LANDTEK ATP-100E ATP fluorescent bacteria Detector, high-sensitivity RLU detection
Special sealing material is used to improve light protection, and the detection accuracy reaches 1X10 ^ (-16) mol ATP. The integrated box design is easy to carry, and the bottom detection design ensures data Stability.
LANDTEK-
CHINA NBC-QMQ85 Pneumatic die-cutting machine, battery pole die-cutting
$ 2421.00 -
XINGHUO ZTT-930M protruding road sign abrasion performance Tester
$ 756.00 -
DUBAN DB22-FPM42K Stroboscope 50~42000 FPM
$ 377.00 -
CEM DT-9810 Digital Clamp Meter AC Current 200A CAT III 600V
$ 132.00 -
China NBC-9012 Battery Thermal Shock Test Chamber, Battery Thermal Shock test, capacity 64L
$ 2074.00
Introduction
The ATP bioluminescence Detector uses biochemiluminescence technology to change the invisible ATP concentration into visible light output, thereby indirectly displaying the number of microorganisms with quantitative results. The value is between 0 and 9999, expressed in relative light units RLUs.
Features
This ATP rapid Detector adopts special sealing material to improve light resistance, and the detection result is more accurate and stable.
The interface is simple and easy to operate.
Bottom detection is not affected by the angle of the instrument being held or placed, the detection data is not disturbed, and the result is more stable.
Integrated box design, convenient to carry when traveling.
A significantly low background value is more conducive to the detection of trace ATP, with good reproducibility, providing users with more reliable and accurate data
Application
Food, medicine and hygiene, medicine, daily chemicals, papermaking, industrial water treatment, national defense and environmental protection, water administration, customs entry-exit quarantine and others, law enforcement agencies and other industries.
Detection reference standard
Less than 30 qualified: between 30-100; greater than 100 unqualified.
LANDTEK ATP-100E ATP fluorescent bacteria DetectorSpecifications
| LIST | VALUE |
|---|---|
| Detection Accuracy | 1X10 ^ (-16) mol ATP (high sensitivity type) |
| detection lower limit | ≤1.0 CFU/ml |
| coliform | ≥ 1 × 10 ^ (-6) CFU |
| Detection time | 1 second - 60 seconds |
| Detect interference | +/- 2% or +/- 2 RLUs |
| background value | ≤2RLU |
| checkout mode | RLU or coliform screening |
| The number of limit values can be set | More than 1000 |
| Storage size | More than 3000 |
| Test result | USB interface, the result can be transferred to the PC |
| Instrument size | 199mm×76mm×37mm(W×H×D) |
| Instrument Weight | 265G (including battery) |
| Operating temperature range | 0 ℃ to 40 ℃ |
| Relative Humidity range | 20﹪-85﹪ |
| continuous reading | 600 pieces |
| battery | 2 AA batteries |
LANDTEK ATP-100E ATP fluorescent bacteria Detector Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- CM-8822 Landtek Coating Thickness Gauge
- Comparison table of each model of LANDTEK Thickness Gauge [Selection Guide]


ATP-100E
ATP-100