CHINA Ford-2 #Ford Viscosity Cup, flow hole 2.53mm
The diameter of the flow hole is 2.53mm, the cup is made of aluminum alloy, the cup nozzle is made of stainless steel, and the viscosity measurement range is 25-120cst, which is suitable for Coating, paints, inks viscosity testing.
Factory-
TQC VF2049 Coating Viscosity Cup ISO Flow Cup No. 4 with VF2061 bracket
$ 800.00 -
TRUIT TR 1006/2 Portable DIN Cup φ2.0mm
$ 130.00 -
TQC VF2049 desktop 4 Viscosity Cup 4mm filter
$ 424.00 -
TQC VF2087 No. 4 Ford Viscosity Cup filter aperture 4.1mm
$ 452.00 -
TQC No. 5 Ford Ford Viscosity Cup, model VF2033, filter aperture 5.2mm
$ 452.00
Introduction
The Ford Cup is a standard test equipment for viscosity measurement of paints, coatings and similar substances, commonly used for quality control and R&D in the paint and coatings industry. The Ford cup is a Viscosity Cup used to measure the fluidity and viscosity of a liquid to determine its flow properties. According to the American Society for Testing and Materials paint and raw material standards ASTM D1200, D333, D365, the capacity is approximately 100ml.
The outflow aperture of the Ford-2# Ford cup is 2.53mm, made of aluminum alloy, and the cup mouth is made of stainless steel. The viscosity measurement range is 25-120cst. It is suitable for viscosity testing of coatings, paints, and inks.
Principle
The principle of the Ford cup is based on the relationship between outflow velocity and liquid viscosity. Under certain conditions, the liquid in the Ford cup will flow out of a fixed hole, and the time it takes to flow out is used to evaluate the viscosity of the liquid. Different models of Ford cups have different apertures and designs for measuring liquids with different viscosity ranges.
Way of working
The typical structure of a Ford cup is a conical cup with a small hole in the bottom. During the test, the cup is filled with the liquid to be tested, and then the cup is turned upside down and fixed on a stand, and the liquid flows out through the small hole. By measuring the time it takes for the liquid to flow out of a small hole, the viscosity of a liquid can be calculated.
Factory Ford-2# Ford Viscosity CupSpecifications
| LIST | VALUE |
|---|---|
| flow hole diameter | 2.53mm |
| outflow time | 40-100s |
| Applicable standards | ASTM D1200、ASTM D333、ASTM D365 |
| Viscosity range | 25-120cSt |
| Capacity | 100ml±1ml |
| Cup height | 43±0.1mm |
| Cup body material | aluminum alloy |
| Filter material | 304 stainless steel |
| Flow hole length | 10mm±0.1mm |
| Cup outer diameter | 86mm±0.1mm |
| Cup inner diameter | 50mm±0.05mm |
Factory Ford-2# Ford Viscosity Cup Packing list
Ford viscosity cup X1, test report X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Viscosity cup introduction and selection guide
- Analysis of the principle, use and application of Ford6 viscosity cup
- Measurement accuracy and efficiency of viscosity cup
- Coating viscosity determination - viscosity cup Yiwen
- Analysis of factors affecting viscosity
- ActiveASTM ASTM D1200
- ReplacedASTM
- ReplacedASTM D1200-2010
- ActiveJJG 743-2018
- ActiveASTM D333-2021
- ReplacedASTM D1200-2018


Ford-2#