Aipei 3AP-CJ-100A Three-Chamber Thermal Shock Test Chamber air-cooled -40 ℃
France Taikang compressor, touch screen programmable temperature controller, temperature control -40 ℃~ + 150 ℃, volume 100L, real-time temperature Linear dispersion display, in line with GB\ GJB standard.
Apkjgroup-
Aipei 3AP-CJ-27C Three-Chamber Thermal Shock testing device Air-Cooled -65 ℃
$ 16673.00 -
Aipei 2AP-CJ-80B Two-Chamber Thermal Shock Test Chamber Air-Cooled -55 ℃
$ 17326.00 -
Aipei 2AP-CJ-50C Two-Chamber high and low temperature impact test chamber Air-Cooled type -65 ℃
$ 18430.00 -
Aipei 3AP-CJ-80C Air-Cooled Thermal Shock Box -65 ℃
$ 19518.00 -
Aipei 3AP-CJ-50C Three-Chamber Thermal Shock Test Chamber Air-Cooled -65 ℃
$ 18865.00
control instrument
The 7-inch extra-large touch AP-950 programmable temperature controller is a full touch screen controller independently developed by Aipei. With touch screen input, different high-low temperature impact temperature points can be set arbitrarily according to customer requirements to meet different needs for testing. (With temperature alarm display, real-time temperature curve display).

Applications
Widely used in electronic and electrical components, plastics and other industries, automation parts, communication components, auto parts, metals, chemical materials, plastics and other industries, defense industry, aerospace, ordnance industry, BGA, PCB base plate, electronic chip IC, semiconductor ceramics It is used to test the physical changes of polymer materials. It is used to test the degree to which the material structure or composite material can endure the continuous environment of extremely high temperature and extremely low temperature in an instant, so as to test its thermal expansion and contraction in the shortest time. chemical or physical changes caused.
Features
1. The Three-Chamber equipment area is divided into three parts: high temperature area, low temperature area and test area. The test sample is completely stationary in the test area. Using a unique heat storage and cold storage structure, the forced hot and cold air path switching method is introduced into the test area. During impact, the temperature in the high temperature zone or low temperature zone rushes into the test area for impact, completing the hot and cold temperature shock test.
2. The function of three different conditions of high temperature, low temperature and hot and cold shock can be independently set. When executing the hot and cold shock conditions, the function of 2 boxes or 3 boxes can be selected and it has the function of a high-low temperature testing machine. Compared with the 2 boxes The impact can also be done at room temperature.
fulfill the standard
GB/T2423.1-2008 Test method of low tempemture test
GB/T2423.2-2008 Test method of high temperature test
GB/T2423.22-2012 Test of temperature chantge
GJB150.5-86 Temperature shock test Test of temperature shock
GJB360.7-87 Temperature shock test Test of temperature shock
GJB367.2-87 Temperature shock test Test of temperature shock
QC/T17-92, EIA364-32, IEC68-2-14, etc.
Advantages of insulation materials
Box insulation material: rigid polyurethane foam, its advantages are:
1. Effective energy saving, no gaps after filling, strong bonding after curing.
2. Shockproof and compression resistant, it will not crack, corrode or fall off after curing.
3. It has ultra-low temperature thermal conductivity, weather resistance and heat preservation.
4. Effective insulation, sound insulation, waterproof and moisture-proof after curing.
5. Good waterproof performance, because the foam holes are closed, with a closing rate of 95%, and rainwater will not seep through the holes.
Names and functions of each part of the Test Chamber
â High temperature room: used to store heat
â¡Laboratory: The part where samples are placed for testing
⢠Low temperature room: used to store cold energy
â£Main power board: including main power switch, sample power control terminal, external alarm output terminal, test end output terminal, temperature arrival output terminal, RS-232 communication interface, and operation panel cover lock
â¤Operation panel: including controller, fault indicator light, over-temperature protection setter, temperature Recorder (optional)
â¥Power distribution room: Install electrical components
â¦Mechanical room: Install refrigeration unit and exhaust fan
â§Air inlet: suck in outside air when exposed to ambient temperature
â¨Exhaust port: Exhaust hot air from the mechanical room and test room
â©Temperature Recorder (optional) records the temperature in each room of the temperature shock Test Chamber
safety protection device
1. Refrigeration system: compressor overpressure, compressor overheating, compressor overflow, circulating cooling water supply underpressure
2. Test room: test room over-high-low protection (controller built-in), test room over-high-low protection, test room door opening protection
3. Others: main power supply phase sequence and phase loss protection relay, leakage circuit breaker, sample power control terminal, external alarm output terminal, high/low temperature room over-temperature protection switch, high/low room over-temperature protection (built-in controller) , circulating fan thermal relay, motor temperature switch, compressed air pressure switch, exhaust valve
Other configurations
â»The user is required to configure an air or power switch of corresponding capacity at the installation site, and this switch needs to be independently used for this equipment. AC380V power supply requirements:
1. Three-phase four-wire + protective ground wire
2. Voltage range: AC (380±10) V
3. Allowable frequency fluctuation range: (50±0.5) Hz
4. The ground resistance of the protection line is less than 4Ω
This plan does not include the installation of external environmental items such as ventilation ducts, power supply (leakage switch), air source (Air Compressor), water source (barrel water or water pipe), etc.
Apkjgroup 3AP-CJ-100A Thermal Shock Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -40 ℃~ + 150 ℃ (air-cooled) |
| Temperature Fluctuation | ±0.5℃ |
| Temperature deviation | ±2.0℃ |
| Weight | About 750 kilograms |
| Inner Volume | 100L |
| Liner size | 500*500*400mm |
| Dimensions | 1500*2000*1650mm |
| Low Temperature Impact Range | -10 ℃~ -40 ℃ (optional) |
| High Temperature Impact Range | 60 ℃~ 150 ℃ (arbitrarily adjustable) |
| Test environmental conditions | Environmental temperature around the machine is maintained between + 25~ + 30 ℃, Relative Humidity: ≤ 85%; air pressure: 86kPa~ 106kPa normal atmospheric pressure. |
| High Temperature Impact Range | RT~+165℃ |
| Heating rate | +50℃→+165℃ ≤30min |
| Low Temperature Impact Range | RT~-55℃ |
| Cooling rate | + 20 ℃ → -55 ℃ ≤ Technologies 60min; Note: The cooling time is the performance of the low greenhouse when running alone |
| Test method | Using heat storage, cold storage structure, strong cooling hot air circuit switching mode into the test area, Impact high temperature zone or low temperature zone temperature into the test area Impact, complete the hot and cold temperature Impact test. |
| temperature recovery time | ≤ 5min; the conversion temperature only needs ≤ 10s (throttle opening time: within 3 seconds) |
| Impact exposure time | ≥30min |
| Enclosure Material | The outer material can be selected from SUS304 good stainless steel or fine powder paint treatment |
| Liner material | Stainless steel plate (SUS #304) |
| Box insulation material | Rigid polyurethane foam |
| Air conditioning channel | Fan, heating device, evaporator, damper, temperature sensor |
| Specimen shelf | 1 set, a total of two layers (with four hooks) bearing 25KG (please indicate when placing an order for larger bearing) |
| Lead Hole | (Optional) 1, located on the left side of the box, with a round hole with a size of 0019 50mm |
| Test chamber door | Single open, left hinge, right handle |
| Circulating Fan | High temperature/ambient temperature exposure: 3φ, 400W, centrifugal; low temperature exposure: 3φ, 400W, centrifugal |
| Control Panel | Controller display, fault indicator, timer, USB or R232 interface, over-temperature protection setter, main power switch |
| Mechanical room | Refrigeration unit, connected drainage device, exhaust fan |
| Distribution control cabinet | Total power leakage circuit breaker, Controller, distribution board, heat dissipation fan, high and low temperature Circulating Fan motor |
| Heating system | Nickel chromium alloy heating wire heating device |
| Control mode of heating | No touchpoint equal period pulse width modulation, SSR (solid state relay) |
| Power cord holes and drainage holes | Located on the back of the box |
| Refrigeration system | France Taikang or Japan Hitachi fully enclosed low noise rotary compressor |
| Evaporator | finned tube heat exchanger |
| Condenser | shell and tube heat exchanger |
| Throttle device | Thermal expansion valve, capillary tubing |
| Evaporative condenser | Stainless steel brazed plate heat exchanger |
| Control mode of refrigerator | Control system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator according to the test conditions, compressor return air chill down circuit, energy regulation circuit, condensing pressure control valve |
| refrigerant | R404a/R23 |
| Controller | 7 inch large touch AP-950 programmable temperature Controller full touch screen Controller |
| monitor | LCD liquid crystal display |
| operation mode | procedural approach |
| setting method | All Chinese LCD display (Chinese and English can be switched) LCD touch panel (resistant to 100.000 line drawing test) |
| program Capacity | Up to 120 groups, each program is divided into two or three zones, two zones have 2 segments, and three zones have 3 segments. Each command can be up to 999 times; the program segment time is set to 0~999Hour59Min |
| Display resolution | Temperature: 0.1 ℃; Time: 0.1 min |
| electrical input | Thermocouple |
| storage device | USB and R232 communication interface |
| Control mode | Anti-integral saturation PID, fuzzy algorithm; BTC equilibrating temperature control mode |
| Curve recording | Real-time display of graphics during program execution Linear dispersion |
| subsidiary function | It has power-off program memory, automatically starts and continues to execute program functions after power-back, with date, time adjustment, appointment start, shutdown function and screen lock (LOCK) function. |
| Environmental conditions | Temperature: 5 ℃~ 35 ℃; Relative Humidity: ≤ 85%; air pressure: 86kPa~ 106kPa normal atmospheric pressure. |
| air source pressure | (5~7)kg/cm2 |
| Air source connecting pipe diameter | Φ8mm |
| Flow rate of air source | 0.1m3/min |
| Maximum Power | Approx. 10.0KW [Voltage range: no more than +/- 10%] |
| Storage environment | When the equipment is not working, the temperature of the environment should be kept within 0 ℃~ + 45 ℃; when the Environmental temperature is lower than 0 ℃, the water remaining in the equipment should be discharged clean to avoid the water in the pipeline freezing and damaging the pipeline. |
| Maximum current | 15A |
Apkjgroup 3AP-CJ-100A Thermal Shock Test Chamber Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Precision heat & cold shock testing device
- Principle, Application and Selection of Main board Thermal Shock Test Chamber


3AP-CJ-100A