Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Mulser> AN> AN AE10 Lab Cut Mulser

      AN AE10 laboratory shear Mulser viscosity up to 10000mPa.s

      The maximum processing viscosity is 10000 mPa.s, the Rotation speed adjustment range is 2000~15000 rpm, the working head is made of stainless steel 316, and the rotor diameter is Φ24 mm.

      Brand
      SKU: NB043934
      China AN
      Model
      Stock
      Loading…
      Price
      $ 1033.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • AN AE10 Lab Cut MulserOverview

        • Specifications
        • Comments
        • FAQs
        AE10
        Lab Cut Mulser
        • AN AE10 laboratory shear Mulser viscosity up to 10000mPa.s
        • AN AE10 laboratory shear Mulser viscosity up to 10000mPa.s Figure 1
        • AN AE10 laboratory shear Mulser viscosity up to 10000mPa.s Figure 2
        The maximum processing viscosity is 10000 mPa.s, the Rotation speed adjustment range is 2000~15000 rpm, the working head is made of stainless steel 316, and the rotor diameter is Φ24 mm.

        Product introduction

        A laboratory shearing emulsifier is a device used in laboratory research and production, mainly for the process of mixing and emulsifying liquids, solids or liquids with solids. This device disperses, emulsifies, and uniformly mixes substances through a high-speed rotating shearing blade or rotor to obtain the desired mixture.

        A laboratory shear emulsifier usually consists of a container (cup, groove, etc.) and a mechanical part equipped with a shear blade or rotor. During operation, the material to be processed is placed into the container to start the mechanical part. The high-speed rotation of the blade or rotor will generate shear force and turbulence, which will quickly disperse and emulsify the material to achieve uniform mixing of the material.

        The AE10 dispersion homogenizer is driven by a high-speed motor and is suitable for crushing and shearing emulsification of particulate materials in low to medium and high viscosity liquids or liquid media. It is especially designed for experiments in small capacity and pasty media.

        Product Features

        • The working head adopts high-quality stainless steel SS316, which has a wide range of experimental applications;

        • The running speed is controlled by a microprocessor, with instant compensation for the speed change caused by load changes and power supply fluctuations, and the constant speed is reliable;

        • Built-in soft start and automatic overload protection ensure full load operation of the experiment;

        • The speed is stepless adjustment, which can meet the experimental correction of the running speed at any time. The digital display speed is intuitive, and the experimental data collection is convenient;

        • Run Timer Control to ensure that the experimental time is effectively controllable.

        Product application

        It is widely used in the laboratory in the fields of pharmaceuticals, food, cosmetics, chemicals, etc., for developing new products, researching formulations, evaluating the performance of mixtures, etc. The laboratory shear emulsifier can simulate the mixing and emulsification process in production, obtain key data from small-scale experiments, optimize the process flow, and ensure product consistency and quality.


        VS

        AN AE10 Lab Cut MulserSpecifications

        LIST VALUE
        Rated Voltage AC220V±10%
        Rated Frequency 50/60HZ
        Input Power 1050 W
        output power 600 W
        Rated torque 38N*cm
        Duty Cycle S1 (continuous)
        Control mode Combined control knob
        Speed range 2000~15000rpm
        Speed regulation mode stepless
        Timer Range 1~1000 min
        Rotation speed display LED
        Rotation speed dynamic detection Yes
        Rotation speed memory function Yes
        Overload protection Yes.
        Protection level IP20
        Work head material Stainless steel 316
        Working head diameter Φ 42 mm
        rotor diameter Φ 24 mm
        stator-rotor clearance 0.5 mm
        Maximum circumferential velocity 18.9 m/s
        immersion depth 38~250 mm
        Stator standard configuration Square hole/long hole/round hole/large round hole
        Process type batch processing
        Processing Capacity 100~20000 ml
        Max. Processing Viscosity 10000 mPa.s
        maximum temperature 180 ℃
        PH value 2~13
        Sterilizing method Chemical wet treatment
        Suspension particle size 15~65μm
        Emulsion particle size 5~30μm
        Environmental temperature Not more than 40 ° C
        Allowable Relative Humidity Not more than 80%
        Dimension 215×310×720 mm
        Machine Weight 9.0 kg

        AN AE10 Lab Cut Mulser Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Our laboratory needs to handle small batches of high-viscosity samples, such as cosmetic pastes. Is there a suitable instrument recommended?
        [A]
        The AE10 Lab Shear Mulser is designed for small volume, high viscosity samples with a maximum processing viscosity of 10,000 mPa.s, and uses high speed shear emulsification technology to quickly and evenly mix pastes to ensure product conformity.
        [Q]
        Does the instrument need to be able to precisely control Rotation speed and timing? Why?
        [A]
        Yes, the AE10 provides stepless speed regulation and 1-1000 minute timing function, which can ensure the repeatability of experimental conditions, such as testing the emulsification effect at different Rotation speeds, avoiding data accuracy due to Rotation speed fluctuations, and improving experimental Reliability.
        [Q]
        Oil-water mixed Mulser, Processing capacity of 1~ 10kg, is it suitable?
        [A]
        This model can be used, as can the AE30.
        [Q]
        Oil-water mixed Mulser, Processing capacity of 1~ 10kg, do you recommend it?
        [A]
        AE10 This Mulser is suitable.
        [Q]
        Oil-water mixed Mulser, Processing capacity of 1~ 10kg, do you recommend it?
        [A]
        AE10 Mulser can.
        AN
        AN AE10 laboratory shear Mulser viscosity up to 10000mPa.s
        Service
        Focus on online sales of Lab Testing Instruments