JFL QXD 0-100 double-channel Grindometer 10 μm Graduation
The QXD 0~100μm Grindometer produced by JFL has two grooves, the maximum fineness range is 100μm, and the sub-scale is 10μm. The scraper Hardness Gauge is made of carbide steel, which is resistant to abrasion.
JFL-
JINGKELIAN QXP 0-100um double-channel Fineness of Ground Gauge with Third Party Measurement Certificate
$ 245.00 -
Pushen 0-15um single-channe small Fineness gauge (single-channe) detects the Fineness of Coatings, inks and other particles
$ 192.00 -
TQC VF2121 wide-channel Grindometer 0~25μm with calibrated certificate
$ 1193.00 -
MODERNER QXD-25 wide-channel Fineness gauge
Login -
JINGKELIAN QXP 0-50 single-channe Fineness of Ground Gauge Fineness gauge 0~50μm/5μm
$ 148.00
Introduction
Jinfulun QXD 0-25/50/100/150 Fineness Meter is a QXD double-slot fineness scraper meter for detecting particle fineness . It uses hard alloy steel with good wear resistance and hardness, which is not easy to wear. The QXD Fineness Meter is produced in strict accordance with the requirements of the "Scraper Fineness Meter" of the Ministry of Chemical Industry's special measuring instrument calibration regulations, and meets the standards of GB/T1724-93, GB/T13217.3-91.
The measuring ranges of the QXD 0-25/50/100/150 double-slot fineness scraper gauge are 0-25μm, 0-50μm, 0-100μm, and 0-150μm respectively.
Applications
QXD 0-25/50/100/150 double-slot fineness scraper meter is used to measure the fineness of pigments and impurities in paints and paint slurries. It is used to measure the fineness of dispersed products during production, storage and application. Test and control product quality.
product material
QXD 0-25/50/100/150 double groove fineness scraper gauge is made of carbide steel.
Product actual pictures


JFL QXD 0-100 Grindometer (double-channel)Specifications
| LIST | VALUE |
|---|---|
| Scraper type | double-channel |
| Number of grooves | 2 |
| range | 0~100μm |
| Scale unit | μm |
| scraper material | Carbide steel |
| Scraper size | 155*50*13mm |
| Groove size | 13*120mm |
| Drawdown blade size | 68*40*6.5mm |
| Applicable standards | GB/T 1724-93、GB/T 13217.3-91 |
| Net Weight | 0.9kg |
| Graduation | 10μm |
JFL QXD 0-100 Grindometer (double-channel) Packing list
Fineness meter x1, doctor blade x2, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the gloss meters that meet the GB/T9966 standard?
- What are the models of stone gloss meter? What is the difference?
- These gloss meters can be used in paper inspection, understand!
- How to choose the right model for Jinfulun JFL gloss meter?
- Jinfulun JFL-B60 Glossiness Meter instruction manual
- Study on uncertainty analysis of Moisture meter measurement results by drying method
- ActiveJTJ 275-2000
- ActiveJT/T 821.4-2011
- ActiveJT/T 821.3-2011
- ActiveJT/T 821.2-2011
- ActiveJT/T 821.1-2011
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveGB/T 1724-2019
- ActiveASTM D1316-2020
- ActiveJJG 905-2010
- ActiveASTM D333-2021
- ActiveISO 1524-2020
- AbolishGB/T 13217.3-2008
- AbolishGB/T 13217.5-2008
- ReplacedQB/T 2025-1994
- ActiveGB/T 14616-2008
- ActiveGB/T 21867.2-2008
- AbolishGB/T 13217.5-2008
- ActiveGB/T 21990-2008
- ReplacedASTM D1210-1996


QXD 0-100