3NH PS2010 Colorimeter φ 8mm caliber
CMOS dual-channel spectroscopic Sensors, equipped with the measurement diameter of the φ 8mm platform, contact automatic whiteboard calibration, for plastic electronics, paints inks, Spinning & weaving clothing printing, printing, ceramics, etc.
3NH-
Kutai MS3012 discoloration paints Colorimeter 12 Measurement angles
Login -
EVERFINE PSC-30H Portable Colorimeter high-precision type
Login -
Sanenchi/3NH YS3010 Economical Grating Colorimeter Standard φ 8mm measurement diameter
Login -
EVERFINE HACA-3800 High Precision Color Analyzer
Login -
3NH YS6003 Desktop Colorimeter
Login
Introduction
"Pang Niu" is the nickname of the domestic (CN) Spectrophotometer PS series. "Pang Niu" is serious about color measurement and has high customer satisfaction.
PS2010 "Pang Niu" Spectrophotometer is developed by 3nh with CMOS dual-channel spectroscopic sensor. It is not only a Spectrophotometer , but also a Spectrophotometer . The comfortable and sleek appearance is even more addictive, and the quality management software is attached to facilitate quality monitoring and data management.
The PS2010 spectroColorimeter is equipped with a Φ8mm platform measuring caliber, which is used for color quality control in various industries such as plastic electronics, paint ink, textile and garment printing and dyeing, printing, and ceramics.

Technical advantages
1. Using the internationally accepted D/8 SCI/SCE synthesis technology
SpectroColorimeter PS2010 adopts D/8 lighting observation conditions widely applicable in the world, SCI/SCE (including specular reflection/not including specular reflection) synthesis technology, suitable for color matching and coatings, textiles, plastics, food, building materials in various industries Color management and quality control in cosmetics, cosmetics and other industries.

2. Adopt full-band balanced LED light source
The 400~700nm full-band balanced LED is used as the instrument lighting source, which has sufficient spectral distribution in the visible light range, avoiding the spectrum loss of white LEDs in specific bands, and fluorescent materials can also be easily measured, ensuring the accuracy of the instrument’s measurement results.

3. CMOS dual beam splitting sensor
High-speed, high-sensitivity CMOS dual-channel spectroscopic sensor makes color data processing more effective and accurate

4. Automatic whiteboard verification
The Spectrophotometer PS2010 is equipped with an intelligent calibration base, which can perform contact-type automatic whiteboard calibration. The professional-grade standard whiteboard reflectance R%≥95% has good surface uniformity and high stability, and can obtain repeated and accurate data.

5. A variety of color measurement spaces, a variety of observation light sources
SpectroColorimeter PS2010 provides CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy, DIN Lab99 color space, and D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30), U35, NBF, ID50, ID65 various observation light sources, which can meet different measurements Special measurement needs under certain conditions.

6. Ergonomic design and easy-to-test device
The Spectrophotometer PS2010 has a beautiful, smooth shape and comfortable grip. The structural design conforms to the human body mechanics. It fits the palm and is suitable for continuous testing. It makes you use it quickly and easily. It adds an easy-to-measure device for automatic measurement Portable, fast, easy to test and easy to use.

7. Measurement verification report
Each Spectrophotometer PS2010 has been verified and tested. After leaving the factory, each instrument is verified according to the measurement standards of the credible verification department. The measurement data is traceable to the National Metrology Institute to ensure the reliability of the instrument test data.
8. Color management software
The quality management software SQCX is suitable for quality monitoring and color data management in various industries. Dataize the user's color management, compare color differences, generate test reports, provide a variety of color space measurement data, and customize the customer's color management work.

3NH PS2010 Spectroscopic ColorimeterSpecifications
| LIST | VALUE |
|---|---|
| Lighting method | D/8 (diffuse lighting, 8 ° direction reception), SCI/SCE (including specular light/removing specular light), in line with standards CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| lighting source | Light spectrum LED light source |
| Integrating sphere size | F40mm |
| sensor | CMOS Dual Spectroscopic Sensors |
| Measurement Wavelength range | 400-700nm |
| Measurement caliber | Single diameter: Φ8mm/Φ10mm (platform measurement diameter) |
| Light-containing method | Simultaneous testing of SCI/SCE |
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
| Other chromaticity indicators | Light spectrum reflectance, WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), monochromatic index Mt, lightfastmess, color fastness, force, occlusion, 555 hue classification, Munsell (C/2) (mobile APP implementation) |
| Observer angle | 2°/10° |
| Observation light source | D65,A,C,D50,D55,D75,F1,F2 (CWF),F3,F4,F5,F6,F7 (DLF),F8,F9,F10 (TPL5),F11 (TL84),F12 (TL83/U30),U35,NBF,ID50,ID65 |
| show | Light spectrum graphs/data, sample chromatic values, color difference values/graphs, pass/fail results, Color simulation, Color bias |
| Measurement time | About 1s |
| Sexual repeability | Chromatic value: MAV/SCI, standard deviation ΔE * ab within 0.04 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectral reflectance: MAV/SCI, standard deviation within 0.1% (400~700nm: within 0.2%) |
| display Accuracy | 0.01 |
| Reflectance Measurement Range | 0-200% |
| Reflectance resolution | 0.01% |
| Measurement method | Single measurement, average measurement (2~ 99 times) |
| Positioning method | Stabilizer positioning |
| Whiteboard verification method | Contact automatic whiteboard verification |
| size | Length X width X height = 94X68X188mm |
| Weight | 270G (without calibration base) |
| Battery level | Lithium battery, 3.7V, 5000mAh, 8000 times in 8 hours |
| Lighting source life | More than 1.20 million measurements in 10 years |
| Display | TFT true color 2.8inch, capacitive touch screen |
| interface | USB |
| Store data | 500 master standards, 5000 samples (one piece of data can include SCI/SCE at the same time), PC Mass storage |
| Software Support | Windows |
| language | Simplified Chinese, English, Traditional Chinese |
| Operating temperature range | 0~40 ℃, 0~85% RH (no condensation), altitude: less than 2000m |
| Storage temperature range | -20~50 ℃, 0~85% RH (no condensation) |
| Standard accessories | Power adapter, data cable, manual, quality management software (official website download), black and white correction box, protective cover, wristband, measurement caliber |
| Optional accessories | Micro printer, powder test box |
3NH PS2010 Spectroscopic Colorimeter Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Color difference meter can be used for color detection and comparison of broccoli
- Key application and advantages of color difference meter in the detection of advertising cloth coatings color difference
- Application of color difference meter in construction industry
- The measurement procedure of color difference meter in shrimp skin color difference detection
- Types and applications of functional pigments
- Application of color difference meter in purple rice color difference detection and its measurement procedure
- Detailed explanation of application and test method of colorants' lightfastness
- Application analysis of color difference meter in ink printing color difference detection
- The measurement procedure of color difference meter in metal parts
- ActiveGB/T 44757-2024
- ActiveGB/T 43846.2-2024
- ActiveJJF 1990-2022
- AbolishJB/T 5595-1991
- ActiveSH/T 1833-2022
- AbolishGB/T 7921-1997
- AbolishGB/T 12967.6-2008
- ActiveGB/T 39135-2020
- ActiveGB/T 3810.16-2016
- ActiveGB/T 12967.6-2022
- ActiveGB/T 7921-2008
- ActiveGB/T 36142-2018
- ActiveGB/T 33568-2017
- ActiveGB/T 11942-2022
- ActiveJJG 595-2002
- ActiveISO 11664-6-2022
- ActiveQB/T 5160-2017
- ActiveQB/T 2789-2006
- ActiveQB/T 1503-2011
- ActiveHG/T 3862-2006


PS2010