MODERNER QXD-100 single-channe Fineness meter, corrosion-resistant stainless steel 0~100μm range
Single-channe, range 0~100μm, scale unit μm, scraper material stainless steel, groove size 12.7 * 140mm, scraper material stainless steel, scraper size 70mm, Graduation 5μm.
Moderner-
QXP0-150S double-channel Fineness gauge YONGLIDA QXP Fineness gauge
$ 172.00 -
TQCsheen VF2143 single-channe Grindometer Range 0~1000μm
$ 2177.00 -
JINGKELIAN QXP 0-25S ISO Fineness of Ground Gauge Fineness gauge 0~25μm/2.5μm
$ 192.00 -
TQC VF2108 single-channe grinding Grindometer 0~250μm with calibrated certificate
$ 1380.00 -
TRUIT TR 1203/050 Wide-channel Fineness meter 0~50μm
$ 187.00
MODERNER QXD-100 single-slot Fineness Meter is a single-slot Fineness of Grind Gauge made of anti-corrosion stainless steel. The fineness range of QXD-100 is 0~100 μm, and the division value is 5 microns. QXD-100 single-slot Fineness Meter has two scale units of Hegman and micron, and is designed and manufactured according to JJG (Chemical) 018-96 "Fineness of Grind Gauge" and its GB/T1724 standard.
Application
Applications include paints, plastics, pigments, printing inks, paper, ceramics, medicine, food, etc.
real shot



operation method
1. Before using the QXD-100 single-slot Fineness Meter, wash the board and bottom with a suitable solvent, and dry it with cotton yarn.
2. Fully stir the sample that meets the product standard viscosity index with an ink-adjusting knife.
3. Drop a few drops of sample solution into the deepest part of the groove of the QXD-100 single groove Fineness Meter .
4. Hold the scraper with the thumb, index finger and middle finger of both hands, and place it horizontally on the upper end of the stainless steel Grindometer, so that the scraper is perpendicular to the surface of the Grindometer, and pull the scraper from the deep part of the groove to the shallow part at an appropriate speed. The paint swatch fills the grooves without leaving excess paint on the panel.
5. After scraping, immediately pinch the QXD single-groove Fineness of Grind Gauge horizontally (within 5 seconds) and tilt it so that the line of sight is 15-20 degrees from the groove plane, and observe the particle uniformity in the groove with light. and the scale value at the exposed place, the reading value is the fineness of the measured object.
Maintenance
(1) Clean it immediately after use and apply vaseline to prevent the fineness gauge from rusting.
(2) Do not scratch the surface of the QXD single-slot Grindometer and the scraper.
(3) When measuring the fineness, the clear oil that meets the product standard should be adjusted first, and then measured with the QXD single-slot Fineness of Grind Gauge .
(4) Regularly (one year) check the knife edge and the straightness of the fineness gauge. If unevenness or wear of the fineness gauge is found, it needs to be calibrated by the national metrology and verification agency before it can be used.
Specification list

Series
| Specification | Range | Division value | Groove size | unit |
| small single slot | 0-15 | 0.75 | 12.7*140 | μm |
| 0-25 | 1.25 | Hegman/μm | ||
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| 0-150 | 5 | μm | ||
| small double slot | 0-25 | 2.5 | Hegman/μm | |
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| 0-150 | 5 | μm | ||
| wide slot | 0-25 | 1.25 | 25.4*127 | Hegman/μm |
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| large wide groove | 0-25 | 2.5 | 50.8*127 | |
| 0-50 | 5 | |||
| 0-100 | 5 | |||
| Big double slot | 0-25 | 2.5 | 25.4*165 | Hegman/μm/NPIRI |
| 0-50 | 5 | |||
| 0-100 | 5 | |||
| Special double slot | 0-50 | 2 | μm | |
| 0-250 | 10 | μm |
Moderner QXD-100 (single-channe) Single-channe Fineness gaugeSpecifications
| LIST | VALUE |
|---|---|
| Scraper type | Single-channe |
| Number of grooves | 1 |
| range | 0 ~ 100µm |
| Scale unit | mm |
| Scraper material | stainless steel |
| Scraper size | 170*50*12mm |
| Groove size | 12.7*140mm |
| Scraper material | stainless steel |
| Scraper size | 70mm |
| Graduation | 5μm |
Moderner QXD-100 (single-channe) Single-channe Fineness gauge Packing list
Scraper x1, scraper x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHG/T 5173-2017
- AbolishGB/T 12004.5-1992
- ActiveGB/T 13217.5-2023
- ActiveGB/T 42541-2023
- ActiveQB/T 4289-2012
- AbolishTB/T 2260-1991
- ActiveHG/T 5367.1-2018
- ActiveHG/T 5183-2017
- ActiveHG/T 5175-2017
- ActiveHG/T 3369-2003
- ActiveASTM D3794-2022
- ActiveJTJ 275-2000
- ActiveJT/T 821.4-2011
- ActiveJT/T 821.3-2011
- ActiveJT/T 821.2-2011
- ActiveJT/T 821.1-2011
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveGB/T 1724-2019
- ActiveASTM D1316-2020


QXD-100 (single-channe)