CHINA Programmable Humidity Chamber -20~150 ℃/50L
LCD touch screen operation, volume 50L, temperature control -20 ℃~ 150 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, 304 stainless steel outer box, programmable control, suitable for magnet, coating, lithium battery testing.
HuiTai-
YIHENG BPS-100CL Humidity Chamber -10~100 ℃/100L
$ 3497.00 -
ZKHS GDJS-800C high-low temperature Humidity Cyclic Chamber -40~150 ℃/800L
$ 12072.00 -
Haiyoda Vulcanized rubber constant temperature and Humidity Test Chamber QT-E702-1000B40 -40 ℃/408L
$ 4486.00 -
YIHENG BDW-86L490 ultra-low temperature freezer 490L/-50~ -86 ℃
$ 6261.00 -
Aipei AP-HX-225D Programmable high and low temperature heating and humidity alternating box 225L/-60 ℃
$ 6584.00











Introduction
The function of the Test Chamber is to provide a test environment such as constant high-low temperature and humidity, alternating high-low temperature and humidity; including refrigeration system, heating system, humidification/waterway system, air duct system, control system, system protection device, etc.
Constant temperature and humidity testing machine, also known as environmental testing machine, can accurately simulate complex natural environments such as low temperature, high temperature, high temperature and high humidity, low temperature and low humidity, and is suitable for electronics, electrical appliances, batteries, plastics, food, paper products, vehicles, metals, chemical, building materials, research institutes, inspection and quarantine bureaus, universities and other industry units for quality control testing.
Test box
1. Structural form
Integral structure, that is, the test box, refrigeration system, heating/humidification system, air conditioning system, electrical control cabinet, and refrigeration unit are integrated. The refrigeration unit is located at the bottom of the box, and the electrical control part is placed on the side of the test box. Easy to operate.
2. Box
A) In the interlayer of the air duct at one end of the studio, heating/humidifier, refrigeration evaporator, blast motor, fan blade and other devices are distributed; b) The Test Chamber studio is made of 1mm thick SUS304 stainless steel plate, and enclosure is made of 1mm thick stainless steel.
Standards
GB11158, GB10589-89, GB10592-89, GB/T10586-89, GB/T2423.1-2001, GB/T2423.2-2001, GB/T2423.3-93, GB/T2423.4-93, GB/T2423.22-2001, IEC60068-2-1.1990, IEC60068-2-2.1974, GJB150.3, GJB150.4, GJB150.9 and other standards.
Test chamber refrigeration system
Refrigeration principle
The refrigeration part is the main part of the cold source generated by the equipment, which provides the required cooling capacity for the cooling, low temperature and constant temperature of the equipment. According to the different test states of the equipment, the refrigeration system is automatically turned on to provide cooling capacity for the corresponding test process, so as to achieve the purpose of equipment performance indicators.
Refrigeration system components
1. Compressor: The refrigeration system is mainly a compressor. In this plan, we use a French Taikang fully enclosed compressor. 2.2. Oil separator: Whether the compressor has refrigeration oil will directly affect its life
3. Condensing evaporator: using the current Swedish "Alfa Laval" in the world
4. Vibration reduction: The compressor spring is used to reduce vibration, and the overall secondary vibration reduction of the refrigeration system;
5. Refrigeration evaporator: The evaporator is located in the interlayer of the air duct at one end of the Test Chamber, and is forced to ventilate by the blower motor
touch controller
1.LCD touch panel, screen conversation input data, temperature and humidity can be programmed at the same time:
2. It can display the curve, display the set value curve and the actual operation curve;
3. Programmable, the program group can reach 120 groups;
4. Chinese and English interface can be switched;
5. With date, time adjustment, scheduled start, shutdown function and screen lock (LOCK) function.

HuiTai NBC-LHS-50L(-20℃) Humidity chamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -20~150℃ |
| Temperature Fluctuation | ≤±0.5℃ |
| Temperature Uniformity | ≤±2℃ |
| Humidity control range | 20~98%R.H |
| Humidity Deviation | ≤ +/- 2%~ 3% R. H (above 75% R. H ); +/- 5% R. H (below 75% R. H) |
| Input Power | 3.5Kw |
| Power | 220V/±10%V 50Hz |
| Interior size | 350*400*350mm |
| Dimensions | 600*1450*870mm |
| Interior Volume | 50L |
| Cooling rate | 0.7~1℃/min |
| Heating rate | 2~3℃/min |
| Cooling rate | 3~5℃/min |
| Noise | ≤65dB |
| wind speed | 1.7~2.5m/s |
| Humidity Deviation | ≤3% |
| Heating rate | RT + → 150 ℃ │ 40min (no-load nonlinear) |
| Cooling rate | RT + → -40 ℃ │ 60min (no-load nonlinear) |
| Heating rate | 3~5℃/min |
HuiTai NBC-LHS-50L(-20℃) Humidity chamber Packing list
Complete machine X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The Critical Study of Coating Specimen State Adjustment and Test Temperature Humidity
- Principle and Application Analysis of Fluorine Resin thermostatic Box
- Analytical magnetic material programmable Humidity Chamber, principle, application and selection
- Principle, application and selection of luggage Humidity Chamber
- Principle, application and selection of programmable Humidity Chamber for die casting
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveJG/T 25-2017
- ActiveGB/T 43489-2023
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012


NBC-LHS-50L(-20℃)