TRUIT TR 5502/1200 Double-sided wet-film gauge WFT gauge comb type 50~1200μm
2 working faces, range 50~1200μm, Graduation 50μm, corrosion resistant stainless steel, in line with GB/T 13452, ASTM D4414, ISO2808 standards.
TRUIT-
TRUIT TR 5501/200 Single-sided wet-film thickness caliper 20~200μm
$ 99.00 -
TQC VF2255 Wet Film Wheel Thickness Wheel Thickness Gauge 0~100μm
$ 881.00 -
TQC SP4000 hexagonal WFT gauge, range: 20-370 microns, six-sided Wet film instrument
$ 215.00 -
TRUIT TR 5508/25 WFT gauge Range 0~25μm
$ 184.00 -
TRUIT TR 5501/950 single-sided wet film 500~950μm
$ 99.00
Introduction
A wet Film Thickness Gauge is a tool used to measure the wet film thickness of paint, also known as a wet Film Thickness Gauge or a wet film thickness caliper. The Wet Film Thickness Gauge is a simple and practical tool widely used in the fields of paint application, quality control and paint thickness measurement. It can help monitor the quality and consistency of paint application to ensure that the thickness of the paint is as expected.
The thickness measurement range of TR 5502/1200 double-sided wet film gauge is 25~3000μm, and the division value is 50μm.
Standards
Designed in accordance with GB/T 13452, ASTM D4414 and ISO2808 standards.
product structure
A comb gauge is a flat plate of corrosion-resistant stainless steel with a series of teeth lining its edges. The datum teeth at the corners of the plate form a baseline along which the internal teeth and datum teeth form a progressive series of gaps. Each internal tooth is marked with a given gap depth value.
When using a wet film thickness gage, first place the gage tip lightly on the wet paint surface, making sure that the paint fully contacts the scale line side of the gage tip. Then, read the position of the scale line in contact with the paint on the dial to get the thickness value of the wet paint.
Series
| model | name | working face | Range | Division value |
| TR 5501/100 | Single-sided wet film | 1 | 10~100μm | 10μm |
| TR 5501/150 | Single-sided wet film | 1 | 15~150μm | 15μm |
| TR 5501/200 | Single-sided wet film | 1 | 20~200μm | 20μm |
| TR 5501/700 | Single-sided wet film | 1 | 250~700μm | 50μm |
| TR 5501/950 | Single-sided wet film | 1 | 500~950μm | 50μm |
| TR 5502/120 | Double-sided wet film | 2 | 5~120μm | 5μm |
| TR 5502/600 | Double-sided wet film | 2 | 25~600μm | 25μm |
| TR 5502/1200 | Double-sided wet film | 2 | 50~1200μm | 50μm |
| TR 5502/3000 | Six-sided wet film | 6 | 25~3000μm | 25~200μm |
TRUIT TR 5502/1200 Single-sided wet filmSpecifications
| LIST | VALUE |
|---|---|
| working surface | 1 |
| Range | 50~1200μm |
| Graduation | 50μm |
TRUIT TR 5502/1200 Single-sided wet film Packing list
Wet film X1, certificate X1, manual X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 16311-2024
- ActiveJJF 1484-2014
- ActiveCB/T 3718-2016
- ActiveISO 2808-2019
- ActiveASTM D4414-95-2020
- AbolishISO 2808-2007
- ActiveGB/T 13452.2-2008


TR 5502/1200
TR 5502/120
TR 5502/600