YUEFENG FP6426 Flame photometer K/Ba
To test potassium and barium elements, the ranges are 0.0-10.0mmol/L and 0-22mmol/L, respectively. Liquefied petroleum gas is used as fuel, the sample quantity is small, and it has the function of flameout protection.
YUEFENG-
YUEFENG FP6422 Flame photometer Li/Ba
$ 1439.00 -
YUEFENG FP6421 Flame photometer Li/Ca
$ 1439.00 -
YueFeng FSP6642 Flame Spectrophotometer Test Potassium/Sodium/Lithium/Barium
$ 3413.00 -
YueFeng FP640 Flame photometer K: 0.0~2.0mmol/L
$ 747.00 -
JINGHUA 7600 Dual beam of light UV-Visible Spectrophotometer Wavelength Accuracy : +/- 0.5nm
$ 4423.00
Features
The appearance is small, exquisite and beautiful.
Dual-channel LED digital display 4-digit digital display per channel, clear readings.
Unique ignition gas circuit, push-button automatic ignition, fast and reliable ignition.
Potassium and sodium can be detected at the same time, and it has the detection function of lithium calcium.
Using silicon photocell detection, the measurement results are accurate and stable.
Small amount of sample, high sensitivity.
Use liquefied petroleum gas as fuel, easy to use.
With flameout protection function, safe and reliable performance
FP flame photometer element parameter table
| element | Measuring range | linearity error | detection limit |
| Lithium | 0~15mmol/L | ≤0.02 | ≤0.015 |
| Ca calcium | 0~25mmol/L | ≤0.07 | ≤0.050 |
| Barium | 0~22mmol/L | ≤0.065 | ≤0.100 |
| Potassium K | 0.0~10.0mmol/L | ≤0.005 | ≤0.004 |
| Sodium | 0.0~200.0mmol/L | ≤0.03 | ≤0.008 |
YUEFENG FP6426 Flame photometerSpecifications
| LIST | VALUE |
|---|---|
| K Measurement range | 0.0-10.0mmol/L |
| Stability measurement | The maximum deviation of the indication within 15S is ≤ 2%, measured once per minute, and the maximum deviation of the indication measured 6 times in total is ≤ 10% |
| K measurement Repeatability | Relative standard deviation ≤ 2% |
| K measurement detection limit | ≤0.004 |
| K measurement Linearity | ≤0.005 |
| Ba Ba Measurement range | 0-22mmol/L |
| Ba Ba measurement Repeatability | Relative standard deviation ≤ 3% |
| Ba measurement detection limit | ≤0.100 |
| Barium Ba measurement Linearity | ≤0.065 |
YUEFENG FP6426 Flame photometer Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Application of Flame Atomic Absorption Spectrophotometry in Detection of Food Talc Powder
- Working mechanism, common types and performance considerations of light stabilizers
- ActiveGB/T 713.2-2023
- ActiveASTM D4185-23
- ActiveGB/T 3260.1-2024
- ActiveGB/T 693-2024
- ActiveGB/T 44215-2024
- ActiveSL/T 788.4-2019
- ActiveSL/T 788.5-2019
- ActiveSL/T 788-2019
- ActiveHJ 668-2013
- ActiveSL/T 788.1-2019
- ActiveGB/T 38216.5-2024
- ActiveGB/T 42513.7-2024
- ActiveGB/T 6730.89-2024
- ActiveHB 20056.1-2011
- ActiveYB/T 4217.1-2010
- ActiveYS/T 514.7-2009
- ActiveHJ 601-2011
- ActiveQX/T 216-2013
- Active 01010102-2006
- ActiveGB/T 15262-1994


FP6426
FP6429
FP6428
FP6427
FP6425
FP6423
FP6421