Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Drying Oven> Kenton> Kenton KH-45A + independent temperature limiter Digital electric air blowing dryer

      Kenton KH-45A digital electric air blowing dryer 250 ℃/70L with independent temperature limiter

      Standard independent temperature limiter, temperature control up to 250 ℃, intelligent PID control digital display, galvanized sheet liner, with timing function, studio size 450 × 450 × 350mm, over-temperature alarm.

      VS
      Genuinegoods
      • Kenton KH-45A + independent temperature limiter Digital electric air blowing dryerOverview

      • Specifications
      • Comments
      • FAQs
      KH-45A + independent temperature limiter
      Digital electric air blowing dryer
      • Kenton KH-45A digital electric air blowing dryer 250 ℃/70L with independent temperature limiter
      • Kenton KH-45A digital electric air blowing dryer 250 ℃/70L with independent temperature limiter Figure 1
      • Kenton KH-45A digital electric air blowing dryer 250 ℃/70L with independent temperature limiter Figure 2
      Standard independent temperature limiter, temperature control up to 250 ℃, intelligent PID control digital display, galvanized sheet liner, with timing function, studio size 450 × 450 × 350mm, over-temperature alarm.


      Kangheng KH-45A+ Independent Temperature Limiter Digital Display Electric Forced Air Drying Oven Details Figure 1

      Kangheng KH-45A+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 2

      Kangheng KH-45A+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 3

      Kangheng KH-45A+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 4

      Kangheng KH-45A+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 5

      Recommendations

      Routine experiments and tests are recommended, cost-effective. For more expensive samples, it is recommended to install an independent temperature limit controller.

      Application

      It is used for drying, heat treatment, and heating in various medical and health, medicine, biology, agriculture, scientific research and other departments, but it is not suitable for volatile, flammable, explosive and other items, so as not to cause explosion.

      warn! It is strictly forbidden to put flammable, explosive and volatile items into the box for heating and drying. For high-value materials, it is better to install an independent temperature limiter to set the upper limit of the maximum temperature. Double insurance ensures that the materials will not fail due to the electronic components of the box. Excessive heating can lead to damage.

      Structural features

      1. Using microcomputer intelligent PID control technology, the system has temperature control, timing, and over-temperature alarm functions;

      2. The external hot air circulation system is composed of low-noise fans and air ducts. Reasonable air duct and circulation system to stabilize the temperature in the working room;

      3. The shell is made of good cold-rolled steel plate treated by electrostatic spraying, the overall design is beautiful and novel, and it has a large Viewing Angle observation window;

      4. The liner is divided into mirror stainless steel and galvanized steel, and the semi-curved corners are easy to clean;

      5. The distance between shelves and the number of shelves in the studio can be adjusted to facilitate access to samples of different specifications;

      6. Use high-temperature resistant silica gel as the sealing door, and high-temperature heating tube as the heating element to ensure safety and longer service life;

      7. Ergonomic buckle handle, easy to operate, and ensure tightness.

      Optional :

      1. Independent temperature limit controller;

      2. Intelligent program temperature controller.

      Kangheng KH-45A+ independent temperature limiter digital display electric Forced Air Drying Oven details Figure 6

      Models

      Digital display electric Forced Air Drying Oven (galvanized liner, with timer)

      model

      Studio size (mm)

      Power (KW)

      KH-25A

      250×250×265

      0.5

      KH-30A

      250×250×265

      0.5

      KH-35A

      350×350×350

      1

      KH-45A

      450×450×350

      1.2

      KH-55A

      550×550×450

      1.6

      KH-75A

      750×600×500

      2.5

      Digital display electric Forced Air Drying Oven (stainless steel liner, with timing)

      KH-25AS

      250×250×265

      0.5

      KH-30AS

      250×250×265

      0.5

      KH-35AS

      350×350×350

      1

      KH-45AS

      450×450×350

      1.2

      KH-55AS

      550×550×450

      1.6

      KH-75AS

      750×600×500

      2.5

      All stainless steel digital display Forced Air Drying Oven (galvanized liner, with timer)

      KH-35T

      350×350×350

      1

      KH-45T

      450×450×350

      1.2

      KH-55T

      550×550×450

      1.6

      KH-75T            

      750×600×500

      2.5

      VS

      Kenton KH-45A + independent temperature limiter Digital electric air blowing dryerSpecifications

      LIST VALUE
      Temperature range RT+5~250
      Temperature Fluctuation ±1%
      Accuracy ±0.5℃
      Volume 70L
      Interior size 450*450*350mm
      Chamber material Galvanized steel sheet
      Enclosure Material Cold rolled steel plate surface electrostatic spraying
      Timer 0~999min
      Viewing Window Yes.
      Power 220V
      Input Power 1.2Kw
      Dimensions 630*740*550mm

      Kenton KH-45A + independent temperature limiter Digital electric air blowing dryer Packing list

      host X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      Kenton
      Kenton KH-45A digital electric air blowing dryer 250 ℃/70L with independent temperature limiter
      Service
      Focus on online sales of Lab Testing Instruments