YONGLIDA QNB-5 ISO flow Viscosity Cup 5mm aperture Measurement range 91~ 326cSt
Viscosity range 91~ 326cSt, flow hole diameter 5mm, cup body material aluminum alloy, filter material stainless steel, Applicable standards ISO 2431, GB/T 6753.4.
YongLiDa-
Ander ZAHN Cup, Stainless Steel, Bore 1.93mm
$ 133.00 -
Japan TOYO TOYO 4 #Viscosity Cup Zahn Viscosity Cup Zahn Cup zahn second measuring cup
$ 183.00 -
TRUIT TR 1004/4 French standard Viscosity Cup aperture φ4.0mm
$ 125.00 -
Rhopoint RL-A-FC-AFNOR/8 AFNOR Flow Cup (8mm) NF T30-014
$ 406.00 -
CSB Zahn Cup YONGLIDA No. 2 Zahn Cup
$ 127.00
QNB ISO Outflow Viscosity Cup Overview
Yonglida QNB ISO outflow Viscosity Cup is a desktop ISO outFlow Cup designed according to ISO2431 and GB/T6753 standards. It is used to measure the outflow time of Newtonian or near-Newtonian liquids, and the time is between 30 and 100s. QNB ISO outflow Viscosity Cups are available in five models: QNB-3, QNB-4, QNB-5, QNB-6, QNB-8, the diameters of the mouth of the cups are 3mm, 4mm, 5mm, 6mm, 8mm respectively, and the cup body is made of aluminum alloy , The outflow nozzle is stainless steel.
Specifications
| model | outflow aperture | Measuring range |
| QNB-ISO-3 | 3mm | 7~42cSt |
| QNB-ISO-4 | 4mm | 34~135cSt |
| QNB-ISO-5 | 5mm | 91~326cSt |
| QNB-ISO-6 | 6mm | 188~684cSt |
| QNB-ISO-8 | 8mm | 600~2000cSt |
| Other parameters | ||
| material | Cup body: aluminum alloy; spout: stainless steel | |
| application standard | ISO 2431, GB/T 6753.4 | |
QNB ISO outflow Viscosity Cup display


QNB ISO Outflow Viscosity Cup Application Standard
ISO 2431 "Paints and varnishes - Determination of outflow time by outFlow Cup", GB/T 6753.4 "Determination of paint outflow time - ISO Flow Cup method"
YongLiDa QNB-ISO-5 ISO Flow Cup (single cup)Specifications
| LIST | VALUE |
|---|---|
| Viscosity range | 91~326cSt |
| Flow hole diameter | 5mm |
| Cup body material | aluminum alloy |
| Filter material | stainless steel |
| Applicable standard | ISO 2431、GB/T 6753.4 |
| Certificate | without |
YongLiDa QNB-ISO-5 ISO Flow Cup (single cup) Packing list
Flow cup X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to measure Coating viscosity with ISO cup
- Coating viscosity determination by Flow Cup method
- Decryption paints original juice viscosity cup, principle, application and selection
- ActiveGB/T 33374-2016
- ActiveGB/T 1727-2021
- ActiveASTM D5125-2020
- ActiveISO 2431-2016
- ActiveJJG 743-2018
- ActiveASTM D5125-2020
- AbolishISO 2431-2019
- ActiveGB/T 6753.6-1986
- ActiveHG/T 2003-1991
- ActiveGB/T 1981.3-2009
- ActiveGB/T 22235-2008
- ReplacedGB 1727-1992
- ActiveGB/T 6753.4-1998


QNB-ISO-5
QNB-ISO-5