YUEFENG FP6429 Flame photometer Na/Ba
Test sodium and barium elements, the range is 0.0~200.0mmol/L and 0~22mmol/L, respectively, using liquefied petroleum gas as fuel, the sample quantity is small, and it has the function of flameout protection.
YUEFENG-
YueFeng 770S Ultraviolet-visible spectrophoto-meter full-band/sub-band scanning
$ 2496.00 -
JINGHUA UV1900 UV-Visible Spectrophotometer Wavelength range: 190nm~ 1100nm
$ 3491.00 -
JINGHUA 5cm Colorimetric dish, width 5cm
$ 110.00 -
YueFeng FP6450 Flame photometer for cement industry, testing potassium/sodium
$ 871.00 -
JINGHUA 722 visible spectrophotometer high performance grating, low stray light, wide sample chamber
$ 350.00
Flame photometer is an instrument commonly used in the fields of analytical chemistry and metal analysis. It can quantitatively analyze the content of metal ions in samples by measuring the emission spectrum of metal ions in the flame. Among them, sodium and barium are commonly used analytical elements, so the flame photometer can be used to detect the content of sodium and barium.
Features
The appearance is small, exquisite and beautiful.
Dual-channel LED digital display 4-digit digital display per channel, clear readings.
Unique ignition gas circuit, push-button automatic ignition, fast and reliable ignition.
Potassium and sodium can be detected at the same time, and it has the detection function of lithium calcium.
Using silicon photocell detection, the measurement results are accurate and stable.
Small amount of sample, high sensitivity.
Use liquefied petroleum gas as fuel, easy to use.
With flameout protection function, safe and reliable performance
FP flame photometer element parameter table
| element | Measuring range | linearity error | detection limit |
| Lithium | 0~15mmol/L | ≤0.02 | ≤0.015 |
| Ca calcium | 0~25mmol/L | ≤0.07 | ≤0.050 |
| Barium | 0~22mmol/L | ≤0.065 | ≤0.100 |
| Potassium K | 0.0~10.0mmol/L | ≤0.005 | ≤0.004 |
| Sodium | 0.0~200.0mmol/L | ≤0.03 | ≤0.008 |
YUEFENG FP6429 Flame photometerSpecifications
| LIST | VALUE |
|---|---|
| Na Measurement range | 0.0-200.0mmol/L |
| Repeatability of Na measurement | Relative standard deviation ≤ 2% |
| Na measurement detection limit | ≤0.008 |
| Linearity measurement | ≤0.03 |
| Stability measurement | The maximum deviation of the indication within 15S is ≤ 3%, measured once per minute, measured 6 times in total, and the maximum deviation of the indication is ≤ 10% |
| Ba Ba Measurement range | 0-22mmol/L |
| Ba Ba measurement Repeatability | Relative standard deviation ≤ 3% |
| Ba measurement detection limit | ≤0.100 |
| Barium Ba measurement Linearity | ≤0.065 |
YUEFENG FP6429 Flame photometer Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Application of Flame Atomic Absorption Spectrophotometry in Detection of Food Talc Powder
- Working mechanism, common types and performance considerations of light stabilizers
- ActiveGB/T 713.2-2023
- ActiveASTM D4185-23
- ActiveGB/T 3260.1-2024
- ActiveGB/T 693-2024
- ActiveGB/T 44215-2024
- ActiveSL/T 788.4-2019
- ActiveSL/T 788.5-2019
- ActiveSL/T 788-2019
- ActiveHJ 668-2013
- ActiveSL/T 788.1-2019
- ActiveGB/T 38216.5-2024
- ActiveGB/T 42513.7-2024
- ActiveGB/T 6730.89-2024
- ActiveHB 20056.1-2011
- ActiveYB/T 4217.1-2010
- ActiveYS/T 514.7-2009
- ActiveJB/T 10058-2000
- ActiveHJ 601-2011
- ActiveQX/T 216-2013
- Active 01010102-2006


FP6429
FP6428
FP6427
FP6426
FP6425
FP6424
FP6423
FP6422
FP6421
FP6455