      Home> Rotational Viscometer> NiRun> NiRun NDJ-5S + Ultra Low Viscosity Adapter Digital Viscometer

      NIRUN NDJ-5S Ultra Low Viscometer with Ultra Low Viscosity Adapter 0 #Rotor

      Measurement range 1~ 100000mPa · s, rotor specification 0 #(ultra low viscosity adapter), 1 #, 2 #, 3 #, 4 #, Rotor speed 6/12/30/60rpm, Repeatability +/- 0.2% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage AC 100-240V, Interface RS232, temperature sensor RTD temperature sensor.

      Brand
      SKU: NB043708
      China NiRun
      Stock
      Loading…
      Price
      $ 1036.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • NiRun NDJ-5S + Ultra Low Viscosity Adapter Digital ViscometerOverview

        • Specifications
        • Comments
        • FAQs
        NDJ-5S + Ultra Low Viscosity Adapter
        Digital Viscometer
        • NIRUN NDJ-5S Ultra Low Viscometer with Ultra Low Viscosity Adapter 0 #Rotor
        • NIRUN NDJ-5S Ultra Low Viscometer with Ultra Low Viscosity Adapter 0 #Rotor Figure 1
        Measurement range 1~ 100000mPa · s, rotor specification 0 #(ultra low viscosity adapter), 1 #, 2 #, 3 #, 4 #, Rotor speed 6/12/30/60rpm, Repeatability +/- 0.2% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage AC 100-240V, Interface RS232, temperature sensor RTD temperature sensor.

        Rotational viscometers are often used to measure the viscosity of liquids, but for ultra-low viscosity liquids, an adapter may be required to ensure accurate measurement.

        Technical Features

        The improved 16-bit microcomputer processor is the core, and the anti-interference performance is greatly improved

        Digital LCD 4-line digital display with blue backlight

        Stepper motor direct drive, no gear, accurate speed

        Standard RTD temperature probe, RS232 interface

        Displays the maximum measurable viscosity value of the rotor at the current rotational speed.

        Measurement timing function, print interval setting, viscosity unit selection

        Viscosity values show continuous changes

        There is an alarm sound prompt beyond the measurement range

        Computer full scale linear correction

        AC power adapter 100V-240V, good anti-interference

        Optional

        Special viscosity measurement constant temperature Water Tank

        Microprinter, Glass Circulation Cup

        Application

        Ink, ink, glue, latex, solvent-based adhesives, biochemical preparations, polymer solutions, petroleum, paints and coatings, solvents, lithium battery paddles, cosmetics, milk products, medicines, fruit juices, petroleum, solvents, etc.


        VS

        NiRun NDJ-5S + Ultra Low Viscosity Adapter Digital ViscometerSpecifications

        LIST VALUE
        Display LCD with blue backlight 4-line digital display
        Measurement range 1~100000mPa·s
        Rotor Specifications 0#、1#、2#、3#、4#
        Rotor speed 6/12/30/60rpm
        Repeatability ±0.2%F.S
        Measurement Accuracy ±1%F.S
        Power AC 100-240V
        Interface RS232
        Temperature transducer RTD temperature probe

        NiRun NDJ-5S + Ultra Low Viscosity Adapter Digital Viscometer Packing list

        host x1, ultra-low viscosity adapter, one rotor each for 1 #, 2 #, 3 #, and 4 #, manual x1, warranty card x1.

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Measurement of ultra-low viscosity ink or glue, what Viscometer?
        [A]
        Recommended NIRUN NDJ-5S with ultra low viscosity adapter, because it is designed for 1~ 100000mPa · s range, stepper motor direct drive to ensure accurate ultra low viscosity measurement, suitable for ink, glue and other liquid flowability.
        [Q]
        The laboratory needs to measure the viscosity of lithium battery slurry. Which instrument is better to choose?
        [A]
        It is recommended to use NIRUN NDJ-5S + ultra-low viscosity adapter, which has RTD temperature sensor and a variety of rotors, can accurately control Measurement conditions, 6~ 60rpm multi-gear Rotation speed can match different shear rates of slurry, Repeatability up to +/- 0.2%, to ensure reliable data.
        [Q]
        Measure the viscosity of juice or milk, how to choose the function?
        [A]
        Choose NDJ-5S with ultra-low viscosity adapter on the line, it has timing measurement and alarm function to prevent operation errors, and the LCD screen can display viscosity changes in real time, with Thermostatic water bath Accessories can also control the temperature, to ensure that such as juice, milk and other foods viscosity measurement stability.
        +NiRun NDJ-5S + Ultra Low Viscosity Adapter Digital Viscometer Big data
          +NiRun NDJ-5S + Ultra Low Viscosity Adapter Digital ViscometerSimilar products
          +NiRun NDJ-5S + Ultra Low Viscosity Adapter Digital ViscometerKnowledge
          +NiRun NDJ-5S + Ultra Low Viscosity Adapter Digital ViscometerStandard
          +Navigation
          NiRun
          NIRUN NDJ-5S Ultra Low Viscometer with Ultra Low Viscosity Adapter 0 #Rotor
          Service
          Focus on online sales of Lab Testing Instruments