TASI TASI-605A Digital thermometer greenhouse, laboratory, environment research, climate monitoring, art gallery, factory, etc
TASI TASI-605A digital thermometer, dual channel Thermocouple Thermometer, K/J type thermocouple optional, with USB data transfer function, and read recovery and retention function.
TASI-
HANNA HI93531 Single Channel Wide Range Temperature Meter
$ 455.00 -
Wasites WT200-8 Intelligent 8-way Temperature Logger Linear dispersion thermometer
$ 817.00 -
Wasites WT200-24 Intelligent 24-channel temperature Recorder 24-channel temperature Recorder Linear dispersion instrument
$ 1159.00 -
BANTE TP-100K temperature probe
$ 102.00 -
HANNA HI93552R Dual Channel Dual Range Data Type, Wide Range Temperature Meter
$ 637.00
Overview
*K/J type thermal coupling line selects dual group inputs.
*Users can choose between °C or °F temperature Unit display.
*Record past maximums, minimums, and their incidental times.
*Average, Relative Reading, Reading Recovery, and Reading Retention functions.
*Time and relative readings are set.
*The Reading Range of the Hi/Lo alarm beep and the Hi/Lo reading recovery function can be set.
* With USB communication interface, it can be connected to the computer and export data.
Product display diagram




Where to use digital thermometers
Greenhouses, offices, laboratories, environmental research, climate monitoring, art galleries, department stores, companies, factories
Precautions for the use of digital thermometers
1. If the battery is insufficient, please replace the battery to maintain the accuracy of the test.
2. When the thermometer is not used for a long time, please remove the battery from the thermometer and avoid storing it in a high temperature place.
3. Regularly use a soft damp cloth dipped in neutral detergent to gently wipe the shell, not use an abrasive cloth or solvent with soluble ability to wipe.
4. Repeatedly bending the thermocouple line will break it. Avoiding bending thermocouple wires, especially near corners, can extend the life of thermocouple wires.
TASI TASI-605A Thermocouple ThermometerSpecifications
| LIST | VALUE |
|---|---|
| Temperature Measurement Range | K:-200~1370℃;J:-200~1050℃ |
| Number of channels | 2 channel |
| Accuracy | +/- (0.05% reading + 0.3 ℃) at -50 ℃~ 1370 ℃ < br > +/- ( 0.05% reading + 0.7 ℃) at -50 ℃~ -200 ℃ < br > +/- ( 0.05% reading + 0.6 ° F) at -58 ° F~ 2498 ° F < br > +/- ( 0.05% reading + 1.4 ° F) at -5 ° F~ -328 ° F |
| Resolution | 0.1 |
| Low battery Voltage display | When the battery Voltage is lower than the operating Voltage ,“+ - ” display |
| Sampling rate | 1 time/s |
| Accuracy test environment | 23 ℃ +/- 5 ℃, Relative Humidity < 75% R.H. |
| Power Supply | Four 1.5V AA batteries |
| Environmental temperature | 0~50℃ |
| Storage environment | -20~60℃,0~70%R.H. |
| Dimensions | 160*83*38mm |
| Weight | About 270 grams (including batteries) |
| Accessories | Manual, Thermocouple cable, battery, USB cable 12V DC power converter (optional) |
| Allowable Relative Humidity | <80%R.H. |
TASI TASI-605A Thermocouple Thermometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Thermocouple thermometer purchase points
- Linear dispersion test in high temperature heat treatment
- How to determine the softening point and softening time of coating powder?
- Introduction to the calibration method of thermocouple
- Detection of softening temperature of coating powder
- Thermocouple measurement principle and characteristics
- Preparation of Fire-retardant coating of bromocarbon alkyd resin cable
- Thermal resistance measurement principle and type introduction


TASI-605A