Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Thermal Shock Test Chamber> HuiTai> HuiTai NBC-LRCJ-80L-60 Three-Chamber Thermal Shock Test Chamber
      HuiTai NBC-LRCJ-80L-60 Three-Chamber Thermal Shock Test Chamber

      CHINA Three-Chamber high-low temperature impact test box NBC-LRCJ-80L -60 ℃

      Stainless steel panel, volume 80L, programmable, touch screen operation, control accuracy +/- 0.2 ℃, stainless steel panel, Temperature uniformity +/- 2 ℃, using imported refrigeration compressor, temperature control -40 ℃~ + 150 ℃.

      Brand
      SKU: NB041288
      China HuiTai
      VS
      HuiTaiLOGO

      HuiTai

      Information
      Genuinegoods
      • HuiTai NBC-LRCJ-80L-60 Three-Chamber Thermal Shock Test ChamberOverview

      • Specifications
      • Comments
      • FAQs
      NBC-LRCJ-80L-60
      Three-Chamber Thermal Shock Test Chamber
      • CHINA Three-Chamber high-low temperature impact test box NBC-LRCJ-80L -60 ℃
      Stainless steel panel, volume 80L, programmable, touch screen operation, control accuracy +/- 0.2 ℃, stainless steel panel, Temperature uniformity +/- 2 ℃, using imported refrigeration compressor, temperature control -40 ℃~ + 150 ℃.

      Overview  

      This series of thermal shock testing machine is mainly used to test the resistance of materials to extremely high or low temperatures, which is similar to the situation of discontinuous high or low temperatures, and the thermal shock test can make various items complete the test in the shortest time. The changes or physical injuries caused by thermal shocks are caused by changes in thermal expansion and contraction or other physical values, and all kinds of products can be fully trusted by using the PID system. The effects of thermal shock include electrochemical changes caused by cracking or breaking layers and displacement of the finished product, and the full digital element automatic control of the PID system will make it easy for you to operate.

      Hot and cold shock testThe purpose of the machine inspection

      Thermal shock testing machine is widely used in electronic and electrical components, automation parts, communication components, auto parts, metals, chemical materials, plastics and other industries, national defense industry, aerospace, military industry, BGA, PCB base wrench, electronic chip IC, semiconductor ceramic and polymer materials physical changes, testing the repeated tensile force of the material to high-low temperature and the chemical change or physical damage of the product in thermal expansion and contraction, can confirm the quality of the product. From precision ICs to heavy machinery components, it can be used as the basis or reference for the improvement of its products.

      Enforce and meet standards

      1. GB/T2423.1-2001 low temperature test method;

      2、GB/T2423.2-2001;

      3. GB/T2423.22-1989 temperature change test N;

      4. National military standard GJB150.3-86;

      5. National military standard GJB150.4-86;

      6. National military standard GJB150.5-86;

      7. GJB150.5-86 temperature shock test;

      8. GJB360.7-87 temperature shock test;

      9. GJB367.2-87 405 temperature shock test;

      10. SJ/T10187-91Y73 series temperature change Test Chamber - one box;

      11. SJ/T10186-91Y73 series temperature change Test Chamber - two-chamber type;

      12. Meet the standard IEC68-2-14_ test method N_ temperature change;

      13. GB/T 2424.13-2002 Test Method Temperature Change Test Guidelines;

      14. GB/T 2423.22-2002 temperature change;

      15 QC/T17-92 General rules for weather resistance test of auto parts;

      16. EIA 364-32 Environmental Impact Assessment of Electrical Connectors and Receptacles for Thermal Shock (Temperature Cycling) Test Procedures.

      Refrigeration system

      1. Operating PrincipleThree-Chamber type, product static test mode

      2. Condensation methodAir-cooled and power-saving ultra-low temperature refrigeration system (air-cooled heat dissipation method)

      3. Refrigeration compressorFrench Taikang high-horsepower mechanical compressor

      4. EvaporatorFin heat exchanger (doubles as a dehumidifier)

      5. Throttling deviceElectronic expansion valves

      6. Evaporative condenserBrazed plate heat exchanger

      7. Chiller control mode

      • The control system automatically adjusts the chiller according to the test conditions for better operation

      • Energy-saving conditions

      • Compressor return air cooling circuit

      • Energy regulation loops

      8. Digital display of refrigeration system Operating Conditions

      • Evaporative pressure regulating valve

      • The controller digitally displays the high-low pressure pressure, exhaust temperature and compressor operating current of the refrigeration system


      9. Refrigerant:R404a/R23 (both ozone depletion index 0)

      10. Others: The main components are all international good brand products

      Heating system

      Heater: nickel-chromium alloy heating wire heater;Heater control mode: Constant periodic pulse width adjustment without contact, SSR (Solid State Relay)

      Electrical control system

      Controller model: Korean TIMI8226

      The product uses computer technology, excellent PID control method to measure and control the ambient temperature, and can be used with thermal shock test equipment.

      ★ The display and control interface is intuitive and clear, and the touch selection menu is easy to use, and the performance is stable and reliable.

      ★ Effective, flexible program control, to bring users stable performance, flexible control, cost-effective high-end products.

      Program editing: There are three types of programs, namely 2ZONE, 3ZONE, and STEP

      • Category 1 is 2ZONE, which can edit 120 programs, each with only 2 segments

      • Category 2 is 3ZONE, which can edit 120 programs, each with only 3 segments

      • Category 3 is STEP, which can edit 120 programs with a maximum of 20 segments per program

      Range: The program can be linked (the serial number of the linked program can be selected)

      Temperature: Adjusted according to the temperature operating range of the device (upper limit +5°C, lower limit -5°C)

      Display Resolution:Temperature: 0.01°C;Time: 0.01min

      Input:thermocouple

      Communication function (optional):RS-232 converter

      Curve recording function:RAM with battery protection to save the device's setpoint, sample value and time of sampling time, with a maximum recording time of 350 days (when the sampling period is 1.5 minutes)

      1) Door: Hinged door, door hinge on the left side of the box (when facing the front of the box)Door distribution heating (automatic adjustment) Anti-frost, anti-condensation insulating glass observation window(W210×H320mm) a;

      The door frame is equipped with electric heating (automatic adjustment) anti-frost and anti-condensation device;Interior light on the door (effective long-life LED light source)

      2) Control Panel: Controller Display,Operation button, over-temperature protection setting device

      3) Mechanical room machine:Included in the machinery roomRefrigeration units, drainage devices, fans, distribution control cabinets

      4) Power distribution control cabinetCooling fan,buzzerSwitchboards

      Safety protection device

      systemCold system

      • Compressor high-low pressure overpressure protection

      • Compressor motor overheating protection

      • Compressor motor overcurrent protection

      • Frozen oil pressure liquid mirror

      • Refrigerant high-low pressure gauge

      Test chambers

      • Adjustable over-temperature protection

      • Test space temperature fuse filament

      • The air conditioning channel is overheated at the limit

      • The fan motor is overheated

      • Air pressure balance device inside and outside the box

      • When the box door is opened (in operation), it prompts an alarm

      Other configurations

      1) Power Cable:1 x 5-core cable (4-core cable + protective grounding wire) (6 m long)

      2) Specimen power control terminal

      • Total power leakage circuit breaker

      • Relay contact control, within AC380V, 20A (when normal operation, the contact is closed;

      • When the equipment is shut down or malfunctioning, the contacts are disconnected)

      • It is strongly recommended that users use the control terminal to control the power on and off of the test sample to ensure that

      • In the event of a machine failure or shutdown, the circuits connected to the test specimen are reliably cut off

      3) Materials: Provide Chinese version of user manuals and technical materials

      4) Transportation: The main structure of the Test Chamber is integral

      5) Conditions of UseThe user warrants the following conditions

      6)venue

      • The floor is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust

      • There are no sources of strong electromagnetic radiation in the vicinity

      • Drain floor drain near the equipment (within 2 meters from the refrigeration unit)

      • Site ground load capacity: not less than 800kg/m2 Leave appropriate maintenance space around the equipment

      7) Environmental conditions

      • Temperature: +5°C~+35°C

      • Relative Humidity: ≤ 85%RH

      • Air pressure: 86 kPa~106kPa

      8) Power supply

      • AC (380±10)V (50±0.5)Hz three-phase four-wire + PGD

      • The grounding resistance of the protective ground wire is less than 4Ω, and the power supply is supplied by TN-S mode or TT mode

      • The user is required to configure the equipment with an air or power switch of the appropriate capacity at the installation site, andThis switch needs to be stand-alone and dedicated for use by this device

      9) Power Capacity:21kw

      10) Requirements for the storage environment

      • When the equipment is not working, the temperature of the environment should be kept within 0~+45°C (no freezing).

      • When the ambient temperature is lower than 0°C, the water remaining in the equipment should be discharged to avoid pipes

      • The water inside freezes and swells the pipes

      VS

      HuiTai NBC-LRCJ-80L-60 Three-Chamber Thermal Shock Test ChamberSpecifications

      LIST VALUE
      Inner Volume 80L
      Temperature and Humidity Control Instrument Programmable TEMP8226S imported from Korea, touch screen input, different temperature points can be arbitrarily set according to customer requirements
      Box structure This equipment is divided into: test area, low temperature cold storage area, high temperature heat storage area
      Liner size 500*400*400mm
      Dimensions 1500*1900*1500mm
      Temperature Impact Range -60 ℃~ + 150 ℃ (programmable to set arbitrarily)
      Temperature range of regenerator 0 ℃~ + 170 ℃ (programmable to set arbitrarily)
      Temperature range of storage tank 0 ℃~ -60 ℃ (programmable to set arbitrarily)
      Controller control Accuracy ±0.2℃
      Temperature Impact Rate Complete in 5 minutes
      Enclosure Material SUS #304 stainless steel plate
      Liner material Heat-resistant and cold-resistant stainless steel plate, first-class light panel
      Insulation material High Density Glass Cotton and High Strength PU Foam Insulation Material
      box uniformity ±2℃
      Air supply circulation system Japanese multi-wing centrifugal Circulating Fan, Japanese motor whole group
      Heating system U-shaped fin type 304 #seamless steel high-speed heating electric heater
      Refrigeration system France taikang compressor
      Refrigeration accessories Table bending center force evaporator, Mar fan, etc
      Refrigeration system air-cooled
      Test box load 20KG
      Protection device Compressor overheating, overtemperature, overload, high Voltage, low pressure, oil pressure, overcurrent, lack of phase, power failure standby and other alarm warnings
      Power supply Voltage AC380V 50~60Hz 10~15KW
      meet the standard GB2423 [1] .02 High temperature test method, GB2423 [1] .01 Low temperature test method
      Control mode 5.7-Inch color touchscreen
      Control mode program
      Sensor type PT100 Sensors Input
      output method PID control output; (4-20mA) analog circuit output; 8-way switching signal auxiliary input; (basic configuration of 10 relays, optional 20 relays)
      Measurement range -200.00 ℃ --300.00 ℃, error +/- 0.2 ℃
      program editing There are three types of programs, namely 2ZONE, 3ZONE, and STEP.
      language Chinese and English can be switched
      Controller Power Supply Rated Voltage: 85-265V AC, 50/60Hz, lithium battery for at least 10 years, withstand Voltage 2000V AC/1 minute
      Controller external Dimensions 184*144*94mm
      Controller mounting opening size 173 × 133 (mm) (L × W)
      TFT resolution 640 × 64k color

      HuiTai NBC-LRCJ-80L-60 Three-Chamber Thermal Shock Test Chamber Packing list

      machine x1, manual x1, certificate of conformity

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      HuiTai
      CHINA Three-Chamber high-low temperature impact test box NBC-LRCJ-80L -60 ℃
      Service
      Focus on online sales of Lab Testing Instruments