      Home> Rain Test Chamber> HUDA> HUDA QD-E710-IPX3456-512 Rain Test Chamber
      HUDA QD-E710-IPX3456-512 Rain Test Chamber

      Haiyoda, rain Test Chamber QD-E710-IPX3456-512

      The equipment is used to simulate the performance of various equipment in a rain-drenched environment, conforming to GB2423, 38-90, GB4706.32-2004, and IEC-529 standards. The testing methods include IPX3 and IPX4, and are suitable for use in electronics, electrical equipment, lamps, electrical cabinets, electrical components, automobiles, motorcycles, and their parts, etc., to evaluate their durability and performance in humid environments.

      Brand
      SKU: NB041446
      China HUDA
      Stock
      Loading…
      Price
      $ 5484.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HUDA QD-E710-IPX3456-512 Rain Test ChamberOverview

        • Specifications
        • Comments
        • FAQs
        QD-E710-IPX3456-512
        Rain Test Chamber
        • Haiyoda, rain Test Chamber QD-E710-IPX3456-512
        The equipment is used to simulate the performance of various equipment in a rain-drenched environment, conforming to GB2423, 38-90, GB4706.32-2004, and IEC-529 standards. The testing methods include IPX3 and IPX4, and are suitable for use in electronics, electrical equipment, lamps, electrical cabinets, electrical components, automobiles, motorcycles, and their parts, etc., to evaluate their durability and performance in humid environments.

        Equipment use

        The main function of the equipment is to test the performance of the equipment during storage, transportation and use in the rainy climate environment. Components and other equipment are tested on the physical and other related properties of the equipment under simulated rainy weather conditions. After the test, the performance of the equipment is judged to meet the requirements through verification, so as to facilitate the design, improvement, verification and factory inspection of the equipment. .

        Executive standard

        GB2423,38-90, GB4706.32-2004 IEC-529

        test method

        1. IPX3 test method

        Sample placement: Select a swing tube with an appropriate radius so that the height of the sample table is equal to the diameter of the swing tube, place the sample on the sample table so that the distance from the top to the sample water nozzle is not more than 200mm, and the sample table does not rotate. 

        Test conditions: The water flow rate is calculated according to the water spray rate of the pendulum pipe, and each time is 0.07L/min. When spraying water, spray water from the water spray holes in the 60° arcs on both sides of the midpoint of the swing pipe to the sample. The sample to be tested is placed in the center of the semicircle of the swing tube. The swing tube swings 60° on both sides of the vertical line, a total of 120°. Each swing (2×120°) is about 4s.

        Test pressure: 80-150kPa 

        Test time: Continuous watering for 10 minutes; sample rotates 90° after 5 minutes of test

        2. IPX4 test method

        Sample placement: Select a swing tube with an appropriate radius so that the height of the sample table is at the diameter of the swing tube, place the sample on the sample table so that the distance from the top to the sample water nozzle is not more than 200mm, and the sample table does not rotate.

        Test conditions: The water flow rate is calculated according to the number of spray holes of the swing pipe, and each hole is 0.07±0.5L/min. The water spraying area is the water spraying holes in the 90° arcs on both sides of the midpoint of the pendulum pipe to the samples. The sample to be tested is placed in the center of the semicircle of the swing tube. The swing tube swings 180° on both sides of the vertical line, about 360° in total. Each swing (2×360°) is about 12s. Test pressure: 80-150kPa 

        Test time: Spray water continuously for 10 minutes and rotate the sample 90° after 5 minutes of test 

        Haiyouda QD-E710-IPX3456-225 Rain Test Chamber Details Figure 1

        VS

        HUDA QD-E710-IPX3456-512 Rain Test ChamberSpecifications

        LIST VALUE
        Inner box size 800*800*800mm
        Sample size 350X350mm
        Turntable diameter 600mm
        Power 380V / 12KW
        IPX34-pendulum tube Radius 400mm, (standard) Miscellaneous size can also be customized
        IPX34-Inner diameter of pendulum tube ¢16mm
        IPX34-Nozzle inner hole 0.4mm
        IPX34-Spray hole distance 50mm
        IPX34-pendulum tube material 304 stainless steel industrial pipe
        IPX34-Nozzle Angle IPX3: 120 °, IPX4: 180 °
        IPX34-pendulum tube angle IPX3:120 °, IPX4:320 ° (approximate)
        IPX34-Spray Pipe Swing Speed IPX3 15 times/min; IPX4 5 times/min about 2X360 degrees/12 S
        IPX34 - rain water pressure 80 ping 150Kpa
        IPX34 - Flow rate R400 pendulum tube: 1.75L/M
        IPX34 - Flow rate calculation Number of nozzle holes X0.07L/M = Flow rate of the water outlet of the pendulum pipe, the flow rate of the water spray can be set
        IPX56-Spray System 1 IPX5 nozzle, 1 IP6 nozzle
        IPX56-Nozzle Aperture IPx5: ¢6.3mm, IPx6: ¢12.5mm
        IPX56-Nozzle Connectivity Threaded connection, looper connection with water pipe, simple and convenient operation
        IPX56 - Flow rate IPX5: 12.5L / M ± 0.625L, IPX6: 100L / M ± 5L
        IPX56 - Injection time Universal standard 3 minutes, or more time can be set
        IPX56-Injection distance The sample is 2.5-3 meters away from the nozzle, and the distance is controlled by the Tester
        IPX56-Nozzle Connection Hose Inlet transparent hose with stainless steel wire
        IPX56-Nozzle Material 304 stainless steel

        HUDA QD-E710-IPX3456-512 Rain Test Chamber Packing list

        host X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Can this rain test chamber do IPX1-IPX2?
        [A]
        IPX1-2 is not available.