FANGZHOU PHS-3F + acidity meter pH value Tester
Instrument level 0.01, multiparameter measurement, pH, mV, RelmV, ORP, T value, with self-diagnostic function, judge the working state of the host and electrode performance, the chassis shell is IP54 Protection level
FZchina-
KEDIDA CT-6023 Pen type acidity meter with built-in electrode PH Range: 0.00~14.00PH
$ 114.00 -
DDKSIC PH10 Color Screen Portable pH Meter pH/mV (ORP electrode optional)/℃
$ 462.00 -
Qiwei PH-220B Pen Acidity Meter (Backlit)
$ 103.00 -
LEICI T-818-B-4F temperature electrode small four core air plug (waterproof type)
$ 125.00 -
FANGZHOU FZ-241-6 Semi-micro PH electrode for testtube and small volume sample testing
$ 285.00
Features
The main function
Large screen true color TFT LCD display, chart display, menu navigation operation
Multi-parameter measurement, pH, mV, Relmv, ORP, T value
2 resolutions available: 0.01pH/0.1pH 0.1mV/1mV
Equipotential function to meet different zero potential electrode applications
The chassis shell is IP54 protection grade
Intelligent detection
Intelligent operating system, with functions such as electrode management, calibration management, data management and user management
10 sample ID numbers, 10 personnel ID numbers, with GLP setting and query functions, truly realizing GLP function management
Automatically identify 20 kinds of pH standard solutions in 4 groups of GB, Europe, Merck and DIN, one-click calibration, up to 5 points calibration
The instrument automatically identifies and calibrates, and the graph displays the calibration curve and calibration information (calibration points, calibration date and time, solution stability and slope to directly express pH electrode status)
ATC automatic recognition, automatic/manual temperature compensation
Five measurement modes: real-time, scheduled, automatic fast, automatic medium speed, automatic slow speed measurement
With self-diagnosis function, it can judge the working status of the host and electrode performance
Dual display of clock and date, showing current time and providing time reference for digital recording function
Timing storage time in interval: (0-3600) seconds
Data management and traceability
Complying with GLP specifications, it supports 10,000 groups of data storage, allowing users to print measurement results directly or send data to a computer for data management: the instrument can send stored data to computer acquisition software, and can export Excel files, Notepad files, etc. , convenient for users to perform operations such as archiving, statistics, analysis, comparison, and saving of measurement data.
The RS232 serial port provides two application modes: (1) Connect to a micro printer to print report results (2) Send data to the computer for data statistics
FZchina PHS-3F+ Acidity meterSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | 0.01 level |
| PH range | -5.00~20.00pH |
| pH resolution | 0.01pH/0.1pH (adjustable) |
| pH intrinsic error | ±0.01pH |
| pH Repeatability | ±0.01 pH |
| pH Calibration Point | 1/2/3/4/5 point calibration possible |
| pH buffer | JJG119 (China), METTLER TOLEDO (Europe), Merck (Germany), DIN19267 (Germany) 4 groups of 20 standard solutions |
| Measurement range | -5~135.0℃ |
| Temperature Resolution | 0.1℃ |
| Temperature intrinsic error | ±0.2℃ |
| Temperature compensation range | (-20.0~135.0) ℃ (automatic/manual) |
| Input Impedance | ≥1×10^12Ω |
| input/output | Sensors interface: electrode interface, temperature interface Communication interface: RS232 |
| Power Supply | Universal Power Supply (DC9V 500mA, internal positive and external negative) |
| GLP standard | In line with GLP standards, 10 sample IDs and 10 personnel IDs |
| mV/RelmV/ORP Measurement range | (-2000.0~2000.0)mV |
| mV/RelmV/ORP resolution | 0.1mV/1 mV (adjustable) |
| mV/RelmV/ORP intrinsic error | +/- 0.1% FS or +/- 0.2mV |
| mV/RelmV/ORP Calibration Points | Reference potential can be calibrated at 1 point |
FZchina PHS-3F+ Acidity meter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


PHS-3F+