KEXIN QGZ - 6-12-24 drying performance Tester for determining drying time of paint film and putty film
The number of strokes is 4, the size of the strokes is R 0.25/0 5/1.0/1.5mm, the track period is 6/12/24h, the sample size is 200 * 200 * (0.2~ 3) mm, and the track period is 6/12/24h/T.
KeXin-
TQC sheen AB3600 Drying Time Recorder BK method, six-track -20 ℃ to 70 ℃ test
$ 4189.00 -
KEXIN BZT Non-stick Tire Time Tester
$ 201.00 -
PUSHEN GZY-I Linear Drying Time Recorder
$ 724.00 -
CHINA QGZ-A Linear Paint Film Drying Time Recorder
$ 444.00 -
MODERNER GZY-III Drying Time Recorder Linear Drying Time Recorder
Login
The paint is in the form of a liquid and has a certain viscosity. After being painted on the surface of the utensils by different decoration methods such as brushing, spraying, pouring, and rolling, some of them are in the normal temperature of the atmosphere, and some are in a heated state. A chemical and physical change process, called the drying process of the coating. The drying time meter is mainly used to measure the time required for this process. It will play a very important role in improving the production efficiency of the coating process.
product description
The various stages of coating drying and curing are easy to detect, but defining them in terms of chemical and mechanical principles is not so simple. In order to get a satisfactory evaluation, it is necessary to use instruments to measure under controlled conditions, and the drying time Tester was conceived.
Specifications
| model | QGZ-6-12-24 |
| Needle radius | 0.25/0.5/1.0/1.5mm |
| track period | 6, 2, 24h/T |
| Sample size | 200×200×(0.2-3)mm |
| use | Determination of drying time of paint film and putty film |
KeXin QGZ-6-12-24 Drying performance TesterSpecifications
| LIST | VALUE |
|---|---|
| Number of strokes | 4 stitches |
| Scribing needle specification | R 0.25/0.5/1.0/1.5mm |
| Specimen size | 200*200*(0.2~3)mm |
| trajectory period | 6/12/24h/T |
KeXin QGZ-6-12-24 Drying performance Tester Packing list
Drying performance tester x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveASTM D5895
- ActiveISO 9117-4
- ActiveDIN EN ISO 9117
- ActiveHG/T 3357-2003
- ActiveHG/T 5173-2017
- ActiveJG/T 210-2018
- ActiveJC/T 975-2005
- ActiveJG/T 298-2010
- ActiveJC/T 2090-2011
- ActiveASTM
- ActiveJT/T 821.1-2011
- ActiveDL/T 2308-2021
- ActiveJG/T 224-2007
- ActiveSY/T 4106-2016
- ActiveHG/T 5060-2016
- ActiveHG/T 4338-2012
- Active 0025-2018
- ActiveHG/T 5176-2017
- ActiveHG/T 5059-2016
- ActiveDB 44/T 1106-2012


QGZ-6-12-24