low pressure pressure, exhaust temperature and compressor operating current of the refrigeration system
9. Refrigerant:R404a/R23 (both ozone depletion index 0)
10. Others: The main components are all international good brand products
Heating system
Heater: nickel-chromium alloy heating wire heater;Heater control mode: Constant periodic pulse width adjustment without contact, SSR (Solid State Relay)
Electrical control system
Controller model: Korean TIMI8226
The product uses computer technology, excellent PID control method to measure and control the ambient temperature, and can be used with thermal shock test equipment.
★ The display and control interface is intuitive and clear, and the touch selection menu is easy to use, and the performance is stable and reliable.
★ Effective, flexible program control, to bring users stable performance, flexible control, cost-effective high-end products.
★Program editing: There are three types of programs, namely 2ZONE, 3ZONE, and STEP
Category 1 is 2ZONE, which can edit 120 programs, each with only 2 segments
Category 2 is 3ZONE, which can edit 120 programs, each with only 3 segments
Category 3 is STEP, which can edit 120 programs with a maximum of 20 segments per program
Range: The program can be linked (the serial number of the linked program can be selected)
Temperature: Adjusted according to the temperature operating range of the device (upper limit +5°C, lower limit -5°C)
Display Resolution:Temperature: 0.01°C;Time: 0.01min
Input:thermocouple
Communication function (optional):RS-232 converter
Curve recording function:RAM with battery protection to save the device's setpoint, sample value and time of sampling time, with a maximum recording time of 350 days (when the sampling period is 1.5 minutes)
1) Door: Hinged door, door hinge on the left side of the box (when facing the front of the box)Door distribution heating (automatic adjustment) Anti-frost, anti-condensation insulating glass observation window(W210×H320mm) a;
The door frame is equipped with electric heating (automatic adjustment) anti-frost and anti-condensation device;Interior light on the door (effective long-life LED light source)
2) Control Panel: Controller Display,Operation button, over-temperature protection setting device
3) Mechanical room machine:Included in the machinery roomRefrigeration units, drainage devices, fans, distribution control cabinets
4) Power distribution control cabinet:Cooling fan,buzzerSwitchboards
Safety protection device
systemCold system
Compressor high-low pressure overpressure protection
Compressor motor overheating protection
Compressor motor overcurrent protection
Frozen oil pressure liquid mirror
Refrigerant high-low pressure gauge
Test chambers
Adjustable over-temperature protection
Test space temperature fuse filament
The air conditioning channel is overheated at the limit
The fan motor is overheated
Air pressure balance device inside and outside the box
When the box door is opened (in operation), it prompts an alarm
Other configurations
1) Power Cable:1 x 5-core cable (4-core cable + protective grounding wire) (6 m long)
2) Specimen power control terminal
Total power leakage circuit breaker
Relay contact control, within AC380V, 20A (when normal operation, the contact is closed;
When the equipment is shut down or malfunctioning, the contacts are disconnected)
It is strongly recommended that users use the control terminal to control the power on and off of the test sample to ensure that
In the event of a machine failure or shutdown, the circuits connected to the test specimen are reliably cut off
3) Materials: Provide Chinese version of user manuals and technical materials
4) Transportation: The main structure of the Test Chamber is integral
5) Conditions of Use:The user warrants the following conditions
6)venue
The floor is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust
There are no sources of strong electromagnetic radiation in the vicinity
Drain floor drain near the equipment (within 2 meters from the refrigeration unit)
Site ground load capacity: not less than 800kg/m2 Leave appropriate maintenance space around the equipment
7) Environmental conditions
Temperature: +5°C~+35°C
Relative Humidity: ≤ 85%RH
Air pressure: 86 kPa~106kPa
8) Power supply
AC (380±10)V (50±0.5)Hz three-phase four-wire + PGD
The grounding resistance of the protective ground wire is less than 4Ω, and the power supply is supplied by TN-S mode or TT mode
The user is required to configure the equipment with an air or power switch of the appropriate capacity at the installation site, andThis switch needs to be stand-alone and dedicated for use by this device
9) Power Capacity:21kw
10) Requirements for the storage environment
When the equipment is not working, the temperature of the environment should be kept within 0~+45°C (no freezing).
When the ambient temperature is lower than 0°C, the water remaining in the equipment should be discharged to avoid pipes
The water inside freezes and swells the pipes
HuiTai NBC-LRCJ-80L-60 Three-Chamber Thermal Shock Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Inner Volume | 80L |
| Temperature and Humidity Control Instrument | Programmable TEMP8226S imported from Korea, touch screen input, different temperature points can be arbitrarily set according to customer requirements |
| Box structure | This equipment is divided into: test area, low temperature cold storage area, high temperature heat storage area |
| Liner size | 500*400*400mm |
| Dimensions | 1500*1900*1500mm |
| Temperature Impact Range | -60 ℃~ + 150 ℃ (programmable to set arbitrarily) |
| Temperature range of regenerator | 0 ℃~ + 170 ℃ (programmable to set arbitrarily) |
| Temperature range of storage tank | 0 ℃~ -60 ℃ (programmable to set arbitrarily) |
| Controller control Accuracy | ±0.2℃ |
| Temperature Impact Rate | Complete in 5 minutes |
| Enclosure Material | SUS #304 stainless steel plate |
| Liner material | Heat-resistant and cold-resistant stainless steel plate, first-class light panel |
| Insulation material | High Density Glass Cotton and High Strength PU Foam Insulation Material |
| box uniformity | ±2℃ |
| Air supply circulation system | Japanese multi-wing centrifugal Circulating Fan, Japanese motor whole group |
| Heating system | U-shaped fin type 304 #seamless steel high-speed heating electric heater |
| Refrigeration system | France taikang compressor |
| Refrigeration accessories | Table bending center force evaporator, Mar fan, etc |
| Refrigeration system | air-cooled |
| Test box load | 20KG |
| Protection device | Compressor overheating, overtemperature, overload, high Voltage, low pressure, oil pressure, overcurrent, lack of phase, power failure standby and other alarm warnings |
| Power supply Voltage | AC380V 50~60Hz 10~15KW |
| meet the standard | GB2423 [1] .02 High temperature test method, GB2423 [1] .01 Low temperature test method |
| Control mode | 5.7-Inch color touchscreen |
| Control mode | program |
| Sensor type | PT100 Sensors Input |
| output method | PID control output; (4-20mA) analog circuit output; 8-way switching signal auxiliary input; (basic configuration of 10 relays, optional 20 relays) |
| Measurement range | -200.00 ℃ --300.00 ℃, error +/- 0.2 ℃ |
| program editing | There are three types of programs, namely 2ZONE, 3ZONE, and STEP. |
| language | Chinese and English can be switched |
| Controller Power Supply | Rated Voltage: 85-265V AC, 50/60Hz, lithium battery for at least 10 years, withstand Voltage 2000V AC/1 minute |
| Controller external Dimensions | 184*144*94mm |
| Controller mounting opening size | 173 × 133 (mm) (L × W) |
| TFT resolution | 640 × 64k color |
HuiTai NBC-LRCJ-80L-60 Three-Chamber Thermal Shock Test Chamber Packing list
machine x1, manual x1, certificate of conformity
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Precision heat & cold shock testing device
- Principle, structure, function and application of high-low temperature impact Test Chamber
- Explore the principle, application and selection points of two-box high-low temperature impact test box
- The principle, application and selection of mobile phone data line temperature impact test box
- ActiveGB/T 7991.3-2021
- ActiveGB/T 2423.22-2012
- ActiveGJB 150.5a-2009
- ActiveGJB 150.5-1986
- ActiveGB/T 2423.22-2002


NBC-LRCJ-80L-60