      Home> Fineness Gauge> Moderner> Moderner QXD-25 (single-channe) Single-channe Fineness gauge

      MODERNER QXD-25 single-channe Fineness gauge stainless steel material 0~25μm range

      Single-channe, range 0~25μm, Graduation 1.25μm, stainless steel, scale unit μm.

      Brand
      SKU: NB004389
      Boutique China Moderner
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Moderner QXD-25 (single-channe) Single-channe Fineness gaugeOverview

        • Specifications
        • Comments
        • FAQs
        QXD-25 (single-channe)
        Single-channe Fineness gauge
        • MODERNER QXD-25 single-channe Fineness gauge stainless steel material 0~25μm range
        • MODERNER QXD-25 single-channe Fineness gauge stainless steel material 0~25μm range Figure 1
        • MODERNER QXD-25 single-channe Fineness gauge stainless steel material 0~25μm range Figure 2
        Single-channe, range 0~25μm, Graduation 1.25μm, stainless steel, scale unit μm.

        QXD-25 single groove Fineness of Grind Gauge is a small stainless steel single groove Fineness of Grind Gauge for MODERNER. QXD-25 single-slot Fineness of Grind Gauge is suitable for particle fineness detection in coatings, pigments, printing inks and other industries. It is a manual fineness detection.

        Application

        The Applications of QXD single-slot Fineness of Grind Gauge include paint, plastic, pigment, printing ink, paper, ceramics, medicine, food, etc. 

        real shot

        QXD-25 single groove Fineness of Grind Gauge standard

        QXD-25 single groove Fineness of Grind Gauge material

        QXD-25 single groove scraper fineness measuring range

        operation method

        1. Before using the QXD-25 single-slot Fineness of Grind Gauge, soak the plate and bottom with a suitable solvent, and dry it with cotton yarn.

        2. Fully stir the sample that meets the product standard viscosity index with an ink-adjusting knife.

        3. Drop a few drops of sample solution into the deepest part of the groove of the QXD single-groove Fineness of Grind Gauge .

        4. Hold the scraper with the thumb, index finger and middle finger of both hands, and place it horizontally on the upper end of the stainless steel Grindometer, so that the scraper is perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed. The paint swatch fills the grooves without leaving excess paint on the panel.

        5. After scraping, immediately pinch the QXD single-groove Fineness of Grind Gauge horizontally (within 5 seconds) and tilt it so that the line of sight is 15-20 degrees from the groove plane, and observe the particle uniformity in the groove with light. and the scale value at the exposed place, the reading value is the fineness of the measured object.

        Maintenance

        (1) Clean it immediately after use and apply vaseline to prevent the fineness gauge from rusting.

        (2) Do not scratch the surface of the QXD-25 single-slot Fineness of Grind Gauge and the scraper.

        (3) When measuring the fineness, the clear oil that meets the product standard should be adjusted first, and then measured with the QXD single-slot Fineness of Grind Gauge .

        (4) Regularly (one year) check the knife edge and the straightness of the fineness gauge. If unevenness or wear of the fineness gauge is found, it needs to be calibrated by the national metrology and verification agency before it can be used.

        Specification list

        MODERNER Fineness of Grind Gauge series specification list

        Series

        SpecificationRangeDivision valueGroove sizeunit
        small single slot0-150.7512.7*140μm
        0-251.25Hegman/μm
        0-502.5
        0-1005
        0-1505μm
        small double slot0-252.5Hegman/μm
        0-502.5
        0-1005
        0-1505μm
        wide slot0-251.2525.4*127Hegman/μm
        0-502.5
        0-1005
        large wide groove0-252.550.8*127
        0-505
        0-1005
        Big double slot0-252.525.4*165Hegman/μm/NPIRI
        0-505
        0-1005
        Special double slot0-502μm
        0-25010μm


        VS

        Moderner QXD-25 (single-channe) Single-channe Fineness gaugeSpecifications

        LIST VALUE
        Scraper type Single-channe
        Number of grooves 1
        range 0 ~ 25µm
        Scale unit mm
        Scraper material stainless steel
        Scraper size 170*50*12mm
        Groove size 12.7*140mm
        Scraper material stainless steel
        Scraper size 70mm
        Graduation 1.25µm

        Moderner QXD-25 (single-channe) Single-channe Fineness gauge Packing list

        Scraper x1, scraper x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How accurate is this Fineness gauge?
        [A]
        Scale interval is 1.5um
        [Q]
        Is the scraper Fineness Meter polished?
        [A]
        Hello, no.
        [Q]
        What is the minimum scaling interval for the Scraper Fineness Meter?
        [A]
        Hello, the scale interval is 1.25 microns.
        [Q]
        Does the single-channe Fineness gauge meet the JT/T 821.1 specification?
        [A]
        Model QXD-25 single-channe Fineness gauge
        [Q]
        Can the QXD25 Fineness gauge be used to scrape pigments around 19μm?
        [A]
        Yes, the single-channe scraper fineness Measurement can scrape 0~ 25μm or less material fineness.
        Moderner
        MODERNER QXD-25 single-channe Fineness gauge stainless steel material 0~25μm range
        Service