      Home> Humidity Test Chamber> kesionots> kesionots KS-HW1000A(100℃) humidity chamber

      KESIONOTS KS-HW1000A Programmable constant temperature and humidity test chamber 25~ 100 ℃/1000L

      Temperature range 25~ 100 ℃, Temperature Fluctuation +/- 0.5 ℃, Humidity range 20~ 98% R.H, Humidity stability +/- 2.0% R.H, volume 1000L, programmable 5.7 inch LCD color LCD display, RS-232 communication interface, with power failure memory function.

      Brand
      SKU: NB041490
      China kesionots
      Stock
      Loading…
      Price
      $ 9184.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • kesionots KS-HW1000A(100℃) humidity chamberOverview

        • Specifications
        • Comments
        • FAQs
        KS-HW1000A(100℃)
        humidity chamber
        • KESIONOTS KS-HW1000A Programmable constant temperature and humidity test chamber 25~ 100 ℃/1000L
        • KESIONOTS KS-HW1000A Programmable constant temperature and humidity test chamber 25~ 100 ℃/1000L Figure 1
        • KESIONOTS KS-HW1000A Programmable constant temperature and humidity test chamber 25~ 100 ℃/1000L Figure 2
        Temperature range 25~ 100 ℃, Temperature Fluctuation +/- 0.5 ℃, Humidity range 20~ 98% R.H, Humidity stability +/- 2.0% R.H, volume 1000L, programmable 5.7 inch LCD color LCD display, RS-232 communication interface, with power failure memory function.

        Introduction

        The temperature and Humidity Test Chamber can accurately simulate the natural environment of low temperature, high temperature, high temperature and high humidity, low temperature and low humidity, and is suitable for product reliability in various industries such as plastics, electronics, food, clothing, vehicles, metals, chemicals, and building materials. detection.

        Features

        1. With the function of automatic calculation;

        2. With constant temperature and slope setting function;

        3. With hold, skip, standby and two sets of time signal output functions;

        4. With cold engine/hot engine start selection function;

        5. With temperature display value correction function;

        6. With temperature sensing body correction function;

        7. It has the function of automatic stop and start of the compressor;

        8. It has the function of scheduled start/stop operation;

        9. With power failure memory function: after power failure, program data memory can be kept for 6 months;

        10. With powerful network monitoring and control network functions;

        11. It has a capacity of 1000 programs, each of which can cycle 999 steps, and the maximum value of each segment is 99 hours and 59 minutes;

        12. It has the function of fault alarm, reason and processing reminder;

        13. Has the upper and lower limit temperature protection function;

        14. With self-diagnosis function;

        15. Possess PC link air energy;

        Control System Features

        This machine adopts: TH-1200C/TEM880 programmable 5.7-inch LCD color liquid crystal display. System capacity: 120 groups of programs X 100 segments, the number of segments required by each group of programs can be divided arbitrarily, and each group of programs can be freely connected to each other. Cycle Setting: Each group of operation programs can be executed, 9999 times or countless cycles can be repeated, and at this level can be divided into 5 resistance segments to execute additional part of the cycle. Operation mode: fixed value/program/link and so on. The operation mode can meet the execution of various temperature test conditions. 

        1. Control method: intelligent microcomputer PID+SSR/SCR automatic forward and reverse bidirectional synchronous output.

        2. Data setting: Built-in program directory management, which facilitates the establishment, modification, inspection or operation of various test names and program data.

        3. Curve drawing: After the data setting is completed, the setting curve of relevant data can be obtained immediately, and the drawing screen of the actual operation curve can also be known during operation

        4. Timing control: 2 sets of timing output control interfaces, with 10 kinds of Timer Control modes, which can be used for external logic drive components to execute start/stop timing planning.

        5. Scheduled start: All test conditions can be set to schedule the start-up function.

        6. Operation lock: It can lock the functional conditions of start and stop to prevent other personnel from accidentally touching and affecting the experimental results.

        7. Power failure recovery: with power failure memory device and restart mode of the machine when power is restored 1. BREAK (interruption) 2. COLD (cold machine start) 3. HOT hot machine start).

        8. Safety detection: Built-in 15 full-featured system detection and sensing devices to ensure the safe operation of the machine. When abnormal faults are sensed, the control power of the machine will be cut off immediately, and the fault occurrence time and abnormal items will be automatically displayed. Troubleshooting and traceability: It can display the historical data of abnormal faults.

        9. External protection: an electronic over-temperature protection device independent of the controller.

        10. Communication interface: RS-232 standard communication interface device, which can be connected with a personal computer (PC) at the same time for multi-machine control and management

        11. Display switching: Chinese/English subtitles can be switched freely.

        12. Humidification system box-type water supply, manually add water 20L each time

        13. The weight of the product rack should be within 20 kg

        14. Two product test racks

        Cooling System

        The refrigeration system is one of the key parts of the comprehensive Test Chamber. Generally speaking, the refrigeration methods are mechanical refrigeration and auxiliary liquid nitrogen refrigeration. Mechanical refrigeration adopts vapor compression refrigeration. They are mainly composed of compressors, condensers, throttling mechanisms and evaporators. If the low temperature of our test should reach -55°C, single-stage refrigeration is difficult to meet the requirements, so the refrigeration method of the constant temperature and Humidity Chamber generally adopts cascade refrigeration. The refrigeration system of the constant temperature and Humidity Chamber consists of two parts, called the high temperature part and the low temperature part, each part is a relatively independent refrigeration system. The evaporation of the refrigerant in the high-temperature part absorbs the heat from the refrigerant in the low-temperature part and vaporizes; the evaporation of the refrigerant in the low-temperature part absorbs heat from the cooled object (air in the Test Chamber) to obtain cooling capacity. The high temperature part and the low temperature part are connected by an evaporative condenser, which is not only the condenser of the high temperature part, but also the condenser of the low temperature part. 

        Heating system

        The heating system of the Test Chamber is relatively simple compared to the refrigeration system. It is mainly composed of high-power resistance wires. Due to the high temperature rise rate required by the Test Chamber, the heating system power of the Test Chamber is relatively large, and a heater is also installed on the bottom plate of the Test Chamber. 

        6. Temperature and humidity system

        The temperature system is divided into two subsystems of humidification and dehumidification. 

        The humidification method generally adopts the steam humidification method, that is, the low-pressure steam is directly injected into the test space for humidification. This humidification method has high humidification ability, fast speed, and sensitive humidification control, especially when the temperature is lowered, it is easy to realize forced humidification. 

        There are two ways of dehumidification: mechanical refrigeration dehumidification and dry dehumidification. The dehumidification principle of mechanical refrigeration dehumidification is to cool the air below the dew point temperature, so that the water vapor greater than the saturated moisture content is condensed and precipitated, thus reducing the humidity. The dehumidification of the dryer is to use the air pump to extract the air in the Test Chamber, inject the dry air, and at the same time send the humid air into the recyclable dryer for drying, and then send it into the Test Chamber after drying, so that the cycle is repeated for dehumidification . At present, most comprehensive Test Chambers adopt the former dehumidification method and the latter dehumidification method, which can make the dew point temperature below 0°C. It is suitable for occasions with special requirements, but the cost is more expensive. 

        sensor system

        The sensors are mainly temperature and humidity sensors. Platinum electric groups and thermocouples are widely used in temperature sensors. There are two methods of measuring humidity: wet and dry bulb thermometer method and solid-state electronic sensor direct measurement method. Due to the low measurement accuracy of the dry-wet bulb method, the current constant temperature and Humidity Chambers are gradually replacing the dry-wet bulb with solid-state sensors to measure humidity.

        Related standards

        The performance indicators of the constant temperature and Humidity Chamber meet the requirements of GB5170, 2, 3, 5, 6-95 "Basic parameter verification methods for environmental test equipment for electrical and electronic products: low temperature, high temperature, constant damp heat, alternating damp heat test equipment": 

        Basic environmental test procedures for electrical and electronic products Test A: Low temperature test method GB2423.1-89 (IEC68-2-1) 

        Basic environmental test procedures for electrical and electronic products Test B: High temperature test method GB2423.2-89 (IEC68-2-2) 

        Basic environmental test procedures for electrical and electronic products Test Ca: Constant damp heat test method GB/T2423.3-93 (IEC68-2-3) 

        Basic environmental test procedures for electrical and electronic products Test Da: Alternating damp heat test method GB/T423.4-93 (IEC68-2-30) 

        GJB150.3 (ML-STD0-810D) high temperature test method 

        GJB150.4 (MIL-STD-810D) low temperature test method 

        GJB150.9-1986 "Military Equipment Environmental Test Method: Damp Heat Test" 

        GJB4.6-1983 "Environmental Test of Marine Electronic Equipment Alternating Humidity and Heat Test" 

        GJB367.2-1987 "Environmental Test Methods for General Technical Conditions of Military Communication Equipment" 411 Damp Heat Test 

        GJB4.5-1983 "Constant Damp Heat Test for Environmental Test of Ship Electronic Equipment" 

        GB10592-93 "Technical Conditions for High and Low Temperature Test Chambers" 

        GB10586-93 "Technical Conditions for Humidity and Heat Test Chamber" 

        GJB360.8-87 (MIL-STD-202f) high temperature life test 

        GB/T5170.2-96 "Temperature Test Equipment" 

        GB/T5170.5-96 "Damp Heat Test Equipment" 

        YD1268-2003 "Safety Requirements Standard for Mobile Communication Handset File Batteries and Chargers High Temperature Performance Test, Temperature Cycle Test, Thermal Shock Test" 

        UL1642 "Environmental Tests in Lithium Battery Standards - Heating and Thermal Cycle Test Methods and Requirements" 

        UN38.3 "Standard Regulations for Testing Lithium Batteries and Batteries - Temperature Test" 

        GB/T18287-2000 "General Specification for Lithium-ion Batteries for Cellular Phones High Temperature, Low Temperature, Constant Humidity Performance, Thermal Shock Test" 

        GB8897.4-2002 "Primary Batteries Part 4: Environmental Tests for Safety Requirements of Lithium Batteries - Thermal Shock and Thermal Abuse Tests" 

        UL2054-2005 "Environmental testing in battery standards - heating and thermal cycle testing" 

        SJ/T 11169-1998 "Lithium battery standard oven oven temperature cycle, temperature test" 

        GB8897.4-2002 "Primary Batteries Part 4: Environmental Tests for Safety Requirements of Lithium Batteries - Thermal Shock, High and Low Tests" 

        SJ/T11170-1998 "Heating and Temperature Cycle Test in Standard Environmental Test of Household and Commercial Batteries" 

        YD1268.2-2003 "Safety Requirements Standard for Battery Chargers of Mobile Communication Handsets Damp Heat Test" 

        QC/T743-2006 "Standard Heating Test of Metal Hydride Nickel Batteries for Electric Vehicles" 

        QC/T744-2006 "Standard Heating Test of Metal Hydride Nickel Batteries for Electric Vehicles"


        VS

        kesionots KS-HW1000A(100℃) humidity chamberSpecifications

        LIST VALUE
        Temperature range 25~100℃
        Temperature resolution ±0.1℃
        Temperature Fluctuation ±0.5℃
        Temperature Uniformity ±1℃
        Humidity Control Range 20~98%R.H
        Humidity stability ±2.0%R.H
        Humidity uniformity ±3.0%R.H
        heating rate ≈4.0℃/min
        Power supply voltage 220V AC (± 10%), protective ground wire, grounding resistance ≤ 4Ω;
        Inner chamber dimensions 1000*1000*1000mm
        Dimension 1500*1860*1570mm
        Studio volume 1000L
        Humidity resolution ±0.1%R.H
        Temperature control accuracy ±1.0℃
        Moisture control accuracy ±2.0%R.H
        display screen Programmable 5.7-inch LCD color LCD display
        communication interface RS-232
        display toggle Chinese/English display subtitles, can be freely switched.
        Product Test Rack 2
        safety device Air burn prevention, high voltage protection, overheating protection, overcurrent protection, ceramic E-16 fast fuse, no fuse overload protection
        Frequency 50±0.5Hz
        Power About 3.5KW
        Power switch Air switch (40A prohibits the use of knife switch or power socket)
        Humidification water resistivity ≥500MΩ
        Enclosure Material Advanced cold-rolled sheet nano-baking paint
        Insulation material High temperature resistant high density formic acid vinegar foam insulator material
        controller Korean "TEMI" "TH-900C" or Japanese "OYO" card to choose
        cooling rate ≈1.0℃/min
        Inner chamber material stainless steel

        kesionots KS-HW1000A(100℃) humidity chamber Packing list

        host X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        kesionots KS-HW1000A(100℃) humidity chamber Library

        FAQ

        [Q]
        We mainly measure the Reliability of electronic products in high temperature and high humidity environment. It is enough to control the temperature to 100 ° C. Is there a suitable instrument recommended?
        [A]
        Yes, this humidity Chamber Temperature range 25 to 100 ℃, humidity control 20 to 98% R.H. Humidity stability and uniformity are good, with programmable controller can run alternating heat and humidity program, just cover the high temperature and humidity of electronic products and constant heat and humidity testing needs, 1000L studio volume is also enough to put multiple sets of samples.
        [Q]
        I want to test the Reliability of electronic products in a high temperature and high humidity environment. The maximum temperature needs to reach 100 ° C, and the Humidity range should be wider. Is there any suitable equipment recommended?
        [A]
        A humidity chamber with a maximum temperature of 100 ° C is recommended. Its Humidity control range is very wide, which can meet your requirements for high temperature and high humidity testing of electronic products. This device has high temperature and humidity control accuracy and small fluctuations, which can accurately simulate the harsh environment you need and ensure the Reliability of test results.
        [Q]
        When selecting a Constant Temperature and Humidity Chamber, in addition to the Humidity range, what other functions are more practical and efficient in actual use?
        [A]
        In addition to the core Humidity performance, there are several functions that are very practical. One is the appointment start and power failure memory function, which can set up the experiment in advance, and the data can be saved after the power failure, which is worry-free. The second is the network communication and PC connection function, which is convenient for remote operation and monitoring on the computer, and the data management is also more efficient. The third is that it comes with fault diagnosis and Safety protection prompts. If there is a problem, you can quickly know the cause, ensure the safety of the experiment, and reduce downtime.
        +kesionots KS-HW1000A(100℃) humidity chamber Big data
          +kesionots KS-HW1000A(100℃) humidity chamberKnowledge
          +kesionots KS-HW1000A(100℃) humidity chamberStandard
          +Navigation
          kesionots
          KESIONOTS KS-HW1000A Programmable constant temperature and humidity test chamber 25~ 100 ℃/1000L
          Service
          Focus on online sales of Lab Testing Instruments