MODERNER QXD-50 single-channe Fineness gauge range from 0 to 50 microns
Single-channe, range 0~50μm, scale unit μm, scraper material stainless steel, groove size 12.7 * 140mm, scraper material stainless steel, Graduation 2.5μm.
Moderner-
JINGKELIAN QXP 0-100um double-channel Fineness of Ground Gauge 0~100μm
$ 183.00 -
JINGKELIAN QXP 0-50S ISO Fineness of Ground Gauge with Third Party Measurement Certificate
$ 245.00 -
Germany Erichsen 232 fineness gauge scraper 100μm Fineness gauge colorants/pigment fineness detection
$ 817.00 -
TQC VF2120 wide-channel Grindometer 0~15μm with calibrated certificate
$ 1193.00 -
JINGKELIAN QXP 50-150um single-channe Fineness of Ground Gauge Fineness gauge 50~150μm/10μm
$ 148.00
MODERNER QXD-50 single channel Fineness gauge is a single groove stainless steel fineness plate with a measuring range of 0~50 microns, and the graduation value is 2.5 microns. QXD-50 single channel Fineness gauge is suitable for pigments, printing inks and other industries. Fineness detection. QXD-50 single channel Fineness gauge has two scale units of micron and Hegman.
Application
The Applications of QXD single-slot Fineness of Grind Gauge include paint, plastic, pigment, printing ink, paper, ceramics, medicine, food, etc.
real shot



operation method
1. Before using the QXD-50 single-slot fineness plate, wash the plate and the bottom with a suitable solvent, and dry it with cotton yarn.
2. Fully stir the sample that meets the product standard viscosity index with an ink-adjusting knife.
3. Drop a few drops of sample solution into the deepest part of the groove of the QXD-50 single-channel Fineness gauge .
4. Hold the scraper with the thumb, index finger and middle finger of both hands, and place it horizontally on the upper end of the stainless steel Grindometer, so that the scraper is perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed. The paint swatch fills the grooves without leaving excess paint on the panel.
5. After scraping, immediately pinch the QXD single-groove Fineness of Grind Gauge horizontally (within 5 seconds) and tilt it so that the line of sight is 15-20 degrees from the groove plane, and observe the particle uniformity in the groove with light. and the scale value at the exposed place, the reading value is the fineness of the measured object.
Maintenance
(1) Clean it immediately after use and apply vaseline to prevent the fineness gauge from rusting.
(2) Do not scratch the surface of the QXD single-slot Grindometer and the scraper.
(3) When measuring the fineness, the clear oil that meets the product standard should be adjusted first, and then measured with the QXD single-slot Fineness of Grind Gauge .
(4) Regularly (one year) check the knife edge and the straightness of the fineness gauge. If unevenness or wear of the fineness gauge is found, it needs to be calibrated by the national metrology and verification agency before it can be used.
Specification list

Series
| Specification | Range | Division value | Groove size | unit |
| small single slot | 0-15 | 0.75 | 12.7*140 | μm |
| 0-25 | 1.25 | Hegman/μm | ||
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| 0-150 | 5 | μm | ||
| small double slot | 0-25 | 2.5 | Hegman/μm | |
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| 0-150 | 5 | μm | ||
| wide slot | 0-25 | 1.25 | 25.4*127 | Hegman/μm |
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| large wide groove | 0-25 | 2.5 | 50.8*127 | |
| 0-50 | 5 | |||
| 0-100 | 5 | |||
| Big double slot | 0-25 | 2.5 | 25.4*165 | Hegman/μm/NPIRI |
| 0-50 | 5 | |||
| 0-100 | 5 | |||
| Special double slot | 0-50 | 2 | μm | |
| 0-250 | 10 | μm |
Moderner QXD-50 (single-channe) Single-channe Fineness gaugeSpecifications
| LIST | VALUE |
|---|---|
| Scraper type | Single-channe |
| Number of grooves | 1 |
| range | 0 ~ 50µm |
| Scale unit | mm |
| Scraper material | stainless steel |
| Scraper size | 170*50*12mm |
| Groove size | 12.7*140mm |
| Scraper material | stainless steel |
| Graduation | 2.5µm |
Moderner QXD-50 (single-channe) Single-channe Fineness gauge Packing list
Scraper x1, scraper x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- IncomingGB/T 17001.3-2025
- ActiveHG/T 5173-2017
- ActiveWJ 2669-2005
- ActiveGB/T 42541-2023
- ActiveGB/T 17001.6-2022
- AbolishTB/T 2260-1991
- ActiveHG/T 5370-2018
- ActiveHG/T 5367.1-2018
- ActiveHG/T 5183-2017
- ActiveHG/T 5180-2017
- ActiveHG/T 5175-2017
- ActiveHG/T 3349-2003
- ActiveJT/T 821.3-2011
- ActiveJT/T 821.1-2011
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveGB/T 1724-2019
- ActiveASTM D1316-2020
- ActiveGB/T 5211.17-1988
- ActiveJJG 905-2010


QXD-50 (single-channe)