JFL QXD 0-150 double-channel Grindometer 10 μm Graduation
The QXD 0~150μm Grindometer produced by JFL has 2 grooves, the maximum fineness range is 150μm, and the sub-scale is 10μm. The scraper Hardness Gauge is made of cemented carbide steel, which is resistant to abrasion. QXD 0-150 is used to measure the particle fineness in Paints and paint slurry.
JFL-
Pushen 0-15um double-channel Fineness gauge 0~15μm
$ 214.00 -
Germany Erichsen 232 fineness gauge scraper 100μm Fineness gauge colorants/pigment fineness detection
$ 817.00 -
JINGKELIAN QXP 0-25μm ISO single-channe Fineness of Ground Gauge with Third Party Measurement Certificate
$ 220.00 -
TQCsheen VF2142 wide-channel Fineness gauge Range 0~5000μm
$ 1698.00 -
TQC VF2118 double-channel fineness grindometer 0-250 µm with calibrated certificate
$ 1247.00
Introduction
Jinfulun QXD 0-25/50/100/150 Fineness Meter is a QXD double-slot fineness scraper meter for detecting particle fineness . It uses hard alloy steel with good wear resistance and hardness, which is not easy to wear. The QXD Fineness Meter is produced in strict accordance with the requirements of the "Scraper Fineness Meter" of the Ministry of Chemical Industry's special measuring instrument calibration regulations, and meets the standards of GB/T1724-93, GB/T13217.3-91.
The measuring ranges of the QXD 0-25/50/100/150 double-slot fineness scraper gauge are 0-25μm, 0-50μm, 0-100μm, and 0-150μm respectively.
Applications
QXD 0-25/50/100/150 double-slot fineness scraper meter is used to measure the fineness of pigments and impurities in paints and paint slurries. It is used to measure the fineness of dispersed products during production, storage and application. Test and control product quality.
product material
QXD 0-25/50/100/150 double groove fineness scraper gauge is made of carbide steel.
Product actual pictures


JFL QXD 0-150 Grindometer (double-channel)Specifications
| LIST | VALUE |
|---|---|
| Scraper type | double-channel |
| Number of grooves | 2 |
| range | 0~150μm |
| Scale unit | μm |
| scraper material | Carbide steel |
| Scraper size | 155*50*13mm |
| Groove size | 13*120mm |
| Drawdown blade size | 68*40*6.5mm |
| Applicable standards | GB/T 1724-93、GB/T 13217.3-91 |
| Net Weight | 0.9kg |
| Graduation | 10μm |
JFL QXD 0-150 Grindometer (double-channel) Packing list
Fineness meter x1, doctor blade x2, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the gloss meters that meet the GB/T9966 standard?
- What are the models of stone gloss meter? What is the difference?
- These gloss meters can be used in paper inspection, understand!
- How to choose the right model for Jinfulun JFL gloss meter?
- Jinfulun JFL-B60 Glossiness Meter instruction manual
- Study on uncertainty analysis of Moisture meter measurement results by drying method
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveASTM D1316-2020
- ActiveJJG 905-2010
- ActiveASTM D333-2021
- ActiveISO 1524-2020
- AbolishGB 12441-2005
- AbolishGB/T 13217.3-2008
- ReplacedQB/T 2025-1994
- ReplacedASTM D1210-1996
- ActiveJC/T 423-1991
- ActiveGB/T 17459-1998
- ActiveGB/T 5211.17-1988
- AbolishJJG 905-1996
- AbolishJB/T 9385-1999
- AbolishGB/T 13217.3-1991
- AbolishGB/T 1724-1979


QXD 0-150