Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Humidity tTest Chamber> HUDA> HUDA QT-E702-408B70 Programmable Humidity Chamber

      HUDA Aluminum profile coating Constant Temperature and Humidity Chamber QT-E702-408B70 -70 ℃/408L

      304 stainless steel panel, volume 408L, PID temperature control -70 ℃~ 150 ℃, programmable control, mechanical binary refrigeration mode, French Taikang fully enclosed compressor, independent high temperature control.

      Brand
      SKU: NB041363
      China HUDA
      VS
      Genuinegoods
      • HUDA QT-E702-408B70 Programmable Humidity ChamberOverview

      • Specifications
      • Comments
      • FAQs
      QT-E702-408B70
      Programmable Humidity Chamber
      • HUDA Aluminum profile coating Constant Temperature and Humidity Chamber QT-E702-408B70 -70 ℃/408L
      • HUDA Aluminum profile coating Constant Temperature and Humidity Chamber QT-E702-408B70 -70 ℃/408L Figure 1
      • HUDA Aluminum profile coating Constant Temperature and Humidity Chamber QT-E702-408B70 -70 ℃/408L Figure 2
      304 stainless steel panel, volume 408L, PID temperature control -70 ℃~ 150 ℃, programmable control, mechanical binary refrigeration mode, French Taikang fully enclosed compressor, independent high temperature control.

      Introduction

      This series of constant temperature and humidity testing machines are mainly used to simulate the harsh high-low temperatures that electronic instruments, new materials, electricians, vehicles, metals, electronic products, aerospace materials, etc. may encounter during transportation, storage, and use. Or in a hot and humid environment; or in an environment of alternating high temperature, low temperature, and humid heat, test the resistance of materials, accessories, or equipment to high temperature, cold resistance, heat and humidity, and possible damage and shortened lifespan.

      Hiyoda QT-E702-408B70 programmable constant temperature and Humidity Test Chamber details Figure 1

      Hiyoda QT-E702-408B70 programmable constant temperature and Humidity Test Chamber details Figure 2

      Hiyoda QT-E702-408B70 programmable constant temperature and Humidity Test Chamber details Figure 3

      Hiyoda QT-E702-408B70 programmable constant temperature and Humidity Test Chamber details Figure 4

      Hiyoda QT-E702-408B70 programmable constant temperature and Humidity Test Chamber details Figure 5

      Features

      (1) Box structure:

      1. Inner box material: Made of SUS304# (1.0mm thick) stainless steel plate, which has the advantages of acid resistance, corrosion resistance, and easy cleaning.

      2. Enclosure Material: SUS304# (1.0mm thick) stainless steel plate.

      3. Door handle: It adopts non-reaction and explosion-proof door handle, which is easy to operate, safe and reliable.

      4. Insulation system: Ultra-fine glass fiber is used to fill the insulation area, and the connection parts of the inner and outer boxes are made of non-metallic high-low temperature resistant materials to effectively reduce temperature conduction; the door seal is made of refined silicone rubber, so there is no aging under high-low temperature conditions. and hardening phenomenon, the sealing is more reliable; the humidification method adopts isolated humidification.

      5. Moving and positioning device: High-quality fixed PU movable wheels are installed at the bottom of the machine, which can easily move the machine to a designated position and then fix the casters.

      6. Sample rack: It is made of SUS304# stainless steel punched and bent into a mesh shape. It is easy to use. The spacing between the material racks is adjustable. There are two pieces in the standard configuration. The samples are evenly distributed according to the load-bearing ≧20kg.

      7. Test hole: Open a Φ50mm test hole, and attach corresponding thermal insulation accessories and special sealing plugs

      8. Observation window: It adopts double-layer vacuum-strengthened glass, and the inner glued conductive film is heated and defrosted to clearly observe the test process.

      (2) Refrigeration system:

      1. The refrigeration unit uses French Taikang compressors and American DuPont environmentally friendly refrigerant (R404a). It adopts a binary low-temperature circuit system design to facilitate the use of different compressors in different temperature ranges to increase equipment.

      2. Temperature and humidity control adopts PID + SSR system co-channel coordinated control, with automatic calculation function, which can immediately correct temperature and humidity changing conditions, making temperature and humidity control more accurate and stable.

      3. Both temperature and humidity adopt high-precision controllers, and the relative temperature and humidity performance can be accurately set and displayed with a resolution of 0.1℃.

      (3) Heating and humidification system:

      1. Heating uses nickel-chromium alloy high-speed heating electric wire; 

      2. High temperature completely independent system; 

      3. The humidity adopts stainless steel tube with built-in nickel-chromium alloy high-speed heating wire and high-temperature magnesium oxide powder, which has fast response and long life. 

      4. The heating and humidification systems are completely independent, and the humidity has an automatic water replenishing device.

      (4) Control system:

      1. Adopt precision LCD display programmable temperature controller; 

      2. Intelligent digital display PID microcomputer temperature control instrument; 

      3. Touch setting, digital and direct display, the humidity directly displays the percentage, and the temperature sensor uses a PT100 platinum resistance Tester. 

      4. Temperature control adopts thermal balance temperature regulation method. 

      5. The precision liquid crystal display programmable temperature controller can be used for program testing. It can have multiple groups of multi-stage programming operations, optional fixed values ​​and programs, and the function of setting the time arbitrarily. 

      6. The main electrical components of the equipment, such as circuit breakers and AC contactors, are all of the "CHINT" brand, and other electrical accessories are of familiar domestic (CN) brands. 

      7. Convenient data processing: It can be connected to a printer or 232 communication interface, and has a USB data transfer interface (U disk). It can be displayed on a computer and print temperature, humidity and time curves, providing a strong guarantee for data storage and playback during the test process.

      (5) Protection system:

      Overall equipment overtemperature, fan overheating protection, overall equipment phase loss/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment timing, and other protections such as leakage, operating instructions, automatic shutdown after fault alarm, etc.

      Test Standard

      1.GB2423.1-2008/IEC6008-2-1-2007

      2. GB/T 2423.2-2008

      3. GJB150.3A-2009

      4. GJB150.4A-2009

      5. GB2423.22-2008

      6.GBT 2424.5-2006

      7. GB/T 10589-2008

      8. GB/T2423.3-2008(IEC68-2-3)

      VS

      HUDA QT-E702-408B70 Programmable Humidity ChamberSpecifications

      LIST VALUE
      Interior Volume 408L
      Temperature range -70~150℃
      Temperature Resolution 0.01℃
      Temperature Fluctuation ≤±0.5℃
      Temperature Uniformity ±2℃
      Humidity control range 20~98%R.H
      Humidity Deviation ±2%R.H
      Interior size 600*850*800mm
      Dimensions 1140mm×1750mm×1380mm
      Temperature deviation ≤±2℃
      Humidity resolution 0.1%R.H
      Temperature control Accuracy ±0.01℃
      Humidity Control Accuracy ±0.1%R.H
      Heating rate ≧3℃/min
      Cooling rate ≧1℃/min
      Refrigeration system 1 imported French Taikang fully enclosed compressor
      refrigerant Environmentally friendly refrigerant R404
      Refrigeration system Mechanical binary refrigeration method
      Wind circulation Centrifugal fan with forced circulation
      Condenser finned tube heat exchanger
      Condensation method air-cooled
      Condenser Stainless steel brazed plate heat exchanger
      Humidification system Stainless steel humidifier
      Heating system Nickel chromium alloy stainless steel heating device
      water supply system Front-mounted water supply tank, fully automatic water supply system
      Controller Taiwan, China Youyi Controller
      setting method Chinese/English interface, touch input
      operation mode Program method/valuation method
      setting range Maximum temperature range 5 ℃
      Display resolution Temperature: 0.01 ℃; Time: 0.1 min
      Power-off memory function The power failure recovery mode can be set as: hot start/cold start/stop
      input platinum resistance
      storage function Standard 2G SD card recording test data Linear dispersion, can upload and download data, can expand storage
      Safety Devices overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc
      Software Operating Environment IBM PC compatible computer, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system
      Enclosure Material SUS304 #stainless steel plate (1.0mm thick)
      Chamber material SUS #304 mirror stainless steel (1mm thick)
      Insulation material 100Mm polyurethane rigid foam + 100mm high density fiberglass cotton
      Weight 380kg
      Rated current 22A
      Rated power 11kw
      Power 380V
      test hole 100mm
      program amount Maximum 120 groups, 1 program can be combined from 1 to 99 segments, Capacity: 1200 segments
      Communication interface 1. R232/485 communication 2. Can display Linear dispersion, data acquisition 3. Can be used as monitoring and remote Control system

      HUDA QT-E702-408B70 Programmable Humidity Chamber Packing list

      machine X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      HUDA
      HUDA Aluminum profile coating Constant Temperature and Humidity Chamber QT-E702-408B70 -70 ℃/408L
      Service
      Focus on online sales of Lab Testing Instruments