ASR-9017 battery combustion Tester
Used for battery flame resistance test, nozzle inner diameter 9.5mm, length about 100mm, automatic control automatic ignition, in line with UL1642, SJ/T11170 and other test methods.
AISRY-
Huicheng DTA-1250 Differential Thermal Analyzer Differential Thermal Analysis Linear dispersion 1250 ℃
$ 3537.00 -
DUBAN DBF25-204PB Pedal Force Handbrake Force Tester
$ 404.00 -
XINGHUO ZTT-980 Silicon Core Tube Cold Bending Radius Tester
$ 2361.00 -
Wasites DSS-2A Computer digital flashing speedometer
$ 190.00 -
CHINA NBC-YX-6050 Manual 2D Imager 600 × 500mm
$ 7051.00
Applications
The battery combustion test machine is mainly used for the battery flame resistance test. This battery performance test is mainly to test the reliability of the battery safety performance when the battery encounters an open flame, and the battery flame resistance performance.
Product principle
The test sample (battery) should be placed 38.1mm above the top of the burner by fixing the mesh screen. The mesh screen has 20 holes every 25.4mm, and the diameter of the steel wire is 0.43mm; light the burner and observe the combustion of the battery at the same time. Until the battery explodes or the battery burns; and the burning process is timed.
control Panel

According to the standard
This instrument can meet the requirements of UL1642, SJ/T11170 and other test methods, and many other test methods.
Instrument Installation and Setup
Operating environment requirements: room temperature within the range of 10°C-40°C; ambient humidity within 30%-80%
Others: The machine must be installed and positioned on a level platform with a certain strength.
It is required that the laboratory has good ventilation performance and is convenient for exhaust gas.
Steps
First confirm that the power supply Voltage is 220V, connect the power supply, turn on the power switch, and the fan starts randomly.
Turn on the power switch to see if the instrument is powered on.
Place the sample to be tested on the test net, and confirm whether the sample to be tested is placed directly above the Bunsen burner.
Close the door of the test case, set the time to be tested, press the "Start" button, the electronic igniter will start to ignite, and the test will automatically stop when the set time is up. After the test is completed, it will take 5-10 minutes to take out the sample and take the test. Be sure to use anti-scalding gloves when handling the passed samples and complete a test.
Select remote control test, the operation method is the same as above.
Precautions
The test sample should be a non-deformed sample or a sample with the casing package intact, so as not to affect the test Conclusion.
Before the test, the door of the Test Chamber must be closed to prevent safety accidents.
Each sample battery can only be tested once. Different samples are used for each test.
AISRY ASR-9017 Battery combustion testing machineSpecifications
| LIST | VALUE |
|---|---|
| Combustion device | Bunsen lamp, the inner diameter of the nozzle is 9.5mm, and the length is about 100 mm. |
| Flame application time | 0~999.9 seconds ± 0.1 seconds |
| Test hole surface diameter | 102mm |
| automatic control | Automatic ignition, automatic control of test process |
| Use gas | Liquefied gas, or methane |
| Test cover width | 24 (610mm), octagon |
| Test cover height | 12″(305mm) |
| component | Including combustion and support frame, test table, standard metal mesh, standard metal mesh screen |
| Operating conditions requirements | Room temperature within the range of 10 ℃ -40 ℃; environment humidity within 30% -80% |
| other | The machine needs to be installed and positioned on a horizontal platform with a certain strength |
AISRY ASR-9017 Battery combustion testing machine Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


ASR-9017